add energy power ratio ltes (#157)
Browse files Browse the repository at this point in the history
* Add PTES technology with correct parameters, reassign TTES parameters

* Add PTES, reassign TTES param

* Add energy to power ratio calculation for ltes

* Add energy to power ratio calculation for ltes

* Update release notes

* improve readability
  • Loading branch information
TomKae00 authored Nov 26, 2024
1 parent a1d7ca7 commit 8d0c8bf
Show file tree
Hide file tree
Showing 9 changed files with 44 additions and 3 deletions.
1 change: 1 addition & 0 deletions docs/release_notes.rst
Original file line number Diff line number Diff line change
Expand Up @@ -23,6 +23,7 @@ Release Notes

* added iron-air battery cost data from Form Energy

* added energy to power ratio for central water pit storage and central water tank storage

Technology-Data 0.9.2 (30 August 2024)
======================================
Expand Down
2 changes: 2 additions & 0 deletions outputs/costs_2020.csv
Original file line number Diff line number Diff line change
Expand Up @@ -726,9 +726,11 @@ central solid biomass CHP powerboost CC,efficiency-heat,0.8255,per unit,"Danish
central solid biomass CHP powerboost CC,investment,3740.4387,EUR/kW_e,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","09a Wood Chips, Large 50 degree: Nominal investment ",2015.0
central solid biomass CHP powerboost CC,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","09a Wood Chips, Large 50 degree: Technical lifetime",2015.0
central water pit storage,FOM,0.5176,%/year,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Fixed O&M,2015.0
central water pit storage,energy to power ratio,150.0,h,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Ratio between energy storage and input capacity,2015.0
central water pit storage,investment,0.6133,EUR/kWhCapacity,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Specific investment,2015.0
central water pit storage,lifetime,20.0,years,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Technical lifetime,2015.0
central water tank storage,FOM,0.2901,%/year,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Fixed O&M,2015.0
central water tank storage,energy to power ratio,60.3448,h,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Ratio between energy storage and input capacity,2015.0
central water tank storage,investment,3.1374,EUR/kWhCapacity,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Specific investment,2015.0
central water tank storage,lifetime,40.0,years,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Technical lifetime,2015.0
central water-sourced heat pump,FOM,0.5,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Fixed O&M",2015.0
Expand Down
2 changes: 2 additions & 0 deletions outputs/costs_2025.csv
Original file line number Diff line number Diff line change
Expand Up @@ -726,9 +726,11 @@ central solid biomass CHP powerboost CC,efficiency-heat,0.825,per unit,"Danish E
central solid biomass CHP powerboost CC,investment,3642.4702,EUR/kW_e,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","09a Wood Chips, Large 50 degree: Nominal investment ",2015.0
central solid biomass CHP powerboost CC,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","09a Wood Chips, Large 50 degree: Technical lifetime",2015.0
central water pit storage,FOM,0.5338,%/year,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Fixed O&M,2015.0
central water pit storage,energy to power ratio,150.0,h,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Ratio between energy storage and input capacity,2015.0
central water pit storage,investment,0.5947,EUR/kWhCapacity,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Specific investment,2015.0
central water pit storage,lifetime,22.5,years,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Technical lifetime,2015.0
central water tank storage,FOM,0.2901,%/year,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Fixed O&M,2015.0
central water tank storage,energy to power ratio,60.3448,h,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Ratio between energy storage and input capacity,2015.0
central water tank storage,investment,3.1374,EUR/kWhCapacity,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Specific investment,2015.0
central water tank storage,lifetime,40.0,years,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Technical lifetime,2015.0
central water-sourced heat pump,FOM,0.5,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Fixed O&M",2015.0
Expand Down
2 changes: 2 additions & 0 deletions outputs/costs_2030.csv
Original file line number Diff line number Diff line change
Expand Up @@ -726,9 +726,11 @@ central solid biomass CHP powerboost CC,efficiency-heat,0.8245,per unit,"Danish
central solid biomass CHP powerboost CC,investment,3544.5017,EUR/kW_e,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","09a Wood Chips, Large 50 degree: Nominal investment ",2015.0
central solid biomass CHP powerboost CC,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","09a Wood Chips, Large 50 degree: Technical lifetime",2015.0
central water pit storage,FOM,0.551,%/year,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Fixed O&M,2015.0
central water pit storage,energy to power ratio,150.0,h,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Ratio between energy storage and input capacity,2015.0
central water pit storage,investment,0.5761,EUR/kWhCapacity,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Specific investment,2015.0
central water pit storage,lifetime,25.0,years,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Technical lifetime,2015.0
central water tank storage,FOM,0.2901,%/year,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Fixed O&M,2015.0
central water tank storage,energy to power ratio,60.3448,h,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Ratio between energy storage and input capacity,2015.0
central water tank storage,investment,3.1374,EUR/kWhCapacity,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Specific investment,2015.0
central water tank storage,lifetime,40.0,years,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Technical lifetime,2015.0
central water-sourced heat pump,FOM,0.5,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Fixed O&M",2015.0
Expand Down
2 changes: 2 additions & 0 deletions outputs/costs_2035.csv
Original file line number Diff line number Diff line change
Expand Up @@ -726,9 +726,11 @@ central solid biomass CHP powerboost CC,efficiency-heat,0.8257,per unit,"Danish
central solid biomass CHP powerboost CC,investment,3493.3,EUR/kW_e,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","09a Wood Chips, Large 50 degree: Nominal investment ",2015.0
central solid biomass CHP powerboost CC,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","09a Wood Chips, Large 50 degree: Technical lifetime",2015.0
central water pit storage,FOM,0.5714,%/year,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Fixed O&M,2015.0
