Skip to content

Commit

Permalink
Ltes mod (#159)
Browse files Browse the repository at this point in the history
* Add PTES technology with correct parameters, reassign TTES parameters

* Add PTES, reassign TTES param

* Add energy to power ratio calculation for ltes

* Add energy to power ratio calculation for ltes

* Update release notes

* improve readability

* updating charging efficiency LTES

* Update decentral water storage to DEA data and include energy to power ratio

* minor changes to enhance readability

* minor changes to enhance readability

* small changes - ready for PR
  • Loading branch information
TomKae00 authored Dec 13, 2024
1 parent 8d0c8bf commit 0abf81f
Show file tree
Hide file tree
Showing 10 changed files with 144 additions and 70 deletions.
4 changes: 3 additions & 1 deletion docs/release_notes.rst
Original file line number Diff line number Diff line change
Expand Up @@ -23,7 +23,9 @@ Release Notes

* added iron-air battery cost data from Form Energy

* added energy to power ratio for central water pit storage and central water tank storage
* update decentral water tank storage data from PyPSA to DEA sources

* added energy to power ratio for central water pit storage and central/decentral water tank storage

Technology-Data 0.9.2 (30 August 2024)
======================================
Expand Down
2 changes: 1 addition & 1 deletion latex_tables/tables_in_latex.py
Original file line number Diff line number Diff line change
Expand Up @@ -142,7 +142,7 @@
'electric boiler steam': 'electric boiler steam',
'gas boiler steam': 'gas boiler steam',
'solid biomass boiler steam': 'solid biomass boiler steam',
'methanolisation': 'methanolisation'
'methanolisation': 'methanolisation',
'Compressed-Air-Adiabatic-bicharger': 'Compressed-Air-Adiabatic-bicharger',
'Compressed-Air-Adiabatic-store': 'Compressed-Air-Adiabatic-store',
'Concrete-charger': 'Concrete-charger',
Expand Down
18 changes: 12 additions & 6 deletions outputs/costs_2020.csv
Original file line number Diff line number Diff line change
Expand Up @@ -725,10 +725,14 @@ central solid biomass CHP powerboost CC,efficiency,0.2689,per unit,"Danish Energ
central solid biomass CHP powerboost CC,efficiency-heat,0.8255,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","09a Wood Chips, Large 50 degree: Heat efficiency, net, annual average",2015.0
central solid biomass CHP powerboost CC,investment,3740.4387,EUR/kW_e,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","09a Wood Chips, Large 50 degree: Nominal investment ",2015.0
central solid biomass CHP powerboost CC,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","09a Wood Chips, Large 50 degree: Technical lifetime",2015.0
central water pit charger,efficiency,1.0,per unit,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2015.0
central water pit discharger,efficiency,1.0,per unit,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",: Discharger efficiency,2015.0
central water pit storage,FOM,0.5176,%/year,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Fixed O&M,2015.0
central water pit storage,energy to power ratio,150.0,h,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Ratio between energy storage and input capacity,2015.0
central water pit storage,investment,0.6133,EUR/kWhCapacity,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Specific investment,2015.0
central water pit storage,lifetime,20.0,years,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Technical lifetime,2015.0
central water tank charger,efficiency,1.0,per unit,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2015.0
central water tank discharger,efficiency,1.0,per unit,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",: Discharger efficiency,2015.0
central water tank storage,FOM,0.2901,%/year,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Fixed O&M,2015.0
central water tank storage,energy to power ratio,60.3448,h,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Ratio between energy storage and input capacity,2015.0
central water tank storage,investment,3.1374,EUR/kWhCapacity,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Specific investment,2015.0
Expand Down Expand Up @@ -791,10 +795,14 @@ decentral solar thermal,FOM,1.3,%/year,HP, from old pypsa cost assumptions,2015.
decentral solar thermal,discount rate,0.04,per unit,Palzer thesis, from old pypsa cost assumptions,2015.0
decentral solar thermal,investment,285719.8393,EUR/1000m2,HP, from old pypsa cost assumptions,2015.0
decentral solar thermal,lifetime,20.0,years,HP, from old pypsa cost assumptions,2015.0
decentral water tank charger,efficiency,1.0,per unit,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2015.0
decentral water tank discharger,efficiency,1.0,per unit,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",: Discharger efficiency,2015.0
decentral water tank storage,FOM,1.0,%/year,HP, from old pypsa cost assumptions,2015.0
decentral water tank storage,VOM,0.7408,EUR/MWh,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",142 Small scale hot water tank: Variable O&M,2015.0
decentral water tank storage,discount rate,0.04,per unit,Palzer thesis, from old pypsa cost assumptions,2015.0
decentral water tank storage,investment,19.446,EUR/kWh,IWES Interaktion, from old pypsa cost assumptions,2015.0
decentral water tank storage,lifetime,20.0,years,HP, from old pypsa cost assumptions,2015.0
decentral water tank storage,energy to power ratio,0.15,h,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",142 Small scale hot water tank: Ratio between energy storage and input capacity,2015.0
decentral water tank storage,investment,433.8709,EUR/kWh,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",142 Small scale hot water tank: Specific investment,2015.0
decentral water tank storage,lifetime,30.0,years,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",142 Small scale hot water tank: Technical lifetime,2015.0
digestible biomass,fuel,17.0611,EUR/MWh_th,"JRC ENSPRESO ca avg for MINBIOAGRW1, ENS_Ref for 2040",,2010.0
digestible biomass to hydrogen,FOM,4.25,%/year,"Zech et.al. DBFZ Report Nr. 19. Hy-NOW - Evaluierung der Verfahren und Technologien für die Bereitstellung von Wasserstoff auf Basis von Biomasse, DBFZ, 2014",,
digestible biomass to hydrogen,capture rate,0.9,per unit,Assumption based on doi:10.1016/j.biombioe.2015.01.006,,
Expand Down Expand Up @@ -1091,7 +1099,5 @@ waste CHP CC,efficiency,0.2021,per unit,"Danish Energy Agency, technology_data_f
waste CHP CC,efficiency-heat,0.7635,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","08 WtE CHP, Large, 50 degree: Heat efficiency, net, annual average",2015.0
waste CHP CC,investment,9077.1074,EUR/kW_e,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","08 WtE CHP, Large, 50 degree: Nominal investment ",2015.0
waste CHP CC,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","08 WtE CHP, Large, 50 degree: Technical lifetime",2015.0
water pit charger,efficiency,0.8367,per unit,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",: efficiency from sqr(Round trip efficiency),2015.0
water pit discharger,efficiency,0.8367,per unit,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",: efficiency from sqr(Round trip efficiency),2015.0
water tank charger,efficiency,0.9899,per unit,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",: efficiency from sqr(Round trip efficiency),2015.0
water tank discharger,efficiency,0.9899,per unit,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",: efficiency from sqr(Round trip efficiency),2015.0
water tank charger,efficiency,0.9,per unit,HP, from old pypsa cost assumptions,2015.0
water tank discharger,efficiency,0.9,per unit,HP, from old pypsa cost assumptions,2015.0
18 changes: 12 additions & 6 deletions outputs/costs_2025.csv
Original file line number Diff line number Diff line change
Expand Up @@ -725,10 +725,14 @@ central solid biomass CHP powerboost CC,efficiency,0.2694,per unit,"Danish Energ
central solid biomass CHP powerboost CC,efficiency-heat,0.825,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","09a Wood Chips, Large 50 degree: Heat efficiency, net, annual average",2015.0
central solid biomass CHP powerboost CC,investment,3642.4702,EUR/kW_e,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","09a Wood Chips, Large 50 degree: Nominal investment ",2015.0
central solid biomass CHP powerboost CC,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","09a Wood Chips, Large 50 degree: Technical lifetime",2015.0
central water pit charger,efficiency,1.0,per unit,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2015.0
central water pit discharger,efficiency,1.0,per unit,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",: Discharger efficiency,2015.0
central water pit storage,FOM,0.5338,%/year,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Fixed O&M,2015.0
central water pit storage,energy to power ratio,150.0,h,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Ratio between energy storage and input capacity,2015.0
central water pit storage,investment,0.5947,EUR/kWhCapacity,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Specific investment,2015.0
central water pit storage,lifetime,22.5,years,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Technical lifetime,2015.0
central water tank charger,efficiency,1.0,per unit,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2015.0
central water tank discharger,efficiency,1.0,per unit,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",: Discharger efficiency,2015.0
central water tank storage,FOM,0.2901,%/year,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Fixed O&M,2015.0
