added switches of configuration block
Browse files Browse the repository at this point in the history
  • Loading branch information
toggm committed Nov 15, 2024
1 parent 2664d1b commit b95c08e
Show file tree
Hide file tree
Showing 5 changed files with 388 additions and 187 deletions.
190 changes: 7 additions & 183 deletions custom_components/askoheat/api.py
Original file line number Diff line number Diff line change
Expand Up @@ -249,189 +249,8 @@ def __map_config_data(self, data: ModbusPDU) -> AskoheatDataBlock:
"""Map modbus result of config data block."""
return AskoheatDataBlock(
number_inputs={},
switches={
# TODO: Move/merge to api_conf_desc.py
# input settings register
# low byte
SwitchAttrKey.CON_MISSING_CURRENT_FLOW_TRIGGERS_ERROR: _read_flag(
data.registers[2], 0
),
SwitchAttrKey.CON_HEATER_LOAD_VALUE_ONLY_IF_CURRENT_FLOWS: _read_flag(
data.registers[2], 1
),
SwitchAttrKey.CON_LOAD_FEEDIN_VALUE_ENABLED: _read_flag(
data.registers[2], 2
),
SwitchAttrKey.CON_LOAD_SETPOINT_VALUE_ENABLED: _read_flag(
data.registers[2], 3
),
SwitchAttrKey.CON_SET_HEATER_STEP_VALUE_ENABLED: _read_flag(
data.registers[2], 4
),
SwitchAttrKey.CON_SET_ANALOG_INPUT_ENABLED: _read_flag(
data.registers[2], 5
),
SwitchAttrKey.CON_HEATPUMP_REQUEST_INPUT_ENABLED: _read_flag(
data.registers[2], 6
),
SwitchAttrKey.CON_EMERGENCY_MODE_ENABLED: _read_flag(
data.registers[2], 7
),
# high byte
SwitchAttrKey.CON_HOLD_MINIMAL_TEMPERATURE_ENABELD: _read_flag(
data.registers[2], 8
),
SwitchAttrKey.CON_HOLD_MINIMAL_TEMPERATURE_ENABELD: _read_flag(
data.registers[2], 9
),
SwitchAttrKey.CON_SOFTWARE_CONTROL_SMA_SEMP_ENABLED: _read_flag(
data.registers[2], 10
),
SwitchAttrKey.CON_SOFTWARE_CONTROL_SENEC_HOME_ENABLED: _read_flag(
data.registers[2], 11
),
# auto heater off settings register
# low byte
SwitchAttrKey.CON_AUTO_OFF_ENABLED: _read_flag(data.registers[4], 0),
SwitchAttrKey.CON_RESTART_IF_ENERGYMANAGER_CONNECTION_LOST: _read_flag(
data.registers[4], 1
),
SwitchAttrKey.CON_AUTO_OFF_MODBUS_ENABLED: _read_flag(
data.registers[4], 4
),
SwitchAttrKey.CON_AUTO_OFF_ANALOG_INPUT_ENABLED: _read_flag(
data.registers[4], 5
),
SwitchAttrKey.CON_AUTO_OFF_HEAT_PUMP_REQUEST_ENABLED: _read_flag(
data.registers[4], 6
),
SwitchAttrKey.CON_AUTO_OFF_EMERGENCY_MODE_ENABLED: _read_flag(
data.registers[4], 7
),
# heatbuffer type register
SwitchAttrKey.CON_HEATBUFFER_TYPE_TAP_WATER: _read_flag(
data.registers[6], 0
),
SwitchAttrKey.CON_HEATBUFFER_TYPE_HEATING_WATER: _read_flag(
data.registers[6], 1
),
SwitchAttrKey.CON_HEATBUFFER_TYPE_COMBINED_HEAT_AND_POWER_UNIT: _read_flag(
data.registers[6], 2
),
SwitchAttrKey.CON_HEATBUFFER_TYPE_PELLET_FIRING: _read_flag(
data.registers[6], 3
),
SwitchAttrKey.CON_HEATBUFFER_TYPE_GAS_BURNER: _read_flag(
data.registers[6], 4
),
SwitchAttrKey.CON_HEATBUFFER_TYPE_OIL_BURNER: _read_flag(
data.registers[6], 5
),
SwitchAttrKey.CON_HEATBUFFER_TYPE_HEAT_PUMP: _read_flag(
data.registers[6], 6
),
SwitchAttrKey.CON_HEATBUFFER_TYPE_OTHER: _read_flag(
data.registers[6], 7
),
# heater position register
SwitchAttrKey.CON_HEATER_POSITION_BOTTOM: _read_flag(
data.registers[8], 0
),
SwitchAttrKey.CON_HEATER_POSITION_MIDDLE: _read_flag(
data.registers[8], 1
),
SwitchAttrKey.CON_HEATER_POSITION_ASKOWALL: _read_flag(
data.registers[8], 7
),