central water pit storage,energy to power ratio,150.0,h,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Ratio between energy storage and input capacity,2015.0
central water pit storage,investment,0.5556,EUR/kWhCapacity,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Specific investment,2015.0
central water pit storage,lifetime,25.0,years,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Technical lifetime,2015.0
central water tank storage,FOM,0.2901,%/year,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Fixed O&M,2015.0
central water tank storage,energy to power ratio,60.3448,h,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Ratio between energy storage and input capacity,2015.0
central water tank storage,investment,3.1374,EUR/kWhCapacity,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Specific investment,2015.0
central water tank storage,lifetime,40.0,years,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Technical lifetime,2015.0
central water-sourced heat pump,FOM,0.5,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Fixed O&M",2015.0
Expand Down
2 changes: 2 additions & 0 deletions outputs/costs_2040.csv
Original file line number Diff line number Diff line change
Expand Up @@ -726,9 +726,11 @@ central solid biomass CHP powerboost CC,efficiency-heat,0.8269,per unit,"Danish
central solid biomass CHP powerboost CC,investment,3442.0984,EUR/kW_e,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","09a Wood Chips, Large 50 degree: Nominal investment ",2015.0
central solid biomass CHP powerboost CC,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","09a Wood Chips, Large 50 degree: Technical lifetime",2015.0
central water pit storage,FOM,0.5934,%/year,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Fixed O&M,2015.0
central water pit storage,energy to power ratio,150.0,h,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Ratio between energy storage and input capacity,2015.0
central water pit storage,investment,0.535,EUR/kWhCapacity,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Specific investment,2015.0
central water pit storage,lifetime,25.0,years,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Technical lifetime,2015.0
central water tank storage,FOM,0.2901,%/year,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Fixed O&M,2015.0
central water tank storage,energy to power ratio,60.3448,h,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Ratio between energy storage and input capacity,2015.0
central water tank storage,investment,3.1374,EUR/kWhCapacity,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Specific investment,2015.0
central water tank storage,lifetime,40.0,years,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Technical lifetime,2015.0
central water-sourced heat pump,FOM,0.5,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Fixed O&M",2015.0
Expand Down
2 changes: 2 additions & 0 deletions outputs/costs_2045.csv
Original file line number Diff line number Diff line change
Expand Up @@ -726,9 +726,11 @@ central solid biomass CHP powerboost CC,efficiency-heat,0.8282,per unit,"Danish
central solid biomass CHP powerboost CC,investment,3390.8967,EUR/kW_e,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","09a Wood Chips, Large 50 degree: Nominal investment ",2015.0
central solid biomass CHP powerboost CC,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","09a Wood Chips, Large 50 degree: Technical lifetime",2015.0
central water pit storage,FOM,0.6171,%/year,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Fixed O&M,2015.0
central water pit storage,energy to power ratio,150.0,h,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Ratio between energy storage and input capacity,2015.0
central water pit storage,investment,0.5144,EUR/kWhCapacity,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Specific investment,2015.0
central water pit storage,lifetime,25.0,years,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Technical lifetime,2015.0
central water tank storage,FOM,0.2901,%/year,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Fixed O&M,2015.0
central water tank storage,energy to power ratio,60.3448,h,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Ratio between energy storage and input capacity,2015.0
central water tank storage,investment,3.1374,EUR/kWhCapacity,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Specific investment,2015.0
central water tank storage,lifetime,40.0,years,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Technical lifetime,2015.0
central water-sourced heat pump,FOM,0.5,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Fixed O&M",2015.0
Expand Down
2 changes: 2 additions & 0 deletions outputs/costs_2050.csv
Original file line number Diff line number Diff line change
Expand Up @@ -726,9 +726,11 @@ central solid biomass CHP powerboost CC,efficiency-heat,0.8294,per unit,"Danish
central solid biomass CHP powerboost CC,investment,3339.6951,EUR/kW_e,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","09a Wood Chips, Large 50 degree: Nominal investment ",2015.0
central solid biomass CHP powerboost CC,lifetime,25.0,years,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","09a Wood Chips, Large 50 degree: Technical lifetime",2015.0
central water pit storage,FOM,0.6429,%/year,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Fixed O&M,2015.0
central water pit storage,energy to power ratio,150.0,h,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Ratio between energy storage and input capacity,2015.0
central water pit storage,investment,0.4938,EUR/kWhCapacity,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Specific investment,2015.0
central water pit storage,lifetime,25.0,years,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",140 PTES seasonal: Technical lifetime,2015.0
central water tank storage,FOM,0.2901,%/year,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Fixed O&M,2015.0
central water tank storage,energy to power ratio,60.3448,h,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Ratio between energy storage and input capacity,2015.0
central water tank storage,investment,3.1374,EUR/kWhCapacity,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Specific investment,2015.0
central water tank storage,lifetime,40.0,years,"Danish Energy Agency, technology_data_catalogue_for_energy_storage.xlsx",141 Large hot water tank: Technical lifetime,2015.0
central water-sourced heat pump,FOM,0.5,%/year,"Danish Energy Agency, technology_data_for_el_and_dh.xlsx","40 Comp. hp, seawater 20 MW: Fixed O&M",2015.0
Expand Down
32 changes: 29 additions & 3 deletions scripts/compile_cost_assumptions.py
Original file line number Diff line number Diff line change
Expand Up @@ -629,7 +629,9 @@ def get_data_DEA(tech, data_in, expectation=None):
'Hydrogen Consumption',
' - of which is equipment excluding heat pump',
' - of which is heat pump including its installation',
]
'Input capacity',
'Output capacity',
'Energy storage capacity']

