ngraziano
Copy link
Contributor

Description

Configuration update for AnyCubic Vyper

Benefits

  • Activate cooling fan for extruder 0, with actual config the fan never start (I don't understand why this is commented)
  • Activate tare with value from OEM firmware, it is needed for the probing to complete. If not set the filament pull on the head and the probe fail when the head is in the middle.
  • Disable leveling fade by default (like OEM firmware), because the the probed position is more than 2 mm bellow the zero point and using the printer just after G29 cause massive z error with actual value of 10

Related Issues

None

For probing to succeed tare must be done for each point.
The probing is more than 2mm below home Z position
so fading can not be use without an offset.
@thinkyhead
Copy link
Member

Thanks for the patches! This will be a great boon to users of Marlin on Vyper. Maybe that E0 auto fan pin was commented because the original author wasn't confident….? Anyway, good to have it working properly!

@thinkyhead thinkyhead merged commit 5eb004e into MarlinFirmware:import-2.1.x Jun 9, 2024