You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
This is great work you have done by collecting the values! Here the strategy would be following:
There are backgrounds which are more and backgrounds which are less important - the number of counts (as you know is A*eps -> activity times efficiency). I would identify which ones should contribute the most and investigate the precision of these values first.
Bkg processes activities:
List of relevant bkg processes is listed in #28
!Note: this needs to be thoroughly checked!
Pa234m_foil_bulk
=> 8.19 / 1000 / 10, # [mBq/kg] from Steven's thesis, better case (table7.4)Bi214_foil_bulk
=> 10 / 1_000_000 , # [μBq/kg] converted to [Bq/kg] from SN measurementsBi214_foil_surface
=> 150 / 1_000_000 , # [μBq/m3] converted to [Bq/m3] from SN measurements; gas volume 15m3Bi214_wire_surface
=> 150 / 1_000_000 , # [μBq/m3] converted to [Bq/m3] from SN measurements; gas volume 15m3Bi214_wire_bulk
=> 0.00001 , # MOCK VALUEBi214_PMT_glass_bulk
=> 140 / 286, # [Bq/kg] originally the value is given as 417Bq, I just divide by PMT weight hereTl208_foil_bulk
=> 2 / 1_000_000 , # [μBq/kg] converted to [Bq/kg] from SN measurementsTl208_foil_surface
=> 150 / 1_000_000 , # [μBq/m3] converted to [Bq/m3] from SN measurements; gas volume 15m3Tl208_PMT_glass_bulk
=> 41.4 / 286 , # [Bq/kg] originally the value is given as 41.4Bq, I just divide by PMT weight hereBi210_foil_bulk
=> 10 / 1_000_000 , # MOCK VALUEBi210_foil_surface
=> 150 / 1_000_000 , # [μBq/m3] converted to [Bq/m3] from SN measurements; gas volume 15m3Bi210_wire_surface
=> 150 / 1_000_000 , # [μBq/m3] converted to [Bq/m3] from SN measurements; gas volume 15m3Bi210_wire_bulk
=> 0.00001 , # MOCK VALUEK40_foil_bulk
=> 53.59 / 1000 / 10, # [mBq/kg] from Steven's thesis, better case (table7.4)K40_PMT_glass_bulk
=> 417 / 286 , # [Bq/kg] originally the value is given as 417Bq, I just divide by PMT weight hereBi214_hall_surface
=> 0.5 / 500 / 500 , # [μBq] Value is taken from Xalbat (flux) divided twice by 500 - for tof cut and for shielding effectTl208_hall_surface
=> 2.4 / 500 /500 , # [μBq] Value is taken from Xalbat (flux) divided twice by 500 - for tof cut and for shielding effectK40_hall_surface
=> 1.2 / 500 / 500 , # [μBq] Value is taken from Xalbat (flux) divided twice by 500 - for tof cut and for shielding effectSignal processes
List of relevant signal processes is listed in #28
The text was updated successfully, but these errors were encountered: