Skip to content

Commit

Permalink
Templates update for release evcc-io/evcc@597eeeb
Browse files Browse the repository at this point in the history
  • Loading branch information
andig committed Dec 18, 2024
1 parent d772b22 commit 9a6ba5f
Show file tree
Hide file tree
Showing 28 changed files with 26 additions and 28 deletions.
2 changes: 1 addition & 1 deletion templates/release/de/charger/livo_0.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -3,7 +3,7 @@ product:
description: Livo
requirements: ["eebus"]
description: |
Das Gerät benötigt eine feste IP Adresse.
Das Gerät benötigt eine feste IP Adresse. Es ist wichtig, zuerst EEBus einzurichten. Danach erkennt das Ladegerät evcc als HEMS-Gerät im Netzwerk. Verwende das Installationstool, um evcc als HEMS auszuwählen. Kopiere anschließend den angegebenen SKI aus der Installations-App und fügen ihn zu Ihrem YAML hinzu.
render:
- default: |
type: template
Expand Down
2 changes: 0 additions & 2 deletions templates/release/de/meter/fronius-gen24_0.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -16,7 +16,6 @@ render:
usage: grid
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 502 # Port (optional)
maxchargerate: 100 # Leistungslimit für Netzladung. (optional)
- usage: pv
default: |
type: template
Expand All @@ -31,7 +30,6 @@ render:
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 502 # Port (optional)
maxacpower: 0 # Maximale AC Leistung des Hybrid-Wechselrichters (optional)
maxchargerate: 100 # Leistungslimit für Netzladung. (optional)
- usage: battery
default: |
type: template
Expand Down
2 changes: 0 additions & 2 deletions templates/release/de/meter/fronius-gen24_1.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -16,7 +16,6 @@ render:
usage: grid
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 502 # Port (optional)
maxchargerate: 100 # Leistungslimit für Netzladung. (optional)
- usage: pv
default: |
type: template
Expand All @@ -31,7 +30,6 @@ render:
host: 192.0.2.2 # IP-Adresse oder Hostname
port: 502 # Port (optional)
maxacpower: 0 # Maximale AC Leistung des Hybrid-Wechselrichters (optional)
maxchargerate: 100 # Leistungslimit für Netzladung. (optional)
- usage: battery
default: |
type: template
Expand Down
5 changes: 3 additions & 2 deletions templates/release/de/meter/huawei-sun2000_0.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -58,7 +58,7 @@ render:
port: 502 # Port
timeout: 15s # optional
storageunit: 1 # optional
maxchargepower: 10000 # Leistungslimit für Netzladung. (optional)
forceaccharging: false # AC-Laden bleibt aktiv zum Laden des Speichers aus anderen AC Quellen für Wechselrichterkaskaden. Verhindert Stand-by. (optional)
- usage: pv
default: |
type: template
Expand Down Expand Up @@ -109,7 +109,7 @@ render:
port: 502 # Port
timeout: 15s # optional
storageunit: 1 # optional
maxchargepower: 10000 # Leistungslimit für Netzladung. (optional)
forceaccharging: false # AC-Laden bleibt aktiv zum Laden des Speichers aus anderen AC Quellen für Wechselrichterkaskaden. Verhindert Stand-by. (optional)
- usage: battery
default: |
type: template
Expand Down Expand Up @@ -162,3 +162,4 @@ render:
storageunit: 1 # optional
maxchargepower: 10000 # Leistungslimit für Netzladung. (optional)
capacity: 50 # Akkukapazität in kWh (optional)
forceaccharging: false # AC-Laden bleibt aktiv zum Laden des Speichers aus anderen AC Quellen für Wechselrichterkaskaden. Verhindert Stand-by. (optional)
1 change: 1 addition & 0 deletions templates/release/de/meter/kostal-plenticore-hw0200_0.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -53,4 +53,5 @@ render:
port: 1502 # Port
endianness: little # optional
capacity: 50 # Akkukapazität in kWh (optional)
maxchargerate: 100 # Leistungslimit für Netzladung. (optional)
watchdog: 60s # optional
2 changes: 0 additions & 2 deletions templates/release/de/meter/saj-h2_0.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -49,7 +49,6 @@ render:
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
defaultmode: 2 # optional
minsoc: 20 # Ladung mit maximaler Geschwindigkeit bis zu dem angegeben Ladestand unabhängig PV-Erzeugung, wenn der Lademodus nicht auf 'Aus' steht (optional)
