8 changes: 7 additions & 1 deletion docs/release_notes.rst
Original file line number Diff line number Diff line change
Expand Up @@ -5,13 +5,19 @@ Release Notes
.. Upcoming Release
.. ================

* added water-sourced heat pumps based on upper uncertainty bounds from DEA technology catalogue ("40 Comp. hp, seawater 20 MW")

* **WARNING**: Costs for central geothermal heating are split into `central geothermal heat source` and `central geothermal-sourced heat pump`. Make sure to use the costs of both for full systems!

* added geothermal district heating as `central geothermal-sourced heat pump` and `central goethermal heat source` based on DEA technology catalogue ("45.1.a Geothermal DH, 1200m, E")

* added Pyrolysis for biochar

* fixed unit formatting in DEA technology data sheets 105 (slow pyrolysis)

* fixed DEA technology data sheet name for central water tank storage to point to actual PTES data

* added geothermal district heating as `central geothermal-sourced heat pump` based on DEA technology catalogue ("45.1.a Geothermal DH, 1200m, E")
* Fix minor issues in the code

* fix minor issues in the code

Expand Down
18 changes: 16 additions & 2 deletions outputs/costs_2020.csv
Original file line number Diff line number Diff line change
Expand Up @@ -650,6 +650,11 @@ central coal CHP,c_v,0.15,50oC/100oC,"Danish Energy Agency, technology_data_for_
central coal CHP,efficiency,0.485,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","01 Coal CHP: Electricity efficiency, condensation mode, net",2015.0
central coal CHP,investment,2010.6211,EUR/kW,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",01 Coal CHP: Nominal investment,2015.0
central coal CHP,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",01 Coal CHP: Technical lifetime,2015.0
central excess-heat-sourced heat pump,FOM,0.3003,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Fixed O&M",2015.0
central excess-heat-sourced heat pump,VOM,1.7884,EUR/MWh,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Variable O&M",2015.0
central excess-heat-sourced heat pump,efficiency,5.1,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Total efficiency , net, annual average",2015.0
central excess-heat-sourced heat pump,investment,704.7435,EUR/kW,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Specific investment",2015.0
central excess-heat-sourced heat pump,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Technical lifetime",2015.0
central gas CHP,FOM,3.3051,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","04 Gas turb. simple cycle, L: Fixed O&M",2015.0
central gas CHP,VOM,4.6562,EUR/MWh,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","04 Gas turb. simple cycle, L: Variable O&M",2015.0
central gas CHP,c_b,0.96,50oC/100oC,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","04 Gas turb. simple cycle, L: Cb coefficient",2015.0
Expand All @@ -669,9 +674,13 @@ central gas boiler,VOM,1.164,EUR/MWh_th,"Danish Energy Agency, technology_data_f
central gas boiler,efficiency,1.03,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","44 Natural Gas DH Only: Total efficiency , net, annual average",2015.0
central gas boiler,investment,63.4933,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",44 Natural Gas DH Only: Nominal investment,2015.0
central gas boiler,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",44 Natural Gas DH Only: Technical lifetime,2015.0
central geothermal-sourced heat pump,FOM,0.8328,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0
central geothermal heat source,FOM,1.4715,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0
central geothermal heat source,VOM,6.0281,EUR/MWh,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Variable O&M",2015.0
central geothermal heat source,investment,1625.2908,EUR/kW,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0
central geothermal heat source,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Technical lifetime",2015.0
central geothermal-sourced heat pump,FOM,3.3935,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0
central geothermal-sourced heat pump,VOM,6.0281,EUR/MWh_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Variable O&M",2015.0
central geothermal-sourced heat pump,investment,2871.7979,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0
central geothermal-sourced heat pump,investment,704.7435,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0
amos-schledorn marked this conversation as resolved.
Show resolved Hide resolved
central geothermal-sourced heat pump,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Technical lifetime",2015.0
central ground-sourced heat pump,FOM,0.3546,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Fixed O&M",2015.0
central ground-sourced heat pump,VOM,1.0392,EUR/MWh_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Variable O&M",2015.0
Expand Down Expand Up @@ -722,6 +731,11 @@ central water pit storage,lifetime,20.0,years,"Danish Energy Agency, technology_
central water tank storage,FOM,0.2901,%/year,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Fixed O&M,2015.0
central water tank storage,investment,3.1374,EUR/kWhCapacity,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Specific investment,2015.0
central water tank storage,lifetime,40.0,years,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Technical lifetime,2015.0
central water-sourced heat pump,FOM,0.5,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Fixed O&M",2015.0
central water-sourced heat pump,VOM,1.8942,EUR/MWh,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Variable O&M",2015.0
central water-sourced heat pump,efficiency,3.78,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Total efficiency , net, annual average",2015.0
central water-sourced heat pump,investment,1058.2216,EUR/kW,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Specific investment",2015.0
central water-sourced heat pump,lifetime,40.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Technical lifetime",2015.0
clean water tank storage,FOM,2.0,%/year,"Caldera et al 2016: Local cost of seawater RO desalination based on solar PV and windenergy: A global estimate. (https://doi.org/10.1016/j.desal.2016.02.004), Table 1.",,