df = pd.DataFrame()
for para in parameters:
Expand Down Expand Up @@ -724,10 +726,10 @@ def get_data_DEA(tech, data_in, expectation=None):

if "biochar pyrolysis" in tech:
df = biochar_pyrolysis_harmonise_dea(df)

elif tech == "central geothermal-sourced heat pump":
df.loc["Nominal investment (MEUR per MW)"] = df.loc[" - of which is heat pump including its installation"]

elif tech == "central geothermal heat source":
df.loc["Nominal investment (MEUR per MW)"] = df.loc[" - of which is equipment excluding heat pump"]

Expand Down Expand Up @@ -1542,6 +1544,30 @@ def order_data(tech_data):
level=0, inplace=True)
data = pd.concat([data, charger_pit], sort=True)

# add energy to power ratio for water pit storage
power_ratio_pit = tech_data.loc[("central water pit storage", "Input capacity for one unit")].copy().squeeze()
storage_capacity_pit = tech_data.loc[("central water pit storage", "Energy storage capacity for one unit")].copy().squeeze()

power_ratio_pit[years] = storage_capacity_pit[years].div(power_ratio_pit[years])
power_ratio_pit["further description"] = "Ratio between energy storage and input capacity"
power_ratio_pit["unit"] = "h"
power_ratio_pit = power_ratio_pit.to_frame().T
power_ratio_pit.rename(index={"Input capacity for one unit": "energy to power ratio"},
level=1, inplace=True)
data = pd.concat([data, power_ratio_pit], sort=True)

# add energy to power ratio for water tank storage
power_ratio_tank = tech_data.loc[("central water tank storage", "Input capacity for one unit")].copy().squeeze()
storage_capacity_tank = tech_data.loc[("central water tank storage", "Energy storage capacity for one unit")].copy().squeeze()

power_ratio_tank[years] = storage_capacity_tank[years].div(power_ratio_tank[years])
power_ratio_tank["further description"] = "Ratio between energy storage and input capacity"
power_ratio_tank["unit"] = "h"
power_ratio_tank = power_ratio_tank.to_frame().T
power_ratio_tank.rename(index={"Input capacity for one unit": "energy to power ratio"},
level=1, inplace=True)
data = pd.concat([data, power_ratio_tank], sort=True)