@@ -0,0 +1,308 @@ | ||
substitutions: | ||
device_name: p1-dongle-pro-h2o | ||
device_description: "P1 Dongle Pro + H2O counter" | ||
friendly_name: P1 Dongle Pro H2O | ||
prj_version: "2024.08.01" | ||
|
||
esphome: | ||
name: ${device_name} | ||
comment: "${device_description}" | ||
name_add_mac_suffix: false | ||
project: | ||
name: "smartstuff.p1_dongle_pro_h2o" | ||
version: ${prj_version} | ||
platformio_options: | ||
upload_speed: 1500000 | ||
|
||
esp32: | ||
board: esp32-c3-devkitm-1 | ||
|
||
improv_serial: | ||
next_url: http://{{ip_address}} | ||
|
||
api: | ||
services: | ||
- service: p1_dongle_reboot | ||
then: | ||
- button.press: | ||
id: reboot | ||
- service: set_water_total | ||
variables: | ||
set_value: int | ||
then: | ||
- globals.set: | ||
id: totalWaterUsage | ||
value: !lambda 'return set_value;' | ||
|
||
globals: | ||
- id: totalWaterUsage | ||
type: int | ||
restore_value: true # aanpassen naar no indien de nieuwe waarde onder de oude ligt | ||
initial_value: '0' | ||
|
||
ota: | ||
platform: esphome | ||
|
||
captive_portal: | ||
web_server: | ||
wifi: | ||
# Enable fallback hotspot (captive portal) in case wifi connection fails | ||
ap: | ||
ssid: ${device_name} | ||
ap_timeout: 15s | ||
|
||
dashboard_import: | ||
package_import_url: github://mhendriks/esphome-p1/p1-dongle-pro-h2o-dsmr22.yaml@main | ||
|
||
# Enable logging | ||
logger: | ||
level: ERROR | ||
|
||
dsmr: | ||
crc_check: false | ||
|
||
uart: | ||
rx_pin: | ||
number: 10 | ||
inverted: true | ||
rx_buffer_size: 1700 | ||
baud_rate: 9600 | ||
data_bits: 7 | ||
parity: EVEN | ||
stop_bits: 1 | ||
|
||
light: | ||
- platform: status_led | ||
name: "status led" | ||
output: status_output | ||
internal: true | ||
- platform: neopixelbus | ||
variant: WS2812 | ||
pin: 8 | ||
num_leds: 1 | ||
name: "_Status LED" | ||
id: esp32c3_rgb_led | ||
entity_category: config | ||
restore_mode: ALWAYS_OFF | ||
internal: true | ||
# method: | ||
# type: esp32_rmt | ||
# channel: 0 | ||
|
||
switch: | ||
- platform: template | ||
id: status_led_switch | ||
# name: "Status LED Switch" | ||
optimistic: true | ||
on_turn_on: | ||
- light.turn_on: | ||
id: esp32c3_rgb_led | ||
red: 0% | ||
green: 0% | ||
blue: 100% | ||
brightness: 40% | ||
transition_length: 50ms | ||
on_turn_off: | ||
- light.turn_off: | ||
id: esp32c3_rgb_led | ||
transition_length: 50ms | ||
|
||
output: | ||
- platform: template | ||
id: status_output | ||
type: binary | ||
write_action: | ||
- if: | ||
condition: | ||
lambda: return state > 0; | ||
then: | ||
- if: | ||
condition: | ||
switch.is_off: status_led_switch | ||
then: | ||
switch.turn_on: status_led_switch | ||
else: | ||
- if: | ||
condition: | ||
switch.is_on: status_led_switch | ||
then: | ||
switch.turn_off: status_led_switch | ||
|
||
button: | ||
- platform: restart | ||
name: "_Restart device" | ||
id: reboot | ||
- platform: factory_reset | ||
name: "_Restart with Factory Default Settings" | ||
|
||
binary_sensor: | ||
- platform: gpio | ||
pin: | ||
number: 9 | ||
inverted: true | ||
mode: | ||
input: true | ||
pullup: true | ||
name: _PushButton | ||
on_press: | ||
then: | ||
- switch.toggle: status_led_switch | ||
|
||
sensor: | ||
- platform: pulse_meter | ||
name: "Watermeter pulse" | ||
pin: | ||
number: 0 | ||
mode: | ||
input: true | ||
pullup: true | ||
id: h2o_pulse | ||
state_class: measurement | ||
unit_of_measurement: 'L' | ||
device_class: water | ||
internal_filter: 13us | ||
internal_filter_mode: EDGE | ||
icon: mdi:flash-outline | ||
accuracy_decimals: 0 | ||
# total: | ||
# name: "Water Total" | ||
# id: h2o_total | ||
# state_class: total_increasing | ||
# icon: mdi:water | ||
# unit_of_measurement: L | ||
# accuracy_decimals: 0 | ||
- platform: template | ||
