The TI WL1837 Wi-Fi & Bluetooth module does not require the mac address bytes to be reversed when setting them, and the OpCode Command Field for setting the mac address is 0x006, not 0x001 (reference here). While making options for adding the ability to change the OpCode Group Field and control whether to restart the bluetooth daemon.
Running the HCI.py script as before with
sudo python3 HCI.py --key <ADVERTISMENT_KEY>
behaves the same as it does in main when the new options are not specified. I've updated the README.md to reflect these changes.Successful location of my device with your app: