Skip to content

golioth/reference-design-greenhouse

Repository files navigation

Golioth Greenhouse Controller Reference Design

The Greenhouse controller demonstrates how to monitor environmental factors like light intensity, temperature, humidity, and pressure using the Golioth IoT platform. Specifically, the following parameters can be monitored:

  • 💦 Relative humidity (%RH)
  • 🌡️ Temperature (°C)
  • 💨 Pressure (kPa)
  • ☀️ Light Intensity (LUX)
  • 🔴 Red Light Value
  • 🟢 Green Light Value
  • 🔵 Blue Light Value

Relays are used to remotely actuate grow lights and ventilation automatically or on demand. From the Golioth web console you may deploy OTA firmware updates, adjust device Settings, and issue Remote Procedure Calls (RPCs).

Business use cases and hardware build details are available on the Greenhouse Controller Project Page.

This repository contains the firmware source code and pre-built release firmware images.

Supported Hardware

  • Nordic nRF9160-DK
  • Golioth Aludel Elixir
  • Golioth Aludel Mini

Additional Sensors/Components

  • Broadcom ADPS-9960 digital ambient light sensor
  • Bosch BME280 digital humidity, pressure, and temperature Sensors
  • OMRON G6D1AASIDC5s minature relay (x2)

Golioth Features

This app implements:

Settings Service

The following settings should be set in the Device Settings menu of the Golioth Console.

  • LOOP_DELAY_S Adjusts the delay between sensor readings. Set to an integer value (seconds).

    Default value is 60 seconds.

  • LIGHT_AUTO Enables or disables the automatic grow light control. Set to a boolean value.

    Default value is true.

  • TEMP_AUTO Enables or disables the automatic ventilation control. Set to a boolean value.

    Default value is true.

  • LIGHT_THRESH Clear Light Intensity threshold for automatic grow light control.

    Default value is 900 LUX.

  • TEMP_THRESH Temperature threshold for automatic ventilation control.

    Default value is 21.5 °C.

Remote Procedure Call (RPC) Service

The following RPCs can be initiated in the Remote Procedure Call menu of the Golioth Console.

  • get_network_info Query and return network information.

  • reboot Reboot the system.

  • set_log_level Set the log level.

    The method takes a single parameter which can be one of the following integer values:

    • 0: LOG_LEVEL_NONE
    • 1: LOG_LEVEL_ERR
    • 2: LOG_LEVEL_WRN
    • 3: LOG_LEVEL_INF
    • 4: LOG_LEVEL_DBG

Time-Series Stream data

Sensor data is periodically sent to the following sensor/* paths of the LightDB Stream service:

  • sensor/light/int: Clear Light Intensity (LUX)
  • sensor/light/r: Red Light Value
  • sensor/light/g: Green Light Value
  • sensor/light/b: Blue Light Value
  • sensor/weather/humidity:Humidity (%RH)
  • sensor/weather/pressure: Pressure (kPa)
  • sensor/weather/temp: Temperature (°C)
{
  "sensor": {
    "light": {
      "b": 21,
      "g": 26,
      "int": 79,
      "r": 43
    },
    "weather": {
      "hum": 51.5957,
      "pre": 97.726843,
      "tem": 26.47
    }
  }
}

If your board includes a battery, voltage and level readings will be sent to the battery path.

Note

Your Golioth project must have a Pipeline enabled to receive this data. See the Add Pipeline to Golioth section below.

Stateful Data (LightDB State)

The concept of Digital Twin is demonstrated with the LightDB State light and vent variables that are subpaths of the desired and state paths.

  • desired values may be changed from the cloud side. The device will recognize these, validate them for [0..1] bounding, and then switch the appropriate relay on or off based on this value. The device will then reset these values to -1. Note that these values will be overridden by the application if the Settings system has the auto feature enabled.
  • state values will be updated by the device to reflect the device's actual state for the two relays. The cloud may read the state paths to determine device status. In this arrangement, only the device should ever write to the state paths.
{
  "desired": {
    "light": -1,
    "vent": -1
  },
  "state": {
    "light": 0,
    "vent": 0
  }
}

But default the state values will be 0 and 1. Try updating the desired values and observe how the device updates its state.

