Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Update BAT and BMS pages #344

Merged
merged 1 commit into from
Mar 26, 2024
Merged
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
132 changes: 132 additions & 0 deletions docs/battery_boards/bat_board/bat_board.md
Original file line number Diff line number Diff line change
@@ -0,0 +1,132 @@
# BAT board

## Introduction

This page describes the `BAT` board, its protocol and its ouput data. Basically, this board is responsible for the management of the data and signals provided by the battery pack in `R1`, `iCub`, and `ergoCub` robots. Moreover, it should be noted that in these robots it is always coupled with the `BMS` board, which is responsible for fine-tuning and managing the battery pack status and described in the [specific BMS page](../bms_board/bms_board.md).


## Firmware

When one aims to update the `BAT` firmware, the correct `.hex` version ought be selected from the `BAT` folder. Specifically, there are two different `BAT` executables:
- `bat.r1.hex`: it addresses R1 robot.
- `bat.hex`: it addresses `iCub` and `ergoCub` robots.

There exist two different versions of the `BAT` FW because the `dcdc_management` phase is done differently between `R1` and `iCub`/`ergoCub`.
Specifically, in `iCub` and `ergoCub` robots, CPU and motors are handled separately, and they can work detached. By contrast, in `R1`, they work always together.
Moreover, these robots do have different battery packs, hence the voltage thresholds are customized in the two FW versions.

In general, as shown in the figures below (illustrating the connection between the `BAT` and `EMS` boards in `ergoCub/SN001` on the left and in the base of `R1/SN003` on the right), the `BAT` can be connected to an `EMS` board through the `CAN` connector devoted to receiving the CAN frames sent out by the `BAT`.

<center>
<table><tr>
<td><img width="500" height="500" src="../assets/bat-2-ems-R1-connection-01.png"/></td>
<td><img width="500" height="500" src="../assets/bat-2-ems-R1-connection-02.png"/></td>
</tr></table>
</center>

## Output data

The data transmitted by the `BAT` board is related to the overall system, whether the robot is on battery or plugged to the external voltage supply.
By contrast, the data transmitted by `BMS` board is specifically related to the battery pack.

Specifically, at the current status of the development (April 2024), the `BAT` board can send the following data (which is then elaborated by fw and sw and sent to a `yarp` port):

- **Input Voltage ($V$)**. This can be either the `Battery pack` voltage or the `Power supply` voltage depending on how the robot is charged. Anyway, it is always the largest value between the two.
- **Total Current absorbed by the system ($A$)** (for the whole robot). This is the total current consumption of the system (the sum of the three currents: 42V HSM (power-supply/battery-pack) + 12V motor + 12V CPU).
- **Battery Pack Charge ($\%$)**. It has a value different from `NaN` if the robot has the `Battery pack` switched enabled.
- **Empty field (NaN)**. Differently from the `BMS` board, the average temperature is not available on the `BAT` board.
- **Battery Pack Status**. Currently, it is a bitmask corresponding to `(DCDC_status_B << 8 ) | DCDC_status_A`. Please see the [Types of data transmitted](#types-of-data-transmitted) for the `DCDC_status_B` and `DCDC_status_A` meanings.

### Communication characteristics

The `BAT` board sends the pieces of information detailed above with a FIFO cycle of `100 ms`. Then, the `EMS` board handles the CAN frames sent by the `BAT`, parses them, and finally forwards them to the higher level of the `yarprobotinterface` at the specific port defined in the configuration files with a frequency of `1 Hz`.
Furthermore, that info is also sent directly from the `BAT` to the display attached to the robot, every `1 s`.

### Types of data transmitted

As mentioned at the end of the [introduction section](#introduction), the CAN frames sent by the `BAT` to the `EMS` and parsed by this latter board are:

- System power info message sent at address `0x620` as:

| Byte | Value | Description |
|:---:|:---:|:---|
| 0 | vBatterydV & 0xFF | LSBs of input voltage (the largest between battery and power supply) |
| 1 | (vBatterydV >> 8) & 0xFF | MSBs of input voltage (the largest between battery and power supply) |
| 2 | iBatterydA & 0xFF | LSBs of the total current absorbed by the system |
| 3 | (iBatterydA >> 8) & 0xFF | MSBs of the total current absorbed by the system |
| 4 | Battery_charge & 0xFF | Byte of the battery pack charge |
| 5 | 0x00 | Not used |
| 6 | 0x00 | Not used (Battery pack temperature not available) |
| 7 | 0x00 | Not used (Battery pack temperature not available) |