maxsoc: 95 # optional
- usage: pv
Expand Down Expand Up @@ -99,7 +98,6 @@ render:
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
defaultmode: 2 # optional
minsoc: 20 # Ladung mit maximaler Geschwindigkeit bis zu dem angegeben Ladestand unabhängig PV-Erzeugung, wenn der Lademodus nicht auf 'Aus' steht (optional)
maxsoc: 95 # optional
- usage: battery
Expand Down
2 changes: 0 additions & 2 deletions templates/release/de/meter/saj-h2_1.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -49,7 +49,6 @@ render:
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
defaultmode: 2 # optional
minsoc: 20 # Ladung mit maximaler Geschwindigkeit bis zu dem angegeben Ladestand unabhängig PV-Erzeugung, wenn der Lademodus nicht auf 'Aus' steht (optional)
maxsoc: 95 # optional
- usage: pv
Expand Down Expand Up @@ -99,7 +98,6 @@ render:
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
defaultmode: 2 # optional
minsoc: 20 # Ladung mit maximaler Geschwindigkeit bis zu dem angegeben Ladestand unabhängig PV-Erzeugung, wenn der Lademodus nicht auf 'Aus' steht (optional)
maxsoc: 95 # optional
- usage: battery
Expand Down
1 change: 1 addition & 0 deletions templates/release/de/meter/senec-home_0.yaml
Original file line number Diff line number Diff line change
@@ -1,6 +1,7 @@
product:
brand: SENEC
description: .Home
capabilities: ["battery-control"]
render:
- usage: grid
default: |
Expand Down
1 change: 1 addition & 0 deletions templates/release/de/meter/sofarsolar-g3_0.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -147,3 +147,4 @@ render:
host: 192.0.2.2 # Hostname
port: 8899 # Port
capacity: 50 # Akkukapazität in kWh (optional)
defaultmode: 0 # optional
1 change: 1 addition & 0 deletions templates/release/de/meter/sofarsolar-g3_1.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -147,3 +147,4 @@ render:
host: 192.0.2.2 # Hostname
port: 8899 # Port
capacity: 50 # Akkukapazität in kWh (optional)
defaultmode: 0 # optional
1 change: 1 addition & 0 deletions templates/release/de/meter/sofarsolar-g3_2.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -147,3 +147,4 @@ render:
host: 192.0.2.2 # Hostname
port: 8899 # Port
capacity: 50 # Akkukapazität in kWh (optional)
defaultmode: 0 # optional
1 change: 1 addition & 0 deletions templates/release/de/meter/sofarsolar-g3_3.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -147,3 +147,4 @@ render:
host: 192.0.2.2 # Hostname
port: 8899 # Port
capacity: 50 # Akkukapazität in kWh (optional)
defaultmode: 0 # optional
4 changes: 2 additions & 2 deletions templates/release/de/vehicle/ioBroker.bmw_0.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -10,14 +10,14 @@ render:
title: # Wird in der Benutzeroberfläche angezeigt (optional)
capacity: 50 # Akkukapazität in kWh (optional)
vin: WBMW... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind (optional)
uri: # HTTP(S) Adresse (optional)
uri: # HTTP(S) Adresse
advanced: |
type: template
template: ioBroker.bmw
title: # Wird in der Benutzeroberfläche angezeigt (optional)
capacity: 50 # Akkukapazität in kWh (optional)
vin: WBMW... # Erforderlich, wenn mehrere Fahrzeuge des Herstellers vorhanden sind (optional)
uri: # HTTP(S) Adresse (optional)
uri: # HTTP(S) Adresse
icon: car # Icon in der Benutzeroberfläche (optional)
phases: 3 # Die maximale Anzahl der Phasen welche genutzt werden können (optional)
mode: # Möglich sind Off, Now, MinPV und PV, oder leer wenn keiner definiert werden soll (optional)
Expand Down
2 changes: 1 addition & 1 deletion templates/release/de/vehicle/seat_0.yaml
Original file line number Diff line number Diff line change
@@ -1,6 +1,6 @@
product:
brand: Seat
description: CupraConnect Gen3 (Ateca, Leon, Formentor)
description: CupraConnect Gen3 (Ateca, Leon, Formentor, Tarraco)
render:
- default: |
type: template
Expand Down
2 changes: 1 addition & 1 deletion templates/release/en/charger/livo_0.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -3,7 +3,7 @@ product:
description: Livo
requirements: ["eebus"]
description: |
The device requires a fixed IP addres.
