Skip to content

Commit

Permalink
Templates update for nightly evcc-io/evcc@dd4ff04
Browse files Browse the repository at this point in the history
  • Loading branch information
naltatis committed Dec 21, 2024
1 parent 2227841 commit faab998
Show file tree
Hide file tree
Showing 22 changed files with 36 additions and 38 deletions.
2 changes: 0 additions & 2 deletions templates/nightly/de/meter/huawei-sun2000_0.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -58,7 +58,6 @@ render:
port: 502 # Port
timeout: 15s # optional
storageunit: 1 # optional
forceaccharging: false # AC-Laden bleibt aktiv zum Laden des Speichers aus anderen AC Quellen für Wechselrichterkaskaden. Verhindert Stand-by. (optional)
- usage: pv
default: |
type: template
Expand Down Expand Up @@ -109,7 +108,6 @@ render:
port: 502 # Port
timeout: 15s # optional
storageunit: 1 # optional
forceaccharging: false # AC-Laden bleibt aktiv zum Laden des Speichers aus anderen AC Quellen für Wechselrichterkaskaden. Verhindert Stand-by. (optional)
- usage: battery
default: |
type: template
Expand Down
Original file line number Diff line number Diff line change
@@ -1,15 +1,17 @@
product:
brand: Kostal
description: Plenticore Hybrid (Gen2)
description: Plenticore Hybrid, inkl. Netzladung der Hausbatterie
capabilities: ["battery-control"]
description: |
Nur ein System kann und darf auf den Wechselrichter zugreifen! Für die aktive Batteriesteuerung muss die externe Batteriesteuerung über Modbus mit dem Handwerkerzugang aktiviert sein. Das Netzladen steht mit dieser Vorlage zur Verfügung, ist aktuell jedoch inkompatibel mit Wechselrichtern der HW-Version 0100).
Nur ein System kann und darf auf den Wechselrichter zugreifen! Für die aktive Batteriesteuerung muss die Funktion externe Batteriesteuerung über Modbus mit dem Handwerkerzugang aktiviert sein. **_Ist grundsätzlich anwendbar für verschiedene Wechselrichter Generationen (G1/G2/G3)._**
**Das Netzladen der Batterie steht mit dieser Vorlage zur Verfügung, ist aktuell jedoch inkompatibel mit wenigen älteren Wechselrichtern - _sorgfältig testen_!**
_siehe auch https://github.com/evcc-io/evcc/wiki/Kostal-Plenticore_
render:
- usage: pv
default: |
type: template
template: kostal-plenticore-hw0200
template: kostal-plenticore-gen2
usage: pv
# Modbus TCP
Expand All @@ -19,7 +21,7 @@ render:
port: 1502 # Port
advanced: |
type: template
template: kostal-plenticore-hw0200
template: kostal-plenticore-gen2
usage: pv
# Modbus TCP
Expand All @@ -33,7 +35,7 @@ render:
- usage: battery
default: |
type: template
template: kostal-plenticore-hw0200
template: kostal-plenticore-gen2
usage: battery
# Modbus TCP
Expand All @@ -43,7 +45,7 @@ render:
port: 1502 # Port
advanced: |
type: template
template: kostal-plenticore-hw0200
template: kostal-plenticore-gen2
usage: battery
# Modbus TCP
Expand Down
5 changes: 2 additions & 3 deletions templates/nightly/de/meter/kostal-plenticore_0.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -3,7 +3,8 @@ product:
description: Plenticore Hybrid
capabilities: ["battery-control"]
description: |
Nur ein System kann und darf auf den Wechselrichter zugreifen! Für die aktive Batteriesteuerung muss die externe Batteriesteuerung über Modbus mit dem Handwerkerzugang aktiviert sein. Diese Vorlage ist für Wechselrichter mit der HW Version 0100. Netzladen steht nicht zur verfügung.
Nur ein System kann und darf auf den Wechselrichter zugreifen! Für die aktive Batteriesteuerung muss die Funktion externe Batteriesteuerung über Modbus mit dem Handwerkerzugang aktiviert sein.