- System status message sent at address `0x629` as:

| Byte | Value | Description |
|:---:|:---:|:---|
| 0 | DCDC_status_A & 0xFF | DCDC status A |
| 1 | DCDC_status_B & 0xFF | DCDC status A |
| 2 | 0x00 | Not used |
| 3 | 0x00 | Not used |
| 4 | 0x00 | Not used |
| 5 | 0x00 | Not used |
| 6 | 0x00 | Not used |
| 7 | 0x00 | Not used |

where:

- DCDC_status_A (bits are summed up together):

Position | BIT[7] | BIT[6] | BIT[5] | BIT[4] | BIT[3] | BIT[2] | BIT[1] | BIT[0] |
|:---|:---:|:---:|:---:|:---:|:---:|:---:|:---:|:---:|
Value | V12board | V12board_F | V12motor | V12motor_F | HSM | HSM_PG | HSM_F | HSM_broken |
Description | 12V DCDC board regulator | 12V DCDC board regulator OVERCURRENT fault | 12V DCDC motor regulator | 12V DCDC motor regulator OVERCURRENT fault | Hot Swap Manager | Hot Swap Manager POWER GOOD | Hot Swap Manager OVERCURRENT/OVERVOLTAGE fault | Hot Swap Manager MOSFETs damaged |
Possible status | ON(1)/OFF(0) | OC/NORMAL | ON/OFF | OC/NORMAL| ON/OFF | HSM output voltage stable after transient/HSM output voltage not guaranteed | OC-OV/NORMAL | HSM MOSFETs probably burned/NORMAL |

- DCDC_status_B:

Position | BIT[3] | BIT[2] | BIT[1] | BIT[0] |
|:---|:---:|:---:|:---:|:---:|
Value | HSM_SW_F | HSM_HW_F | PB1_restart | PB2_restart |
Description | OC Fault on the HSM triggered by overcurrent (threshold defined in the FW) | OC Fault on the HSM triggered by FLT Pin on the HSM micro | Restart phase of the push button 1 | Restart phase of the push button 2 |
Possible status | FAULT_OFF(0)/FAULT_ON(1) | FAULT_OFF(0)/FAULT_ON(1) | Start-up phase(1)/stable operation(0) | Start-up phase/stable operation |

- Final status shown at the port is equal to:

`(DCDC_status_B << 8 ) | DCDC_status_A`

Thereby, the end user sees a decimal number on the BAT Display, which can be transformed into BITs and analyzed as described below:

| BIT Position | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| :--- | :---: | :---: | :---: | :---: | :---: | :---: | :---: | :---: | :---: | :---: | :---: | :---: | :---: | :---: | :---: | :---: |
| VALUE | NAN | NAN | NAN | NAN | HSM_SW_F | HSM_HW_F | PB1 | PB2 | V12board | V12board_F | V12motor | V12motor_F | HSM | HSM_PG | HSM_F | HSM_broken |

```console
Example:

If we get 172 as a decimal value, then we will have in bits:

0000 0000 1010 1100

The active bits are thus related to:
- HSM_PG
- HSM
- V12motor
- V12board
```

### Data displayed on the YARP port

The user gets the data from a specific YARP port defined in the configuration file (e.g., on the ergoCub robot it is `/ergocub/battery/bat/data:o`). Here's the format:

- **Input Voltage** to the system, which is displayed in $Volt [V]$.
- **Total current** absorbed by the system is displayed in $Ampere [A]$ (sum of the three currents: 42V HSM + 12V motor + 12V cpu).
- **Battery state of charge** is displayed in $\%$.
- Always NaN (Ready for **Average Temperature** of the Battery Pack in $^\circ C$ if available)
pattacini marked this conversation as resolved.
Show resolved Hide resolved
- **Status** is displayed as a 16-bit integer (only the first 12 bits are valid), whose mapping adheres to the tables above.

!!!warning
The **Average Temperature** field is always shown as `NaN` in the `yarp` port related to the `BAT` data. Differently from the `BMS` board, the `BAT` board cannot provide this piece of information. Therefore, on the firmware side, the CAN message bytes are set to `0x00` and on the software side we are sending `NaN` to the `yarp` port `/ergocub/battery/bat/data:o`.
pattacini marked this conversation as resolved.
Show resolved Hide resolved


Moreover, at start-up, a **DEBUG** message with the initial values of the status (converted to the description strings defined in the static array `s_boards_map_of_battery_alarm_status` in `embObjBattery::updateStatusStringStream()` method) is sent to `yarprobotinterface`.
Then, each time the status changes, a **DEBUG** message is sent to `yarprobotinterface`, which in turn prints out a description only about the values of those bits that have switched.
112 changes: 0 additions & 112 deletions docs/battery_boards/bat_board/bat_protocol.md

This file was deleted.

Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
Loading
Sorry, something went wrong. Reload?
Sorry, we cannot display this file.
Sorry, this file is invalid so it cannot be displayed.
70 changes: 70 additions & 0 deletions docs/battery_boards/bms_board/bms_board.md
Original file line number Diff line number Diff line change
@@ -0,0 +1,70 @@
# BMS board

## Introduction

The Battery Management System (`BMS`) is the board responsible for the correct functioning of the battery pack. Thereby, it prevents the battery from operating outside its safe boundaries, while monitoring its state, and reporting meaningful data to the end user.

The `BMS` is connected to an `EMS` board through the `CAN` connector devoted to receiving the CAN frames sent out by the `BMS` itself. The figures below illustrate the CAN connection between the `BMS` and `EMS` boards on the ergoCub robot platform.

<center>
<table><tr>
<td><img width="500" height="500" src="../assets/bms-2-ems-ergoCub-connection.png"/></td>
<td><img width="500" height="500" src="../assets/ems-2-bms-ergoCub-connection.png"/></td>
</tr></table>
</center>

## Output data

The BMS provides the battery pack information, such as `voltage`, `current`, `state of charge`, `average temperature`, and `error flags`.
Specifically, the `BMS` board can send the following data (which is then elaborated by fw and sw and sent to a `yarp` port):

- **Battery-Pack Voltage in Volt**. This is the `Battery pack` voltage.
- **Total Battery-Pack Current**. This is the total current, with sign, flowing outwards or inwards to the battery pack. Current has a **negative** sign if going out from the battery pack towards the robot and a **positive** sign otherwise, for example when the batteries get charged.
- **Battery Pack Charge in $\%$**. This has a value different from `NaN` if the robot has the `Battery pack` switch enabled.
- **Battery-Pack Temperature in $^\circ C$**. Differently from the `BAT` board, this field is available for `BMS` and it is the **average temperature** of the battery pack.
- **Battery-Pack Status**. Currently, it is a bitmask corresponding to the error flags that can be risen by the `BMS`. Please see the [Types of data transmitted](#types-of-data-transmitted) for the `BMS_STATUS` meanings.

### Communication characteristics

The `BMS` board sends the pieces of information detailed above in polling with a frequency of `1 Hz`. Then, the `EMS` board handles the CAN frames sent by the `BAT`, parses them, and finally forwards them to the higher level of the `yarprobotinterface` at the specific port defined in the configuration files with a default frequency of `1 Hz`.

### Types of data transmitted

Referring to the current `CAN` protocol of the `BMS`, the frames that the `EMS` manages are the following:

- Battery pack info message sent at address `0x620` as:

| Bytes | Value | Description |
|:---:|:---:|:---|
| 0-1 | Battery-pack voltage in deciVolt | battery pack voltage as unsigned short int |
| 2-3 | Instantaneous Current in deciAmpere | battery pack instantaneous current as short int |
| 4-5 | State of Charge in % | battery pack state of charge as unsigned short int |
| 6-7 | Average Temperature in Celsius | batter pack average temperature as unsigned short int |

- Battery pack status message sent at address `0x628` in the byte0 as:

| Bit | Value | Description |
|:---:|:---:|:---|
| 0 | [0 - 1] | battery pack low voltage error |
| 1 | [0 - 1] | battery pack high voltage error |
| 2 | [0 - 1] | battery pack overcurrent in discharge |
| 3 | [0 - 1] | battery pack overcurrent in charge |
| 4 | [0 - 1] | battery pack low state of charge |
| 5 | [0 - 1] | battery pack low temperature |
| 6 | [0 - 1] | battery pack high temperature |

!!! note
Specifically to this message, only the `general alarm status` of the battery pack is sent out, stored at `byte 0`. This identifies the single or multiple causes that trigger the alarm status on `BMS`. Note that, if an alarm is raised, it remains engaged for **1 minute**, even if the alarm is cleared.

### Data displayed on the YARP port

The user gets the data from the specific YARP port defined in the configuration file (e.g., on the ergoCub robot it is `/ergocub/battery/bms/data:o`). Here's the format:

- **Battery-Pack Voltage**, which is displayed in $Volt [V]$.
- **Instantaneous current**, flowing inwards/outwards the battery pack, which is displayed in $Ampere [A]$.
- **Battery-Pack state of charge**, which is displayed in $\%$.
- **Average Temperature** of the battery pack, which is displayed in $^\circ C$.
- **Battery-Pack Status** is displayed as a 16-bit integer (only the first 7 bits are valid), whose mapping adheres to the tables above.

Moreover, at start-up, a **DEBUG** message with the initial values of the status (converted to the description strings defined in the static array `s_boards_map_of_battery_alarm_status` in `embObjBattery::updateStatusStringStream()` method) is sent to `yarprobotinterface`.
Then, each time the status changes, a **DEBUG** message is sent to `yarprobotinterface`, which in turn prints out a description only about the values of those bits that have switched.