The device requires a fixed IP addres. It's important to set up EEBus first. After setting up EEBus the charger will recognize evcc as a HEMS device on the network. Please use the installer tool to select evcc as HEMS. After this has been done, copy the given SKI from the Install app and add it to your yaml.
render:
- default: |
type: template
Expand Down
2 changes: 0 additions & 2 deletions templates/release/en/meter/fronius-gen24_0.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -16,7 +16,6 @@ render:
usage: grid
host: 192.0.2.2 # IP address or hostname
port: 502 # Port (optional)
maxchargerate: 100 # Power limit for grid charging. (optional)
- usage: pv
default: |
type: template
Expand All @@ -31,7 +30,6 @@ render:
host: 192.0.2.2 # IP address or hostname
port: 502 # Port (optional)
maxacpower: 0 # Maximum AC power of the hybrid inverter (optional)
maxchargerate: 100 # Power limit for grid charging. (optional)
- usage: battery
default: |
type: template
Expand Down
2 changes: 0 additions & 2 deletions templates/release/en/meter/fronius-gen24_1.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -16,7 +16,6 @@ render:
usage: grid
host: 192.0.2.2 # IP address or hostname
port: 502 # Port (optional)
maxchargerate: 100 # Power limit for grid charging. (optional)
- usage: pv
default: |
type: template
Expand All @@ -31,7 +30,6 @@ render:
host: 192.0.2.2 # IP address or hostname
port: 502 # Port (optional)
maxacpower: 0 # Maximum AC power of the hybrid inverter (optional)
maxchargerate: 100 # Power limit for grid charging. (optional)
- usage: battery
default: |
type: template
Expand Down
5 changes: 3 additions & 2 deletions templates/release/en/meter/huawei-sun2000_0.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -58,7 +58,7 @@ render:
port: 502 # Port
timeout: 15s # optional
storageunit: 1 # optional
maxchargepower: 10000 # Power limit for grid charging. (optional)
forceaccharging: false # Keep AC charging active to charge the storage from other inverters via AC. Prevents stand-by. (optional)
- usage: pv
default: |
type: template
Expand Down Expand Up @@ -109,7 +109,7 @@ render:
port: 502 # Port
timeout: 15s # optional
storageunit: 1 # optional
maxchargepower: 10000 # Power limit for grid charging. (optional)
forceaccharging: false # Keep AC charging active to charge the storage from other inverters via AC. Prevents stand-by. (optional)
- usage: battery
default: |
type: template
Expand Down Expand Up @@ -162,3 +162,4 @@ render:
storageunit: 1 # optional
maxchargepower: 10000 # Power limit for grid charging. (optional)
capacity: 50 # Battery capacity in kWh (optional)
forceaccharging: false # Keep AC charging active to charge the storage from other inverters via AC. Prevents stand-by. (optional)
1 change: 1 addition & 0 deletions templates/release/en/meter/kostal-plenticore-hw0200_0.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -53,4 +53,5 @@ render:
port: 1502 # Port
endianness: little # optional
capacity: 50 # Battery capacity in kWh (optional)
maxchargerate: 100 # Power limit for grid charging. (optional)
watchdog: 60s # optional
2 changes: 0 additions & 2 deletions templates/release/en/meter/saj-h2_0.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -49,7 +49,6 @@ render:
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
defaultmode: 2 # optional
minsoc: 20 # Immediate charging with maximum power up to the defined state of charge independently from solar production if the charge mode is not set to 'Off' (optional)
maxsoc: 95 # optional
- usage: pv
Expand Down Expand Up @@ -99,7 +98,6 @@ render:
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
defaultmode: 2 # optional
