Releases: NOVACProject/MobileDOAS
Releases · NOVACProject/MobileDOAS
v6.5.0
Release 6.5.0 of the MobileDOAS software, with support for both OceanOptics and Avantes spectrometers.
Notice that there are here two builds of the software, one with support for OceanOptics and one with support for Avantes. Rationale is that the build with support for a specific manufacturer requires the device drivers for that manufacturer to be installed on the computer, or the software will crash. Separate builds makes it possible to require only installing drivers for one manufacturer.
v6.3.1
v6.3
v6.2
v6.1
Critical changes
- Enable configuration and evaluation of second channel for spectrometers that support it (#8)
- Removed support for text format configuration file.
New features
- Start GPS - for reading GPS data; in debug mode only
- Multiple reference files can be addeded or removed simultaneously through evaluation configuration dialogs
- Legend for real-time route dialog (#67)
- Remove extended format attributes in STD that were previously coded with 0. (#71)
- Update Plume Height and Wind Measurement dialogs to read two evaluation logs (#73)
- Warn user (audio and visual) when GPS connection is lost (#78)
- Reduce number of spectra collected for characterization of the offset in adaptive mode (#87)
- Option to disable audio in spectrometer configuration (#88)
- Alter pitch based on column density, instead of volume, if supported by audio device (#88)
- Use same tone for negative column values (#88)
- Limit maximum exposure time in 'adaptive' mode to time-resolution of measurement (#100)
- Support for QE65000 (#101)
- Support user configurable range for saturation ratio in adaptive mode (#109)
Bug fixes
- Ensure evaluation configuration dialog updates properly when adding/removing a new fit window
- Attempt to reconnect when GPS connection is lost (#77)
- Added GPS lat/lon validation (#81)
- Fix for bad GPS date in STD files (#86)
- Fix date in STD file from View Spectrometer Output (#104)
- Restore 'Dark' tab in ReEvaluate dialog (#116)
v6.0
Critical changes
- Support for 64-bit OS
New features
- Add option to remove points with intensity higher than a certain threshold (#17)
- Use another color (cyan) for fit resolve in Fit Window (#19)
- Auto-scale real-time route (#20)
- Automatically change flux calculations when unit is changed (#23)
- Display absolute values for final plume width and flux calculations (#24, #25)
- Add support for re-evaluation of measurements taken in adaptive mode (#26)
- Add Altitude to .STD files (#32)
Bug fixes
- Fix issue with list of references not updating in Configuration Dialog->Evalute (#11)
- Validate lat/lon values after focus is removed from field in Post Flux Calculation dialog (#14)
- Fix issue with intensity slide bar on main page not always showing up (#21)
- Fix date problem with measurements spanning midnight UTC (#27)
- Fix Altitude showing up as 0.0 in evaluation logs (#29)
- Fix "Could not communicate with the GPS" error popping up behind main UI (#31)
- Fix multiples of same tab being generated in Post Flux Calculation dialog when 'File->ReEvaluate This Log File' is selected (#34)
- Add message for user when Post-Wind calculations are not supported (#39)
- Fix compatibility with high DPI display (#47)
- Fix issue with reading GPS data off of COM ports above 9 (#53)
Removal of unused features