15 changes: 13 additions & 2 deletions firmware/klipper_configurations/Octopus/Voron2_Octopus_Config.cfg
Original file line number Diff line number Diff line change
Expand Up @@ -12,9 +12,11 @@
## *** THINGS TO CHANGE/CHECK: ***
## MCU paths [mcu] section
## Thermistor types [extruder] and [heater_bed] sections - See https://www.klipper3d.org/Config_Reference.html#common-thermistors for common thermistor types
## Hotend heater pin [extruder] section
## Z Endstop Switch location [safe_z_home] section
## Homing end position [gcode_macro G32] section
## Z Endstop Switch offset for Z0 [stepper_z] section
## Stepper Z1 enable pin [stepper_z1] section
## Probe points [quad_gantry_level] section
## Min & Max gantry corner postions [quad_gantry_level] section
## PID tune [extruder] and [heater_bed] sections
Expand Down Expand Up @@ -168,7 +170,10 @@ stealthchop_threshold: 0
[stepper_z1]
step_pin: PG4
dir_pin: PC1
enable_pin: !PA0
## Octopus 1.0 & 1.1. Octopus PRO 1.0
#enable_pin: !PA0
## Octopus PRO 1.1
#enable_pin: !PA2
rotation_distance: 40
gear_ratio: 80:16
microsteps: 32
Expand Down Expand Up @@ -243,7 +248,10 @@ microsteps: 32
full_steps_per_rotation: 200 #200 for 1.8 degree, 400 for 0.9 degree
nozzle_diameter: 0.400
filament_diameter: 1.75
heater_pin: PA2
## Octopus 1.0 & 1.1. Octopus PRO 1.0
#heater_pin: PA2
## Octopus PRO 1.1
#heater_pin: PA0
## Check what thermistor type you have. See https://www.klipper3d.org/Config_Reference.html#common-thermistors for common thermistor types.
## Use "Generic 3950" for NTC 100k 3950 thermistors
#sensor_type:
Expand Down Expand Up @@ -373,7 +381,10 @@ heater: heater_bed

## Chamber Lighting - HE2 Connector (Optional)
#[output_pin caselight]
##Octopus 1.0 & 1.1, Octopus PRO 1.0
#pin: PB10
##Octopus PRO 1.1
#pin: PB0
#pwm:true
#shutdown_value: 0
#value:1
Expand Down