minsoc: 20 # Immediate charging with maximum power up to the defined state of charge independently from solar production if the charge mode is not set to 'Off' (optional)
maxsoc: 95 # optional
- usage: battery
Expand Down
2 changes: 0 additions & 2 deletions templates/release/en/meter/saj-h2_1.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -49,7 +49,6 @@ render:
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
defaultmode: 2 # optional
minsoc: 20 # Immediate charging with maximum power up to the defined state of charge independently from solar production if the charge mode is not set to 'Off' (optional)
maxsoc: 95 # optional
- usage: pv
Expand Down Expand Up @@ -99,7 +98,6 @@ render:
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
defaultmode: 2 # optional
minsoc: 20 # Immediate charging with maximum power up to the defined state of charge independently from solar production if the charge mode is not set to 'Off' (optional)
maxsoc: 95 # optional
- usage: battery
Expand Down
1 change: 1 addition & 0 deletions templates/release/en/meter/senec-home_0.yaml
Original file line number Diff line number Diff line change
@@ -1,6 +1,7 @@
product:
brand: SENEC
description: .Home
capabilities: ["battery-control"]
render:
- usage: grid
default: |
Expand Down
1 change: 1 addition & 0 deletions templates/release/en/meter/sofarsolar-g3_0.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -147,3 +147,4 @@ render:
host: 192.0.2.2 # Hostname
port: 8899 # Port
capacity: 50 # Battery capacity in kWh (optional)
defaultmode: 0 # optional
1 change: 1 addition & 0 deletions templates/release/en/meter/sofarsolar-g3_1.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -147,3 +147,4 @@ render:
host: 192.0.2.2 # Hostname
port: 8899 # Port
capacity: 50 # Battery capacity in kWh (optional)
defaultmode: 0 # optional
1 change: 1 addition & 0 deletions templates/release/en/meter/sofarsolar-g3_2.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -147,3 +147,4 @@ render:
host: 192.0.2.2 # Hostname
port: 8899 # Port
capacity: 50 # Battery capacity in kWh (optional)
defaultmode: 0 # optional
1 change: 1 addition & 0 deletions templates/release/en/meter/sofarsolar-g3_3.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -147,3 +147,4 @@ render:
host: 192.0.2.2 # Hostname
port: 8899 # Port
capacity: 50 # Battery capacity in kWh (optional)
defaultmode: 0 # optional
4 changes: 2 additions & 2 deletions templates/release/en/vehicle/ioBroker.bmw_0.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -10,14 +10,14 @@ render:
title: # Will be displayed in the user interface (optional)
capacity: 50 # Battery capacity in kWh (optional)
vin: WBMW... # Required if you own multiple vehicles of the same brand (optional)
uri: # HTTP(S) address (optional)
uri: # HTTP(S) address
advanced: |
type: template
template: ioBroker.bmw
title: # Will be displayed in the user interface (optional)
capacity: 50 # Battery capacity in kWh (optional)
vin: WBMW... # Required if you own multiple vehicles of the same brand (optional)
uri: # HTTP(S) address (optional)
uri: # HTTP(S) address
icon: car # Icon as shown in user interface (optional)
phases: 3 # The maximum number of phases which can be used (optional)
mode: # Possible values are Off, Now, MinPV and PV, or empty if none should be set (optional)
Expand Down
2 changes: 1 addition & 1 deletion templates/release/en/vehicle/seat_0.yaml
Original file line number Diff line number Diff line change
@@ -1,6 +1,6 @@
product:
brand: Seat
description: CupraConnect Gen3 (Ateca, Leon, Formentor)
description: CupraConnect Gen3 (Ateca, Leon, Formentor, Tarraco)
render:
- default: |
type: template
Expand Down

0 comments on commit 9a6ba5f

Please sign in to comment.