Notifications
You must be signed in to change notification settings - Fork 24
Hardware Hacking Guide
Some Grove modules' hardware design is not natively compatible with Wio device, but can be remedied by workaround or hacking. In this guide, we will show you how to hack un-supported Grove to work with Wio.
Fail on Wio Link, Wio Node
To use Grove - Encoder
, you need either using battery to power the board or some manual soldering workaround.
This is due to the RX pin of UART socket is pulled up to CP2102's TX pin and we put Grove - Encoder
onto this UART socket. The pulling up may interact with the signal from encoder. We can fix this by shorting the resistor R1
to enhance the pulling down of the encoder signal.
You can just solder off R1
and then short the two pads of R1
with a chunk of tin. Or, you can solder a jump wire onto the two pads of R1
.
Fail on Wio Link, Wio Node
The Grove - LCD RGB Backlight
works under 5V. But the communication signals can be compatible with Wio Link/Node's 3.3V voltage. So the thing we need to do is, power the Grove - LCD RGB Backlight
with a 5V, e.g. We can grab 5V from USB. Please pull out this Grove while OTA the Wio device.
Now found Wio Node I2C1 is not work, so use I2C0 port.
Fail on Wio Link, Wio Node
Same as the Grove - LCD RGB Backlight
, the Grove - Dust Sensor
needs 5V power supply too. But the signal pin of Grove - Dust Sensor
outputs 5V which will interfere in the GPIO of Wio Link/Node. The interaction may cause Wio Link/Node unable to OTA update its firmware. So we need inserting a 1K𝛀 resistor on the SIG
line of Grove - Dust Sensor
.
Fail on Wio Link, Wio Node
The Grove - SPDT Relay(30A)
works under 5V. But the communication signals can be compatible with Wio Link/Node's 3.3V voltage. We need to power the Grove - SPDT Relay(30A)
with a 5V, e.g. We can grab 5V from USB. Please pull out this Grove while OTA the Wio device.
TBC📶🆖