Clean up HVAC constants
Browse files Browse the repository at this point in the history
  • Loading branch information
puddly committed Oct 10, 2024
1 parent 3dc9300 commit 3a95adf
Showing 1 changed file with 23 additions and 21 deletions.
44 changes: 23 additions & 21 deletions zha/application/platforms/climate/const.py
Original file line number Diff line number Diff line change
Expand Up @@ -3,7 +3,7 @@
from enum import IntFlag, StrEnum
from typing import Final

from zigpy.zcl.clusters.hvac import SystemMode
from zigpy.zcl.clusters.hvac import ControlSequenceOfOperation, RunningMode, SystemMode

ATTR_SYS_MODE: Final[str] = "system_mode"
ATTR_FAN_MODE: Final[str] = "fan_mode"
Expand All @@ -20,19 +20,9 @@
ATTR_HVAC_MODE: Final[str] = "hvac_mode"
ATTR_TARGET_TEMP_HIGH: Final[str] = "target_temp_high"
ATTR_TARGET_TEMP_LOW: Final[str] = "target_temp_low"

SUPPORT_TARGET_TEMPERATURE: Final[int] = 1
SUPPORT_TARGET_TEMPERATURE_RANGE: Final[int] = 2
SUPPORT_TARGET_HUMIDITY: Final[int] = 4
SUPPORT_FAN_MODE: Final[int] = 8
SUPPORT_PRESET_MODE: Final[int] = 16
SUPPORT_SWING_MODE: Final[int] = 32
SUPPORT_AUX_HEAT: Final[int] = 64
ATTR_TEMPERATURE: Final[str] = "temperature"

PRECISION_TENTHS: Final[float] = 0.1
# Temperature attribute
ATTR_TEMPERATURE: Final[str] = "temperature"
TEMP_CELSIUS: Final[str] = "°C"

# Possible fan state
FAN_ON = "on"
Expand Down Expand Up @@ -150,17 +140,29 @@ class HVACAction(StrEnum):
PREHEATING = "preheating"


RUNNING_MODE = {0x00: HVACMode.OFF, 0x03: HVACMode.COOL, 0x04: HVACMode.HEAT}
RUNNING_MODE = {
RunningMode.Off: HVACMode.OFF,
RunningMode.Cool: HVACMode.COOL,
RunningMode.Heat: HVACMode.HEAT,
}

SEQ_OF_OPERATION = {
0x00: [HVACMode.OFF, HVACMode.COOL], # cooling only
0x01: [HVACMode.OFF, HVACMode.COOL], # cooling with reheat
0x02: [HVACMode.OFF, HVACMode.HEAT], # heating only
0x03: [HVACMode.OFF, HVACMode.HEAT], # heating with reheat
# cooling and heating 4-pipes
0x04: [HVACMode.OFF, HVACMode.HEAT_COOL, HVACMode.COOL, HVACMode.HEAT],
# cooling and heating 4-pipes
0x05: [HVACMode.OFF, HVACMode.HEAT_COOL, HVACMode.COOL, HVACMode.HEAT],
ControlSequenceOfOperation.Cooling_Only: [HVACMode.OFF, HVACMode.COOL],
ControlSequenceOfOperation.Cooling_With_Reheat: [HVACMode.OFF, HVACMode.COOL],
ControlSequenceOfOperation.Heating_Only: [HVACMode.OFF, HVACMode.HEAT],
ControlSequenceOfOperation.Heating_With_Reheat: [HVACMode.OFF, HVACMode.HEAT],
ControlSequenceOfOperation.Cooling_and_Heating: [
HVACMode.OFF,
HVACMode.HEAT_COOL,
HVACMode.COOL,
HVACMode.HEAT,
],
ControlSequenceOfOperation.Cooling_and_Heating_with_Reheat: [
HVACMode.OFF,
HVACMode.HEAT_COOL,
HVACMode.COOL,
HVACMode.HEAT,
],
0x06: [HVACMode.COOL, HVACMode.HEAT, HVACMode.OFF], # centralite specific
0x07: [HVACMode.HEAT_COOL, HVACMode.OFF], # centralite specific
}
Expand Down