clean water tank storage,investment,69.1286,EUR/m^3-H2O,"Caldera et al 2016: Local cost of seawater RO desalination based on solar PV and windenergy: A global estimate. (https://doi.org/10.1016/j.desal.2016.02.004), Table 1.",,2013.0
clean water tank storage,lifetime,30.0,years,"Caldera et al 2016: Local cost of seawater RO desalination based on solar PV and windenergy: A global estimate. (https://doi.org/10.1016/j.desal.2016.02.004), Table 1.",,
Expand Down
18 changes: 16 additions & 2 deletions outputs/costs_2025.csv
Original file line number Diff line number Diff line change
Expand Up @@ -650,6 +650,11 @@ central coal CHP,c_v,0.15,50oC/100oC,"Danish Energy Agency, technology_data_for_
central coal CHP,efficiency,0.5025,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","01 Coal CHP: Electricity efficiency, condensation mode, net",2015.0
central coal CHP,investment,1989.708,EUR/kW,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",01 Coal CHP: Nominal investment,2015.0
central coal CHP,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",01 Coal CHP: Technical lifetime,2015.0
central excess-heat-sourced heat pump,FOM,0.3003,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Fixed O&M",2015.0
central excess-heat-sourced heat pump,VOM,1.7884,EUR/MWh,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Variable O&M",2015.0
central excess-heat-sourced heat pump,efficiency,5.2,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Total efficiency , net, annual average",2015.0
central excess-heat-sourced heat pump,investment,704.7435,EUR/kW,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Specific investment",2015.0
central excess-heat-sourced heat pump,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, excess heat 10 MW: Technical lifetime",2015.0
central gas CHP,FOM,3.313,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","04 Gas turb. simple cycle, L: Fixed O&M",2015.0
central gas CHP,VOM,4.5504,EUR/MWh,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","04 Gas turb. simple cycle, L: Variable O&M",2015.0
central gas CHP,c_b,0.98,50oC/100oC,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","04 Gas turb. simple cycle, L: Cb coefficient",2015.0
Expand All @@ -669,9 +674,13 @@ central gas boiler,VOM,1.1111,EUR/MWh_th,"Danish Energy Agency, technology_data_
central gas boiler,efficiency,1.035,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","44 Natural Gas DH Only: Total efficiency , net, annual average",2015.0
central gas boiler,investment,58.2022,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",44 Natural Gas DH Only: Nominal investment,2015.0
central gas boiler,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx",44 Natural Gas DH Only: Technical lifetime,2015.0
central geothermal-sourced heat pump,FOM,0.8253,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0
central geothermal heat source,FOM,1.4691,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0
central geothermal heat source,VOM,6.0453,EUR/MWh,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Variable O&M",2015.0
central geothermal heat source,investment,1577.4881,EUR/kW,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0
central geothermal heat source,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Technical lifetime",2015.0
central geothermal-sourced heat pump,FOM,3.2884,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Fixed O&M",2015.0
central geothermal-sourced heat pump,VOM,6.0453,EUR/MWh_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Variable O&M",2015.0
central geothermal-sourced heat pump,investment,2808.061,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0
central geothermal-sourced heat pump,investment,704.7435,EUR/kW_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Nominal investment",2015.0
central geothermal-sourced heat pump,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","45.1.a Geothermal DH, 1200m, E: Technical lifetime",2015.0
central ground-sourced heat pump,FOM,0.3733,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Fixed O&M",2015.0
central ground-sourced heat pump,VOM,1.183,EUR/MWh_th,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Absorption heat pump, DH: Variable O&M",2015.0
Expand Down Expand Up @@ -722,6 +731,11 @@ central water pit storage,lifetime,22.5,years,"Danish Energy Agency, technology_
central water tank storage,FOM,0.2901,%/year,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Fixed O&M,2015.0
central water tank storage,investment,3.1374,EUR/kWhCapacity,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Specific investment,2015.0
central water tank storage,lifetime,40.0,years,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Technical lifetime,2015.0
central water-sourced heat pump,FOM,0.5,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Fixed O&M",2015.0
central water-sourced heat pump,VOM,1.7884,EUR/MWh,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Variable O&M",2015.0
central water-sourced heat pump,efficiency,3.8,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Total efficiency , net, annual average",2015.0
central water-sourced heat pump,investment,1058.2216,EUR/kW,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Specific investment",2015.0
central water-sourced heat pump,lifetime,40.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Technical lifetime",2015.0
clean water tank storage,FOM,2.0,%/year,"Caldera et al 2016: Local cost of seawater RO desalination based on solar PV and windenergy: A global estimate. (https://doi.org/10.1016/j.desal.2016.02.004), Table 1.",,
clean water tank storage,investment,69.1286,EUR/m^3-H2O,"Caldera et al 2016: Local cost of seawater RO desalination based on solar PV and windenergy: A global estimate. (https://doi.org/10.1016/j.desal.2016.02.004), Table 1.",,2013.0
clean water tank storage,lifetime,30.0,years,"Caldera et al 2016: Local cost of seawater RO desalination based on solar PV and windenergy: A global estimate. (https://doi.org/10.1016/j.desal.2016.02.004), Table 1.",,
Expand Down
Loading