3 changes: 2 additions & 1 deletion docs/content/hardware.md
Original file line number Diff line number Diff line change
@@ -1,3 +1,4 @@
(hardware/general)=
# Description and general rules of use

:::{Attention}
Expand Down Expand Up @@ -80,7 +81,7 @@ The ultrasound probe connectors are situated at the top of the device.
2D probes (linear/phase/convex) connectors are marked as ***PROBE A***
and ***PROBE B*** on the figure below.

Please refer to section ***3.1 Probe Adapters*** for other probe
Please refer to section {numref}`Section %s <set-up/probe-adapters>` for other probe
adapters options.

```{figure} img/us4r+pc+probe.jpeg
Expand Down
1 change: 1 addition & 0 deletions docs/content/manufacturer_guidelines.md
Original file line number Diff line number Diff line change
@@ -1,3 +1,4 @@
(manufacturer-guidelines)=
# Manufacturer guidelines and conditions of use

## Conditions of storage and transport
Expand Down
10 changes: 6 additions & 4 deletions docs/content/set-up.md
Original file line number Diff line number Diff line change
Expand Up @@ -3,7 +3,7 @@
The device is delivered to the user pre-assembled and boxed.

The user must connect the components and perform a setup before the
first use (see: **5 System setup**)*.* The unboxing of the device should
first use (see: {numref}`Section %s <set-up/system-setup>`). The unboxing of the device should
be performed with utmost care.

:::{Caution}
Expand Down Expand Up @@ -41,6 +41,7 @@ this manual.
The power cables should be plugged into the 120-230VAC/50Hz/60Hz mains power supply with a protective bonding.
:::

(set-up/probe-adapters)=
## Probe Adapters

Several adapters are available for use with the **us4R™** system. Please
Expand Down Expand Up @@ -102,13 +103,14 @@ restored.
To shut down the us4R™ in case of malfunction, remove the mains power cable from the electrical socket. The electrical sockets should be situated in proximity to the device and be easily accessible.
:::

(set-up/system-setup)=
# System setup

The **us4R™** should be positioned so that operation is safe --- i.e. on
a stable, flat surface in a place with no risk of spillage on the device
and away from the sources of interference and radiation. The external
power supply and power strip should be placed nearby. For more details
see section: **6 Description and general rules of use.**
see section: {numref}`Section %s <hardware/general>`.

The heat is dissipating by the us4R-3D system during normal work
conditions and may slightly increase the temperature of the device
Expand All @@ -120,9 +122,9 @@ manner that may lead to tripping, mechanical damage, wrenching the
cables out of the socket and/or damaging them through breaking or
cutting. The audio frequency noise is coming from the fans and sometimes
from the HV power supply during transmit during normal work conditions.
Please consult the Manufacturer guidelines in section **7 Manufacturer
guidelines and conditions of use.**
Please consult the Manufacturer guidelines in section ``

(power-switch)=
## Power switch, cables and ON/OFF button

The power cables connection is shown in the picture below.