description: This article mainly introduces how to use the 485 communication function of reComputer R1000, and tests the rs485 and Modbus communication functions.
title: How to use rs485 and modbus rtu with reComputer R1000
title: How to use rs485 and modbus with reComputer R1000
keywords:
- Edge
- reComputer R1000
Expand Down Expand Up @@ -64,6 +64,11 @@ sudo apt-get install minicom
This test uses an RS485 to USB module to connect reComputer R1000 and W10 PC.
<div align="center"><img src="https://files.seeedstudio.com/wiki/reComputer-R1000/RS485_fix/hardwareconnection.png" alt="pir" width="700" height="auto" /></div>

For ModbusTCP, we use Ethernet cables to connect the W10 PC and reComputer R1000 to a switch to ensure that they are on the same network segment.

<div align="center"><img src="https://files.seeedstudio.com/wiki/reComputer-R1000/fuxa/r1000_connection.png" alt="pir" width="500" height="auto" /></div>


## Steps to use the RS485 interface normally and perform Modbus RTU testing

**Step 1**: First, you need to download the [**C program**](https://github.com/Seeed-Studio/seeed-linux-dtoverlays/tree/master/tools/rs485_control_DE) provided by us, and then refer to the contents of the ReadMe. Compile and run.
Expand Down Expand Up @@ -117,6 +122,23 @@ echo 590 > /sys/class/gpio/unexport
This is because they use different file systems and there will be conflicts when accessing the same resource.
:::

## Steps to use the Modbus TCP testing

**Step 1**: Open modbusmechanic on Win10 PC and R1000

<center><img width={600} src="https://files.seeedstudio.com/wiki/reComputer-R1000/fuxa/modbusmac_two.png" /></center>

**Step 2**: R1000 acts as the modbus TCP host. Click `Tool => Start Slave Simulator` on W10 PC, select `TCP` for TYPE, select `1` for Slave ID, and then add `Coils`; then enter `IP` in R1000, and select `Read Coil` for Scan group. Enter `Slave Node` and `Register`, and finally click `Transmit packet`. You can see that the slave data has been successfully read.

<center><img width={600} src="https://files.seeedstudio.com/wiki/reComputer-R1000/fuxa/R1000_MASTER_MODBUS_TCP.gif" /></center>

**Step 3**: R1000 acts as a modbus TCP slave. Refer to the second step for configuration. You can see that R1000 can read data normally as a slave.

<center><img width={600} src="https://files.seeedstudio.com/wiki/reComputer-R1000/fuxa/R1000_SLAVE_MODBUS_TCP.gif" /></center>


Running the Modbus TCP slave program in R1000 needs to listen to the `502` port, which may require `sudo` permissions. If your application cannot listen to the `502` port, please try to add permissions to it.