**Das Netzladen der Batterie steht nicht zur Verfügung!** _siehe auch https://github.com/evcc-io/evcc/wiki/Kostal-Plenticore_
render:
- usage: pv
Expand All @@ -30,7 +31,6 @@ render:
endianness: little # optional
maxacpower: 0 # Maximale AC Leistung des Hybrid-Wechselrichters (optional)
minsoc: 25 # Ladung mit maximaler Geschwindigkeit bis zu dem angegeben Ladestand unabhängig PV-Erzeugung, wenn der Lademodus nicht auf 'Aus' steht (optional)
maxsoc: # optional
watchdog: 60s # optional
- usage: battery
default: |
Expand All @@ -56,5 +56,4 @@ render:
endianness: little # optional
capacity: 50 # Akkukapazität in kWh (optional)
minsoc: 25 # Ladung mit maximaler Geschwindigkeit bis zu dem angegeben Ladestand unabhängig PV-Erzeugung, wenn der Lademodus nicht auf 'Aus' steht (optional)
maxsoc: # optional
watchdog: 60s # optional
2 changes: 1 addition & 1 deletion templates/nightly/de/meter/saj-h2_0.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -148,6 +148,6 @@ render:
host: 192.0.2.2 # Hostname
port: 502 # Port
capacity: 50 # Akkukapazität in kWh (optional)
defaultmode: 2 # optional
defaultmode: 2 # Standardmodus für die aktive Batteriesteuerung auf die der Wechselrichter wieder nach einem Laden des Speichers oder Unterbinden der Entladung zurückfällt. (optional)
minsoc: 20 # Ladung mit maximaler Geschwindigkeit bis zu dem angegeben Ladestand unabhängig PV-Erzeugung, wenn der Lademodus nicht auf 'Aus' steht (optional)
maxsoc: 95 # optional
2 changes: 1 addition & 1 deletion templates/nightly/de/meter/saj-h2_1.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -148,6 +148,6 @@ render:
host: 192.0.2.2 # Hostname
port: 502 # Port
capacity: 50 # Akkukapazität in kWh (optional)
defaultmode: 2 # optional
defaultmode: 2 # Standardmodus für die aktive Batteriesteuerung auf die der Wechselrichter wieder nach einem Laden des Speichers oder Unterbinden der Entladung zurückfällt. (optional)
minsoc: 20 # Ladung mit maximaler Geschwindigkeit bis zu dem angegeben Ladestand unabhängig PV-Erzeugung, wenn der Lademodus nicht auf 'Aus' steht (optional)
maxsoc: 95 # optional
2 changes: 1 addition & 1 deletion templates/nightly/de/meter/sofarsolar-g3_0.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -147,4 +147,4 @@ render:
host: 192.0.2.2 # Hostname
port: 8899 # Port
capacity: 50 # Akkukapazität in kWh (optional)
defaultmode: 0 # optional
defaultmode: 0 # Standardmodus für die aktive Batteriesteuerung. Gültige Werte sind 0 (Eigenbedarfsmodus), 1 (Nutzungszeitmodus), 2 (Zeitmodus), 4 (Peak-shaving Modus) (optional)
2 changes: 1 addition & 1 deletion templates/nightly/de/meter/sofarsolar-g3_1.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -147,4 +147,4 @@ render:
host: 192.0.2.2 # Hostname
port: 8899 # Port
capacity: 50 # Akkukapazität in kWh (optional)
defaultmode: 0 # optional
defaultmode: 0 # Standardmodus für die aktive Batteriesteuerung. Gültige Werte sind 0 (Eigenbedarfsmodus), 1 (Nutzungszeitmodus), 2 (Zeitmodus), 4 (Peak-shaving Modus) (optional)
2 changes: 1 addition & 1 deletion templates/nightly/de/meter/sofarsolar-g3_2.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -147,4 +147,4 @@ render:
host: 192.0.2.2 # Hostname
port: 8899 # Port
capacity: 50 # Akkukapazität in kWh (optional)
defaultmode: 0 # optional
defaultmode: 0 # Standardmodus für die aktive Batteriesteuerung. Gültige Werte sind 0 (Eigenbedarfsmodus), 1 (Nutzungszeitmodus), 2 (Zeitmodus), 4 (Peak-shaving Modus) (optional)
2 changes: 1 addition & 1 deletion templates/nightly/de/meter/sofarsolar-g3_3.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -147,4 +147,4 @@ render:
host: 192.0.2.2 # Hostname
port: 8899 # Port
capacity: 50 # Akkukapazität in kWh (optional)
defaultmode: 0 # optional
defaultmode: 0 # Standardmodus für die aktive Batteriesteuerung. Gültige Werte sind 0 (Eigenbedarfsmodus), 1 (Nutzungszeitmodus), 2 (Zeitmodus), 4 (Peak-shaving Modus) (optional)
