Skip to content

emryys/Microwave-analysis

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

7 Commits
 
 
 
 
 
 
 
 
 
 

Repository files navigation

Microwave-analysis

Matching Networks and Stub Tuning

You can find the required transmission line length and stub length by only inputing load impedance and charecteristic impedance of the transmission line.

Stubs are realized both open circuit and short circuit.

Note : All numerical values is presented in terms of lamda of the transmission line

Example :

What is Z0 : 50

What is stub charecteristic impeadance? : 75

What is ZL : 100+80j

d1 = %first solution or second solution it is arbitrary

0.2134 %length from load to stub

lo1 = %length from open circuit towards generator for 1 solution

0.3238

ls1 = %length from short circuit towards generator for 1 solution

0.0738

d2 = %first solution or second solution it is arbitrary

0.3697

lo2 = %length from open circuit towards generator for 2 solution

0.1762

ls2 = %length from short circuit towards generator for 2 solution

0.4262

NOTE : This is only to ease the calculations. Not practical use can be found.(For example : single frequency)