central water tank storage,energy to power ratio,60.3448,h,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Ratio between energy storage and input capacity,2015.0
central water tank storage,investment,3.1374,EUR/kWhCapacity,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Specific investment,2015.0
Expand Down Expand Up @@ -791,10 +795,14 @@ decentral solar thermal,FOM,1.3,%/year,HP, from old pypsa cost assumptions,2015.
decentral solar thermal,discount rate,0.04,per unit,Palzer thesis, from old pypsa cost assumptions,2015.0
decentral solar thermal,investment,285719.8393,EUR/1000m2,HP, from old pypsa cost assumptions,2015.0
decentral solar thermal,lifetime,20.0,years,HP, from old pypsa cost assumptions,2015.0
decentral water tank charger,efficiency,1.0,per unit,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2015.0
decentral water tank discharger,efficiency,1.0,per unit,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",: Discharger efficiency,2015.0
decentral water tank storage,FOM,1.0,%/year,HP, from old pypsa cost assumptions,2015.0
decentral water tank storage,VOM,0.8995,EUR/MWh,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",142 Small scale hot water tank: Variable O&M,2015.0
decentral water tank storage,discount rate,0.04,per unit,Palzer thesis, from old pypsa cost assumptions,2015.0
decentral water tank storage,investment,19.446,EUR/kWh,IWES Interaktion, from old pypsa cost assumptions,2015.0
decentral water tank storage,lifetime,20.0,years,HP, from old pypsa cost assumptions,2015.0
decentral water tank storage,energy to power ratio,0.15,h,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",142 Small scale hot water tank: Ratio between energy storage and input capacity,2015.0
decentral water tank storage,investment,433.8709,EUR/kWh,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",142 Small scale hot water tank: Specific investment,2015.0
decentral water tank storage,lifetime,30.0,years,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",142 Small scale hot water tank: Technical lifetime,2015.0
digestible biomass,fuel,17.0611,EUR/MWh_th,"JRC ENSPRESO ca avg for MINBIOAGRW1, ENS_Ref for 2040",,2010.0
digestible biomass to hydrogen,FOM,4.25,%/year,"Zech et.al. DBFZ Report Nr. 19. Hy-NOW - Evaluierung der Verfahren und Technologien für die Bereitstellung von Wasserstoff auf Basis von Biomasse, DBFZ, 2014",,
digestible biomass to hydrogen,capture rate,0.9,per unit,Assumption based on doi:10.1016/j.biombioe.2015.01.006,,
Expand Down Expand Up @@ -1091,7 +1099,5 @@ waste CHP CC,efficiency,0.2051,per unit,"Danish Energy Agency, technology_data_f
waste CHP CC,efficiency-heat,0.7627,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","08 WtE CHP, Large, 50 degree: Heat efficiency, net, annual average",2015.0
waste CHP CC,investment,8829.8509,EUR/kW_e,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","08 WtE CHP, Large, 50 degree: Nominal investment ",2015.0
waste CHP CC,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","08 WtE CHP, Large, 50 degree: Technical lifetime",2015.0
water pit charger,efficiency,0.8367,per unit,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",: efficiency from sqr(Round trip efficiency),2015.0
water pit discharger,efficiency,0.8367,per unit,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",: efficiency from sqr(Round trip efficiency),2015.0
water tank charger,efficiency,0.9899,per unit,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",: efficiency from sqr(Round trip efficiency),2015.0
water tank discharger,efficiency,0.9899,per unit,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",: efficiency from sqr(Round trip efficiency),2015.0
water tank charger,efficiency,0.9,per unit,HP, from old pypsa cost assumptions,2015.0
water tank discharger,efficiency,0.9,per unit,HP, from old pypsa cost assumptions,2015.0
18 changes: 12 additions & 6 deletions outputs/costs_2030.csv
Original file line number Diff line number Diff line change
Expand Up @@ -725,10 +725,14 @@ central solid biomass CHP powerboost CC,efficiency,0.2699,per unit,"Danish Energ
central solid biomass CHP powerboost CC,efficiency-heat,0.8245,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","09a Wood Chips, Large 50 degree: Heat efficiency, net, annual average",2015.0
central solid biomass CHP powerboost CC,investment,3544.5017,EUR/kW_e,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","09a Wood Chips, Large 50 degree: Nominal investment ",2015.0
central solid biomass CHP powerboost CC,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","09a Wood Chips, Large 50 degree: Technical lifetime",2015.0
central water pit charger,efficiency,1.0,per unit,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2015.0
central water pit discharger,efficiency,1.0,per unit,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",: Discharger efficiency,2015.0