OTA Firmware Update

This application includes the ability to perform Over-the-Air (OTA) firmware updates. To do so, you need a binary compiled with a different version number than what is currently running on the device.

Note

If a newer release is available than what your device is currently running, you may download the pre-compiled binary that ends in _update.bin and use it in step 2 below.

  1. Update the version number in the VERSION file and perform a pristine (important) build to incorporate the version change.

  2. Upload the build/app/zephyr/zephyr.signed.bin file as a Package for your Golioth project.

    • Use main as the package name.
    • Use the same version number from step 1.
  3. Create a Cohort and add your device to it.

  4. Create a Deployment for your Cohort using the package name and version number from step 2.

  5. Devices in your Cohort will automatically upgrade to the most recently deployed firmware.

Visit the Golioth Docs OTA Firmware Upgrade page for more info.

Further Information in Header Files

Please refer to the comments in each header file for a service-by-service explanation of this template.

Add Pipeline to Golioth

Golioth uses Pipelines to route stream data. This gives you flexibility to change your data routing without requiring updated device firmware.

Whenever sending stream data, you must enable a pipeline in your Golioth project to configure how that data is handled. Add the contents of pipelines/json-to-lightdb.yml as a new pipeline as follows (note that this is the default pipeline for new projects and may already be present):

  1. Navigate to your project on the Golioth web console.
  2. Select Pipelines from the left sidebar and click the Create button.
  3. Give your new pipeline a name and paste the pipeline configuration into the editor.
  4. Click the toggle in the bottom right to enable the pipeline and then click Create.

All data streamed to Golioth in JSON format will now be routed to LightDB Stream and may be viewed using the web console. You may change this behavior at any time without updating firmware simply by editing this pipeline entry.

Local set up

Important

Do not clone this repo using git. Zephyr's west meta tool should be used to set up your local workspace.

Install the Python virtual environment (recommended)

cd ~
mkdir golioth-reference-design-greenhouse
python -m venv golioth-reference-greenhouse/.venv
source golioth-reference-design-greenhouse/.venv/bin/activate
pip install wheel west ecdsa

Use west to initialize and install

cd ~/golioth-reference-design-greenhouse
west init -m [email protected]:golioth/reference-design-greenhouse.git .
west update
west zephyr-export
pip install -r deps/zephyr/scripts/requirements.txt

Building the application

Build the Zephyr sample application for the Nordic nRF9160 DK (nrf9160dk_nrf9160_ns) from the top level of your project. After a successful build you will see a new build directory. Note that any changes (and git commits) to the project itself will be inside the app folder. The build and deps directories being one level higher prevents the repo from cataloging all of the changes to the dependencies and the build (so no .gitignore is needed).

Prior to building, update VERSION file to reflect the firmware version number you want to assign to this build. Then run the following commands to build and program the firmware onto the device.

Warning

You must perform a pristine build (use -p or remove the build directory) after changing the firmware version number in the VERSION file for the change to take effect.

$ (.venv) west build -p -b nrf9160dk/nrf9160/ns --sysbuild app
$ (.venv) west flash

Configure PSK-ID and PSK using the device shell based on your Golioth credentials and reboot:

uart:~$ settings set golioth/psk-id <my-psk-id@my-project>
uart:~$ settings set golioth/psk <my-psk>
uart:~$ kernel reboot cold

External Libraries

The following code libraries are installed by default. If you are not using the custom hardware to which they apply, you can safely remove these repositories from west.yml and remove the includes/function calls from the C code.

  • golioth-zephyr-boards includes the board definitions for the Golioth Aludel-Mini
  • zephyr-network-info is a helper library for querying, formatting, and returning network connection information via Zephyr log or Golioth RPC

Have Questions?