name: "Watermeter total" | ||
state_class: "total_increasing" | ||
device_class: "water" | ||
icon: mdi:water | ||
update_interval: 1s | ||
unit_of_measurement: L | ||
accuracy_decimals: 0 | ||
lambda: |- | ||
if (id(h2o_pulse).state > 0) id(totalWaterUsage) += 1; | ||
return id(totalWaterUsage); | ||
- platform: dsmr | ||
# energy_delivered_lux: | ||
# name: "Energy Consumed Luxembourg" | ||
# state_class: total_increasing | ||
energy_delivered_tariff1: | ||
name: "Energy Consumed Tariff 1" | ||
state_class: total_increasing | ||
energy_delivered_tariff2: | ||
name: "Energy Consumed Tariff 2" | ||
state_class: total_increasing | ||
# energy_returned_lux: | ||
# name: "Energy Produced Luxembourg" | ||
# state_class: total_increasing | ||
energy_returned_tariff1: | ||
name: "Energy Produced Tariff 1" | ||
state_class: total_increasing | ||
energy_returned_tariff2: | ||
name: "Energy Produced Tariff 2" | ||
state_class: total_increasing | ||
power_delivered: | ||
name: "Power Consumed" | ||
unit_of_measurement: "W" | ||
state_class: "measurement" | ||
accuracy_decimals: 0 | ||
filters: | ||
- multiply: 1000 | ||
power_returned: | ||
name: "Power Produced" | ||
unit_of_measurement: "W" | ||
state_class: "measurement" | ||
accuracy_decimals: 0 | ||
filters: | ||
- multiply: 1000 | ||
electricity_failures: | ||
name: "Electricity Failures" | ||
icon: mdi:alert | ||
electricity_long_failures: | ||
name: "Long Electricity Failures" | ||
icon: mdi:alert | ||
voltage_l1: | ||
name: "Voltage Phase 1" | ||
voltage_l2: | ||
name: "Voltage Phase 2" | ||
voltage_l3: | ||
name: "Voltage Phase 3" | ||
current_l1: | ||
name: "Current Phase 1" | ||
current_l2: | ||
name: "Current Phase 2" | ||
current_l3: | ||
name: "Current Phase 3" | ||
power_delivered_l1: | ||
name: "Power Consumed Phase 1" | ||
unit_of_measurement: "W" | ||
state_class: "measurement" | ||
accuracy_decimals: 0 | ||
filters: | ||
- multiply: 1000 | ||
power_delivered_l2: | ||
name: "Power Consumed Phase 2" | ||
unit_of_measurement: "W" | ||
state_class: "measurement" | ||
accuracy_decimals: 0 | ||
filters: | ||
- multiply: 1000 | ||
power_delivered_l3: | ||
name: "Power Consumed Phase 3" | ||
unit_of_measurement: "W" | ||
state_class: "measurement" | ||
accuracy_decimals: 0 | ||
filters: | ||
- multiply: 1000 | ||
power_returned_l1: | ||
name: "Power Produced Phase 1" | ||
unit_of_measurement: "W" | ||
state_class: "measurement" | ||
accuracy_decimals: 0 | ||
filters: | ||
- multiply: 1000 | ||
power_returned_l2: | ||
name: "Power Produced Phase 2" | ||
unit_of_measurement: "W" | ||
state_class: "measurement" | ||
accuracy_decimals: 0 | ||
filters: | ||
- multiply: 1000 | ||
power_returned_l3: | ||
name: "Power Produced Phase 3" | ||
unit_of_measurement: "W" | ||
state_class: "measurement" | ||
accuracy_decimals: 0 | ||
filters: | ||
- multiply: 1000 | ||
gas_delivered: | ||
name: "Gas Consumed" | ||
state_class: total_increasing | ||
gas_delivered_be: | ||
name: "Gas Consumed Belgium" | ||
state_class: total_increasing | ||
- platform: uptime | ||
name: "_Uptime" | ||
- platform: wifi_signal | ||
name: "_Wi-Fi Signal" | ||
update_interval: 60s | ||
|
||
text_sensor: | ||
- platform: dsmr | ||
identification: | ||
name: "DSMR Identification" | ||
p1_version: | ||
name: "DSMR Version" | ||
p1_version_be: | ||
name: "DSMR Version Belgium" | ||
- platform: wifi_info | ||
ip_address: | ||
name: "_IP Address" | ||
ssid: | ||
name: "_Wi-Fi SSID" | ||
bssid: | ||
name: "_Wi-Fi BSSID" | ||
- platform: version | ||
name: "_ESPHome Version" | ||
hide_timestamp: true |