central water pit storage,FOM,0.551,%/year,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Fixed O&M,2015.0
central water pit storage,energy to power ratio,150.0,h,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Ratio between energy storage and input capacity,2015.0
central water pit storage,investment,0.5761,EUR/kWhCapacity,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Specific investment,2015.0
central water pit storage,lifetime,25.0,years,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Technical lifetime,2015.0
central water tank charger,efficiency,1.0,per unit,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2015.0
central water tank discharger,efficiency,1.0,per unit,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",: Discharger efficiency,2015.0
central water tank storage,FOM,0.2901,%/year,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Fixed O&M,2015.0
central water tank storage,energy to power ratio,60.3448,h,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Ratio between energy storage and input capacity,2015.0
central water tank storage,investment,3.1374,EUR/kWhCapacity,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Specific investment,2015.0
Expand Down Expand Up @@ -791,10 +795,14 @@ decentral solar thermal,FOM,1.3,%/year,HP, from old pypsa cost assumptions,2015.
decentral solar thermal,discount rate,0.04,per unit,Palzer thesis, from old pypsa cost assumptions,2015.0
decentral solar thermal,investment,285719.8393,EUR/1000m2,HP, from old pypsa cost assumptions,2015.0
decentral solar thermal,lifetime,20.0,years,HP, from old pypsa cost assumptions,2015.0
decentral water tank charger,efficiency,1.0,per unit,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",: Charger efficiency,2015.0
decentral water tank discharger,efficiency,1.0,per unit,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",: Discharger efficiency,2015.0
decentral water tank storage,FOM,1.0,%/year,HP, from old pypsa cost assumptions,2015.0
decentral water tank storage,VOM,1.0582,EUR/MWh,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",142 Small scale hot water tank: Variable O&M,2015.0
decentral water tank storage,discount rate,0.04,per unit,Palzer thesis, from old pypsa cost assumptions,2015.0
decentral water tank storage,investment,19.446,EUR/kWh,IWES Interaktion, from old pypsa cost assumptions,2015.0
decentral water tank storage,lifetime,20.0,years,HP, from old pypsa cost assumptions,2015.0
decentral water tank storage,energy to power ratio,0.15,h,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",142 Small scale hot water tank: Ratio between energy storage and input capacity,2015.0
decentral water tank storage,investment,433.8709,EUR/kWh,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",142 Small scale hot water tank: Specific investment,2015.0
decentral water tank storage,lifetime,30.0,years,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",142 Small scale hot water tank: Technical lifetime,2015.0
digestible biomass,fuel,17.0611,EUR/MWh_th,"JRC ENSPRESO ca avg for MINBIOAGRW1, ENS_Ref for 2040",,2010.0
digestible biomass to hydrogen,FOM,4.25,%/year,"Zech et.al. DBFZ Report Nr. 19. Hy-NOW - Evaluierung der Verfahren und Technologien für die Bereitstellung von Wasserstoff auf Basis von Biomasse, DBFZ, 2014",,
digestible biomass to hydrogen,capture rate,0.9,per unit,Assumption based on doi:10.1016/j.biombioe.2015.01.006,,
Expand Down Expand Up @@ -1091,7 +1099,5 @@ waste CHP CC,efficiency,0.2081,per unit,"Danish Energy Agency, technology_data_f
waste CHP CC,efficiency-heat,0.7619,per unit,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","08 WtE CHP, Large, 50 degree: Heat efficiency, net, annual average",2015.0
waste CHP CC,investment,8582.5944,EUR/kW_e,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","08 WtE CHP, Large, 50 degree: Nominal investment ",2015.0
waste CHP CC,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","08 WtE CHP, Large, 50 degree: Technical lifetime",2015.0
water pit charger,efficiency,0.8367,per unit,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",: efficiency from sqr(Round trip efficiency),2015.0
water pit discharger,efficiency,0.8367,per unit,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",: efficiency from sqr(Round trip efficiency),2015.0
water tank charger,efficiency,0.9899,per unit,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",: efficiency from sqr(Round trip efficiency),2015.0
water tank discharger,efficiency,0.9899,per unit,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",: efficiency from sqr(Round trip efficiency),2015.0
water tank charger,efficiency,0.9,per unit,HP, from old pypsa cost assumptions,2015.0
water tank discharger,efficiency,0.9,per unit,HP, from old pypsa cost assumptions,2015.0
Loading

0 comments on commit 0abf81f

Please sign in to comment.