Skip to content

Commit

Permalink
Option to disable vertical height check
Browse files Browse the repository at this point in the history
This is useful if an internal wall component is used but connected to the same zone at two sides.
  • Loading branch information
kldjonge committed Feb 4, 2025
1 parent ed9af59 commit a81364c
Showing 1 changed file with 11 additions and 3 deletions.
14 changes: 11 additions & 3 deletions IDEAS/Buildings/Components/InternalWall.mo
Original file line number Diff line number Diff line change
Expand Up @@ -67,6 +67,8 @@ model InternalWall "interior opaque wall between two zones"
parameter Boolean use_y_doo = false
"=true, to enable controllable cavity (door) input"
annotation(Dialog(enable=hasCavity,group="Cavity or open door",tab="Advanced"));
parameter Boolean CheckVH=true "Enable to not check vertical heights, if an internal floor or element is connected to the same zone at both sides this should be set to false" annotation(Dialog(group="Vertical height check",tab="Airflow"));

IDEAS.Buildings.Components.Interfaces.ZoneBus propsBus_b(
redeclare final package Medium = Medium,
numIncAndAziInBus=sim.numIncAndAziInBus,
Expand Down Expand Up @@ -155,17 +157,19 @@ initial equation
assert(IDEAS.Utilities.Math.Functions.isAngle(incInt, IDEAS.Types.Tilt.Wall), "In " + getInstanceName() + ": Cavities without airflow are only supported for vertical walls, but inc=" + String(incInt) + ". The model is not accurate.", level = AssertionLevel.warning);
end if;

if sim.interZonalAirFlowType <> IDEAS.BoundaryConditions.Types.InterZonalAirFlow.None and IDEAS.Utilities.Math.Functions.isAngle(inc,0) then
if CheckVH and sim.interZonalAirFlowType <> IDEAS.BoundaryConditions.Types.InterZonalAirFlow.None and IDEAS.Utilities.Math.Functions.isAngle(inc,0) then
assert(hAbs_floor_a<hAbs_floor_b, getInstanceName()+ " is a ceiling, but the floor of the zone at probsbus_b (hfloor="+String(hAbs_floor_b) +") does not lie below the floor of zone at probsbus_a (hfloor="+String(hAbs_floor_a) +"), this should be fixed",level=AssertionLevel.error);
elseif sim.interZonalAirFlowType <> IDEAS.BoundaryConditions.Types.InterZonalAirFlow.None and IDEAS.Utilities.Math.Functions.isAngle(inc,Modelica.Constants.pi) then
elseif CheckVH and sim.interZonalAirFlowType <> IDEAS.BoundaryConditions.Types.InterZonalAirFlow.None and IDEAS.Utilities.Math.Functions.isAngle(inc,Modelica.Constants.pi) then
assert(hAbs_floor_a>hAbs_floor_b, getInstanceName()+ " is a floor, but the floor of the zone at probsbus_a (hfloor="+String(hAbs_floor_a) +") does not lie below the floor of zone at probsbus_b (hfloor="+String(hAbs_floor_b) +"), this should be fixed",level=AssertionLevel.error);
end if;

if sim.interZonalAirFlowType == IDEAS.BoundaryConditions.Types.InterZonalAirFlow.TwoPorts then
if CheckVH and sim.interZonalAirFlowType == IDEAS.BoundaryConditions.Types.InterZonalAirFlow.TwoPorts then
assert(hAbs_floor_a+hRelSurfBot_a==hAbs_floor_b+hRelSurfBot_b,"The absolute height of internal wall "+ getInstanceName() +" does not match between both sides of the wall, check the input for hfloor and hzone of the corresponding zones. At propsbus_a the absolute surface starting height is "+String(hAbs_floor_a+hRelSurfBot_a)+"m while at propsbus_b the absolute surface starting height is "+String(hAbs_floor_b+hRelSurfBot_b)+"m",level=AssertionLevel.error);
assert(hAbs_floor_a+hRelSurfBot_a+hRelOpeBot_a==hAbs_floor_b+hRelSurfBot_b+hRelOpeBot_b,"The absolute height of the large cavity in internal wall "+ getInstanceName() +" does not match between both sides of the wall, check the input for hfloor and hzone of the corresponding zones. At propsbus_a the opening its absolute starting height is "+String(hAbs_floor_a+hRelSurfBot_a+hRelOpeBot_a)+"m while at propsbus_b the opening its absolute starting height is "+String(hAbs_floor_b+hRelSurfBot_b+hRelOpeBot_b)+"m",level=AssertionLevel.error);
end if;

assert(CheckVH and sim.interZonalAirFlowType == IDEAS.BoundaryConditions.Types.InterZonalAirFlow.TwoPorts,"Vertical height check was disabled for "+getInstanceName()+" but InterZonalAirFlow.TwoPorts is active",AssertionLevel.warning);
equation
connect(constOne.y, crackOrOperableDoor.y);
connect(layMul.port_b, propsBus_b.surfRad) annotation(
Expand Down Expand Up @@ -272,6 +276,10 @@ We assume that the value of <code>A</code> excludes the surface area of the cavi
</html>", revisions = "<html>
<ul>
<li>
February 4, 2025, by Klaas De Jonge:<br/>
Boolean to disable vertical height check was added
</li>
<li>
January 24, 2025, by Klaas De Jonge:<br/>
Add dummy connections for <code>hzone</code> and <code>hfloor</code> in <code>propsbus_b</code> to avoid translation warnings.
See <a href=\"https://github.com/open-ideas/IDEAS/issues/1402\">#1402</a>
Expand Down

0 comments on commit a81364c