2 changes: 1 addition & 1 deletion templates/nightly/de/meter/solax_0.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -146,4 +146,4 @@ render:
host: 192.0.2.2 # Hostname
port: 502 # Port
capacity: 50 # Akkukapazität in kWh (optional)
defaultmode: 0 # optional
defaultmode: 0 # Standardmodus für die aktive Batteriesteuerung auf die der Wechselrichter wieder nach einem Laden des Speichers oder Unterbinden der Entladung zurückfällt. (optional)
2 changes: 1 addition & 1 deletion templates/nightly/de/meter/solax_1.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -146,4 +146,4 @@ render:
host: 192.0.2.2 # Hostname
port: 502 # Port
capacity: 50 # Akkukapazität in kWh (optional)
defaultmode: 0 # optional
defaultmode: 0 # Standardmodus für die aktive Batteriesteuerung auf die der Wechselrichter wieder nach einem Laden des Speichers oder Unterbinden der Entladung zurückfällt. (optional)
2 changes: 0 additions & 2 deletions templates/nightly/en/meter/huawei-sun2000_0.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -58,7 +58,6 @@ render:
port: 502 # Port
timeout: 15s # optional
storageunit: 1 # optional
forceaccharging: false # Keep AC charging active to charge the storage from other inverters via AC. Prevents stand-by. (optional)
- usage: pv
default: |
type: template
Expand Down Expand Up @@ -109,7 +108,6 @@ render:
port: 502 # Port
timeout: 15s # optional
storageunit: 1 # optional
forceaccharging: false # Keep AC charging active to charge the storage from other inverters via AC. Prevents stand-by. (optional)
- usage: battery
default: |
type: template
Expand Down
Original file line number Diff line number Diff line change
@@ -1,15 +1,17 @@
product:
brand: Kostal
description: Plenticore Hybrid (Gen2)
description: Plenticore Hybrid, incl. grid charging of the house battery
capabilities: ["battery-control"]
description: |
Only a single system may access the inverter! For active battery control, the external battery control via Modbus must be activated using installer access. The function for grid charging the battery is available using this template, but is currently incompatible with inverters of HW version 0100.
Only a single system may access the inverter! For active battery control, the feature external battery control via modbus must be activated using installer access. **_Can basically be used for various inverter generations (G1/G2/G3)._**
**The function for grid charging the battery is available using this template, but is currently incompatible with some older inverters - _test carefully_!**
_see also https://github.com/evcc-io/evcc/wiki/Kostal-Plenticore_
render:
- usage: pv
default: |
type: template
template: kostal-plenticore-hw0200
template: kostal-plenticore-gen2
usage: pv
# Modbus TCP
Expand All @@ -19,7 +21,7 @@ render:
port: 1502 # Port
advanced: |
type: template
template: kostal-plenticore-hw0200
template: kostal-plenticore-gen2
usage: pv
# Modbus TCP
Expand All @@ -33,7 +35,7 @@ render:
- usage: battery
default: |
type: template
template: kostal-plenticore-hw0200
template: kostal-plenticore-gen2
usage: battery
# Modbus TCP
Expand All @@ -43,7 +45,7 @@ render:
port: 1502 # Port
advanced: |
type: template
template: kostal-plenticore-hw0200
template: kostal-plenticore-gen2
usage: battery
# Modbus TCP
Expand Down
5 changes: 2 additions & 3 deletions templates/nightly/en/meter/kostal-plenticore_0.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -3,7 +3,8 @@ product:
description: Plenticore Hybrid
capabilities: ["battery-control"]
description: |
Only a single system may access the inverter! For active battery control, the external battery control via Modbus must be activated using installer access. This template is for inverters with HW version 0100. Grid charging is not available.
Only a single system may access the inverter! For active battery control the function external battery control via Modbus must be activated using installer access.
**Grid charging is not available!** _see also https://github.com/evcc-io/evcc/wiki/Kostal-Plenticore_
render:
- usage: pv
Expand All @@ -30,7 +31,6 @@ render:
endianness: little # optional
maxacpower: 0 # Maximum AC power of the hybrid inverter (optional)
minsoc: 25 # Immediate charging with maximum power up to the defined state of charge independently from solar production if the charge mode is not set to 'Off' (optional)
maxsoc: # optional
watchdog: 60s # optional
- usage: battery
default: |
Expand All @@ -56,5 +56,4 @@ render:
endianness: little # optional
capacity: 50 # Battery capacity in kWh (optional)
minsoc: 25 # Immediate charging with maximum power up to the defined state of charge independently from solar production if the charge mode is not set to 'Off' (optional)
maxsoc: # optional
watchdog: 60s # optional
2 changes: 1 addition & 1 deletion templates/nightly/en/meter/saj-h2_0.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -148,6 +148,6 @@ render:
host: 192.0.2.2 # Hostname
port: 502 # Port
capacity: 50 # Battery capacity in kWh (optional)
defaultmode: 2 # optional
defaultmode: 2 # Default mode for battery control to which the inverter falls back after charging the battery or after stopping discharge. (optional)
minsoc: 20 # Immediate charging with maximum power up to the defined state of charge independently from solar production if the charge mode is not set to 'Off' (optional)
maxsoc: 95 # optional
2 changes: 1 addition & 1 deletion templates/nightly/en/meter/saj-h2_1.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -148,6 +148,6 @@ render:
host: 192.0.2.2 # Hostname
port: 502 # Port
capacity: 50 # Battery capacity in kWh (optional)
defaultmode: 2 # optional
defaultmode: 2 # Default mode for battery control to which the inverter falls back after charging the battery or after stopping discharge. (optional)
minsoc: 20 # Immediate charging with maximum power up to the defined state of charge independently from solar production if the charge mode is not set to 'Off' (optional)
maxsoc: 95 # optional
2 changes: 1 addition & 1 deletion templates/nightly/en/meter/sofarsolar-g3_0.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -147,4 +147,4 @@ render:
host: 192.0.2.2 # Hostname
port: 8899 # Port
capacity: 50 # Battery capacity in kWh (optional)
defaultmode: 0 # optional
defaultmode: 0 # Default mode for battery control. Valid values are 0 (self use), 1 (time of use), 2 (timing mode), 4 (peak-shaving mode) (optional)
2 changes: 1 addition & 1 deletion templates/nightly/en/meter/sofarsolar-g3_1.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -147,4 +147,4 @@ render:
host: 192.0.2.2 # Hostname
port: 8899 # Port
capacity: 50 # Battery capacity in kWh (optional)
defaultmode: 0 # optional
defaultmode: 0 # Default mode for battery control. Valid values are 0 (self use), 1 (time of use), 2 (timing mode), 4 (peak-shaving mode) (optional)
2 changes: 1 addition & 1 deletion templates/nightly/en/meter/sofarsolar-g3_2.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -147,4 +147,4 @@ render:
host: 192.0.2.2 # Hostname
port: 8899 # Port
capacity: 50 # Battery capacity in kWh (optional)
defaultmode: 0 # optional
defaultmode: 0 # Default mode for battery control. Valid values are 0 (self use), 1 (time of use), 2 (timing mode), 4 (peak-shaving mode) (optional)
2 changes: 1 addition & 1 deletion templates/nightly/en/meter/sofarsolar-g3_3.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -147,4 +147,4 @@ render:
host: 192.0.2.2 # Hostname
port: 8899 # Port
capacity: 50 # Battery capacity in kWh (optional)
defaultmode: 0 # optional
defaultmode: 0 # Default mode for battery control. Valid values are 0 (self use), 1 (time of use), 2 (timing mode), 4 (peak-shaving mode) (optional)
2 changes: 1 addition & 1 deletion templates/nightly/en/meter/solax_0.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -146,4 +146,4 @@ render:
host: 192.0.2.2 # Hostname
port: 502 # Port
capacity: 50 # Battery capacity in kWh (optional)
defaultmode: 0 # optional
defaultmode: 0 # Default mode for battery control to which the inverter falls back after charging the battery or after stopping discharge. (optional)
2 changes: 1 addition & 1 deletion templates/nightly/en/meter/solax_1.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -146,4 +146,4 @@ render:
host: 192.0.2.2 # Hostname
port: 502 # Port
capacity: 50 # Battery capacity in kWh (optional)
defaultmode: 0 # optional
defaultmode: 0 # Default mode for battery control to which the inverter falls back after charging the battery or after stopping discharge. (optional)

0 comments on commit faab998

Please sign in to comment.