40 changes: 21 additions & 19 deletions docs/Smart-Meter-Interface.md
Original file line number Diff line number Diff line change
Expand Up @@ -950,10 +950,12 @@ Also, the source code has to be patched from 8N1 to 7E1 mode for the hardware se
The eBZ DD3 by eBZ GmbH is a three-phase model energy meter, which is sold in a number of different configurations. The D0 port is read-only with a fixed time interval of one second.

There are two communication interfaces:

* The INFO interface on the front, with a metal backplate. Pushes a reduced OBIS ASCI/SML binary datagram every second.
* The MSB interface on the top, no metal backplate. Pushes a full OBIS ASCI/SML binary datagram every second.

There are two types available using different communication settings:

* OD-type: 7 data bits, even parity, one stop bit, 9600 baud (9600 7E1) - OBIS ASCI protocol
* SM-type: 8 data bits, no parity, one stop bit, 9600 baud (9600 8N1) - SML binary protcol

Expand All @@ -966,7 +968,7 @@ Change the serial mode in the console by typing `SerialConfig 7E1`.
Example reading of the two-direction model using GPIO 3:

* "TelePeriod 30" sets telemetry period to 30 seconds (remove if not needed/wanted)
* Values for ?6.7.0 (power) are transmit immediately (precision + 16)
* Values for ?6.7.0 (power) are transmitted immediately (precision + 16)
* power readings will be negative in case of inverse power flow

??? summary "View script"
Expand Down Expand Up @@ -1056,6 +1058,24 @@ Example reading of the two-direction model using GPIO 3:
#
```

### eBZ MD3 (SML)

??? summary "View script"
```
>D
>B
=>sensor53 r
>M 1
+1,3,s,0,9600,Smartmeter
1,77070100010800ff@100000000,Total consumption,kWh,Total_in,3
1,77070100020800ff@100000000,Total generation,kWh,Total_out,3
1,77070100100700ff@1,Power L1+L2+L3,W,P_L1_L2_L3,18
1,77070100240700ff@1,Power L1,W,P_L1,18
1,77070100380700ff@1,Power L2,W,P_L2,18
1,770701004C0700ff@1,Power L3,W,P_L3,18
#
```

### EasyMeter Q1A (SML)

The Q1A series of EasyMeter is available as one- or two-way meter, with and without backstop respectively. It is also available as single or dual tariff meter. The script below works for the Q1Ax1054 variant. This variant is a single-tariff one-way meter with a backstop mechanism. The script only reads two values: the energy counter value and the current power value.
Expand Down Expand Up @@ -1590,24 +1610,6 @@ by the supplier. Therefore it is set to a fixed baud rate of 300 and can not be
#
```

### eBZ MD3 (SML)

??? summary "View script"
```
>D
>B
=>sensor53 r
>M 1
+1,3,s,0,9600,Smartmeter
1,77070100010800ff@100000000,Total consumption,kWh,Total_in,3
1,77070100020800ff@100000000,Total generation,kWh,Total_out,3
1,77070100100700ff@1,Power L1+L2+L3,W,P_L1_L2_L3,18
1,77070100240700ff@1,Power L1,W,P_L1,18
1,77070100380700ff@1,Power L2,W,P_L2,18
1,770701004C0700ff@1,Power L3,W,P_L3,18
#
```

### Fronius Symo 10.0-3-M (MODBus TCP)

Fronius inverter, using Modbus TCP feature.