# legio settings register
# low byte
SwitchAttrKey.CON_LEGIO_SETTINGS_USE_INTERNAL_TEMP_SENSOR: _read_flag(
data.registers[9], 0
),
SwitchAttrKey.CON_LEGIO_SETTINGS_USE_EXTERNAL_TEMP_SENSOR1: _read_flag(
data.registers[9], 1
),
SwitchAttrKey.CON_LEGIO_SETTINGS_USE_EXTERNAL_TEMP_SENSOR2: _read_flag(
data.registers[9], 2
),
SwitchAttrKey.CON_LEGIO_SETTINGS_USE_EXTERNAL_TEMP_SENSOR3: _read_flag(
data.registers[9], 3
),
SwitchAttrKey.CON_LEGIO_SETTINGS_USE_EXTERNAL_TEMP_SENSOR4: _read_flag(
data.registers[9], 4
),
# high byte
SwitchAttrKey.CON_LEGIO_SETTINGS_INTERVAL_DAILY: _read_flag(
data.registers[9], 8
),
SwitchAttrKey.CON_LEGIO_SETTINGS_INTERVAL_WEEKLY: _read_flag(
data.registers[9], 9
),
SwitchAttrKey.CON_LEGIO_SETTINGS_INTERVAL_FORTNIGHTLY: _read_flag(
data.registers[9], 10
),
SwitchAttrKey.CON_LEGIO_SETTINGS_INTERVAL_MONTHLY: _read_flag(
data.registers[9], 11
),
SwitchAttrKey.CON_LEGIO_SETTINGS_PREFER_FEEDIN_ENERGY: _read_flag(
data.registers[9], 12
),
SwitchAttrKey.CON_LEGIO_SETTINGS_PROTECTION_ENABLED: _read_flag(
data.registers[9], 13
),
# house type settings register
# low byte
SwitchAttrKey.CON_HOUSE_TYPE_SINGLE_FAMILY_HOUSE: _read_flag(
data.registers[20], 0
),
SwitchAttrKey.CON_HOUSE_TYPE_TWO_FAMILY_HOUSE: _read_flag(
data.registers[20], 1
),
SwitchAttrKey.CON_HOUSE_TYPE_APPARTMENT_BUILDING: _read_flag(
data.registers[20], 2
),
SwitchAttrKey.CON_HOUSE_TYPE_COMMERCIAL_BUILDING: _read_flag(
data.registers[20], 7
),
# Summer time int 1/0 as bool
SwitchAttrKey.CON_SUMMERTIME_ENABLED: _read_int16(data.registers[42])
== 1,
# rtu settings register
# low byte
SwitchAttrKey.CON_RTU_SEND_TWO_STOP_BITS: _read_flag(
data.registers[49], 0
),
SwitchAttrKey.CON_RTU_SEND_PARITY_EVEN: _read_flag(
data.registers[49], 1
),
SwitchAttrKey.CON_RTU_SEND_PARITY_ODD: _read_flag(
data.registers[49], 2
),
SwitchAttrKey.CON_RTU_SLAVE_MODE_ACTIVE: _read_flag(
data.registers[49], 7
),
# high byte
SwitchAttrKey.CON_RTU_MASTER_MODE_ACTIVE: _read_flag(
data.registers[49], 15
),
# temperature settings register
# low byte
SwitchAttrKey.CON_USE_INTERNAL_TEMP_SENSOR: _read_flag(
data.registers[94], 0
),
SwitchAttrKey.CON_USE_EXTERNAL_TEMP_SENSOR1: _read_flag(
data.registers[94], 1
),
SwitchAttrKey.CON_USE_EXTERNAL_TEMP_SENSOR2: _read_flag(
data.registers[94], 2
),
SwitchAttrKey.CON_USE_EXTERNAL_TEMP_SENSOR3: _read_flag(
data.registers[94], 3
),
SwitchAttrKey.CON_USE_EXTERNAL_TEMP_SENSOR4: _read_flag(
data.registers[94], 4
),
},
switches={},
# TODO: Move/merge to api_conf_desc.py
time_inputs={
TimeAttrKey.CON_LEGIO_PROTECTION_PREFERRED_START_TIME: _read_time(
register_value_hours=data.registers[12],
Expand All @@ -446,9 +265,11 @@ def __map_config_data(self, data: ModbusPDU) -> AskoheatDataBlock:
minute=_read_byte(data.registers[55]),
),
},
# TODO: Move/merge to api_conf_desc.py
text_inputs={
TextAttrKey.CON_INFO_STRING: _read_str(data.registers[22:38]),
},
# TODO: Move/merge to api_conf_desc.py
select_inputs={
SelectAttrKey.CON_RTU_BAUDRATE: _read_enum(
data.registers[46:49], Baurate
Expand Down Expand Up @@ -522,6 +343,9 @@ def _read_register_boolean_input(
if isinstance(result, bool):
return result

if isinstance(result, number):
return result == 1

LOGGER.error(
"Cannot read bool input from descriptor %r, unsupported value %r",
desc,
Expand Down