Notifications
You must be signed in to change notification settings - Fork 1
Binary sensor
Jens Østergaard Nielsen edited this page Jan 13, 2018
·
8 revisions
Before you can use the IHC Binary Sensor platform, you must setup the IHC Component
To configure IHC Binary Sensors insert this section in your configuration:
# Example configuration.yaml entry
binary_sensor:
- platform: ihc
When autosetup is enabled the following products will be found in the ihc project:
- Dataline magnet contacts
- Dataline Pir sensors
- Dataline Pir sensors with twilight detection
- Dataline Pir alarm sensor
- Dataline smoke detector
- Dataline gas detector
- Dataline light sensor
If you want to add something manually do it like this:
binary_sensor:
- platform: ihc
binary_sensors:
- id: 12345:
name: mysensor
type: opening
inverting: True
- id: 12346
...
Configuration variables:
- binary_sensors (Optional): List of binary sensors to setup manually.
- id (Required): The IHC resource id.
- inverting (Optional): If True the sensor will be inverted. Default False.
- name (Optional): The name of the component.
- type (Optional): The binary sensor type. See Home Assistant binary sensor for available types.
The resource id should be an id of a boolean resource.
The different kind of sensor types can be found here at the HA site: