iCubGenova11 S/N:050 – Right ring finger doesn't close well #1916

Open
martinaxgloria opened this issue Sep 26, 2024 · 6 comments
Open
Assignees
Labels
iCubGenova11 S/N:050 iCub2.7 S/N:050

Comments

@martinaxgloria
Copy link

martinaxgloria commented Sep 26, 2024

Robot Name πŸ€–

iCubGenova11 S/N:050

Request/Failure description

During some grasping tests, I found out that the ring finger of the right hand doesn't close as expected.

Edit: we also noticed that the thumb oppose moves in a strange way when calibrating, causing the calibration to fail for most of the joints of the right hand

Detailed context

The ring finger closes before the pinky, so the grasp is not performed optimally.

Additional context

No response

How does it affect you?

We are not able to perform the Stanford demo as well.

cc @Nicogene

@github-actions github-actions bot changed the title Right ring finger doesn't close well iCubGenova11 S/N:050 – Right ring finger doesn't close well Sep 26, 2024
@github-actions github-actions bot added the iCubGenova11 S/N:050 iCub2.7 S/N:050 label Sep 26, 2024
Copy link

⚠️ Detected missing mandatory information

Hi @martinaxgloria πŸ‘‹πŸ»

Some of the following points need your attention.

You are required to:

  • enter the Robot Name.
  • give the issue a meaningful Title.
  • provide a Detailed Context (at least 100 characters).

Please, mark the points above as solved once done.

@fbiggi
Copy link

fbiggi commented Oct 1, 2024

  • Tendini ripristinati : allego ticket di magazzino
    Sostituzione dei tendini distali su gruppo RC_TLR_010_G_011 utilizzando filo COD 2391 5MTR (rifatto 5 volte)
    Allego pagina manuale dediacata alla riparazione

Image

  • Fingertip ripristinati e risaldati da @Gandoo

image

image

@Fabrizio69 @AntonioConsilvio

@maggia80
Copy link
Contributor

maggia80 commented Oct 1, 2024

@Gandoo puoi verificare il motore prossimale del pollice destro? Guarderei se il connettore Γ¨ rovinato e proverei a farlo muovere con la jogger.

@martinaxgloria
Copy link
Author

Until this morning, the issue about the ring/pinky seemed to be solved, but after a few calibrations of the hand, the problem of the tendon appeared again.

cc @maggia80 @Nicogene @pattacini @Fabrizio69

@Gandoo
Copy link

Gandoo commented Oct 2, 2024

ho risaldato i fili sui 2 Fingertip che si erano staccati durante la sostituzione dei tendini.

Image

cc @fbiggi @martinaxgloria @Fabrizio69

@Gandoo
Copy link

Gandoo commented Oct 2, 2024

C'era un problema con l'abduzione del pollice Destro, si accostava tutto al palmo e non permetteva la riuscita della calibrazione.
Ho verificato il cablaggio e movimento con la Jogger e alla fine mi si Γ¨ staccato il filo bianco del sensore di Hall sul connettore Molex della scheda. Ricrimpato i fili, sostituito il Molex e riprovato a fare i movimento con jogger e funziona perfettamente.
In seguito @martinaxgloria ha verificato con @AntonioConsilvio i valori e in seguito la calibrazione ha cominciato ad andare a buon fine.