#RaspberryPI

Application which reads the Hewalex Sunboiler, and the Intergas heater; readible via ModBUS.

The Hewalex Sunboiler is connected via RS232, via an FTDI <> RS485 Converter The Intergas module is connected via an FTDI <> RS232 module. The ModBUS is connected via an FTD <> RS485 Converter.

More info will come; also the code will be improved, as this is just the first scratch.

The application is written in C++ in a Visual Studio 2022 IDE. This is cross-compiled on a Raspberry PI (3B), with the default Raspbian image.

ModBUS address table

Addres 1 (The server)

Address Name
1 Intergas Sent
2 Intergas Received
3 Intergas Timeouts
4 Hewalex Sent
5 Hewalex Received
6 Hewalex Timeouts
7 P1 Sent (not used)
8 P1 Received
9 P1 Timeout
10 Status

Address 2 (Intergas)

Address Name
2 Exhaust temperature
4 Source temperature
6 Return temperature
8 Hot water temperature
10 Boiler temperature
12 Outside temperature
14 Pressure
16 Temperature setpoint
18 Fan speed setpoint
20 Fan speed
22 Fan PWM
24 Ionisation current
26 Status code
28 Status byte 1
30 Status byte 2
36 Line power connected
38 Power connected times
40 Heating hours
42 Hot water hours
44 Burner starts (total)
46 Ignition failed
48 Flame loss
50 Resets
52 Gas meter heating
54 Gas meter hot water
56 Water meter
58 Burner starts heating (Hot water)
60 Heater on
61 Comfort mode
62 Central heating setpoint
63 Hot water setpoint
64 Eco days
65 Comfort setpoint
66 Hot water night
67 Central heating night
68 Parameter 1
69 Parameter 2
70 Parameter 3
71 Parameter 4
72 Parameter 5
73 Parameter 6
74 Parameter 7
75 Parameter 8
76 Parameter 9
77 Parameter A
78 Parameter B
79 Parameter C
80 Parameter C
81 Parameter D
82 Parameter E
83 Parameter E.
84 Parameter F
85 Parameter H
86 Parameter N
87 Parameter O
88 Parameter P
90 Parameter F.
91 Parameter heating flow
92 Parameter O.
93 Cascade reaction
94 Parameter 5.
95 Parameter C.
96 Parameter 3.
97 Parameter P.
100 Fault 1 times
101 Fault 1 times
102 Fault 2 times
103 Fault 3 times
104 Fault 4 times
105 Fault 5 times
106 Fault 6 times
107 Fault 7 times
108 Fault 8 times
109 Fault 9 times
110 Fault 10 times
111 Fault 11 times
112 Fault 12 times
113 Fault 13 times
114 Fault 14 times
115 Fault 15 times
116 Fault 16 times
117 Fault 17 times
118 Fault 18 times
119 Fault 19 times
120 Fault 20 times
121 Fault 21 times
122 Fault 22 times
123 Fault 23 times
124 Fault 24 times
125 Fault 25 times
126 Fault 26 times
127 Fault 27 times
128 Fault 28 times
129 Fault 29 times
130 Fault 30 times
131 Fault 31 times

Addres 3 (Hewalex Sunboiler)

Address Name
120 Date
124 Time
128 T1
130 T2
132 T3
134 T4
136 T5
138 T6
144 Collector Power (W)
148 Consumption
150 Collector active
152 Flow Rate
154 Pumps
156 Collector Pump Speed
166 Total Energy
170 Installation Scheme
172 Display Timeout
174 Display Brightness
176 Alarm Sound Enabled
178 Key Sound Enabled
180 Display Language
182 Fluid Freezing Temp
186 Flow Rate Nominal
188 Flow Rate Measurement
190 Flow Rate Weight
192 Holiday Enabled
194 Holiday Start Day
196 Holiday Start Month
198 Holiday Start Year
200 Holiday End Day
202 Holiday End Month
204 Holiday End Year
206 Collector Type
208 Collector Pump Hysteresis
210 Extra Pump Hysteresis
212 Collector Pump Max Temp
214 Boiler Pump Min Temp
218 Heat Source Max Temp
220 Boiler Pump Max Temp
222 Pump Regulation Enabled
226 Heat Source Max Collector Power
228 Collector Overheat Prot Enabled
230 Collector Overheat Prot Max Temp
232 Collector Freezing Prot Enabled
234 Heating Priority
236 Legionella Prot Enabled
238 Lock Boiler K With Boiler C
240 Night Cooling Enabled
242 Night Cooling Start Temp
244 Night Cooling Stop Temp
246 Night Cooling Stop Time
248 Time Program CM-F
252 Time Program CSat
256 Time Program CSun
260 Time Program KM-F
264 Time Program KSat
268 Time Program KSun
278 Collector Pump Min Rev
280 Collector Pump Max Rev
282 Collector Pump Min Inc Time
284 Collector Pump Min Dec Time
286 Collector Pump Startup Speed
288 Pressure Switch Enabled
290 Tank Overheat Prot Enabled
322 Circulation Pump Enabled
324 Circulation Pump Mode
326 Circulation Pump Min Temp
328 Circulation Pump ON Time
330 Circulation Pump OFF Time
312 Total Operation Time
320 Reg320

Address 4 (P1 Meter)

Address Name
2 Consumed low tariff
4 Consumed high tariff
6 Returned low tariff
8 Returned high tariff
10 Short power failure count
12 Long power failure count
14 Short power failure duration
16 Long power failure duration
18 Gas
20 Actual consumption
22 Actual return
24 Actual consumption L1
26 Actual consumption L2
28 Actual consumption L3
30 Actual return L1
32 Actual return L2
34 Actual return L3
36 Current L1
38 Current L2
40 Current L3
42 Voltage L1
44 Voltage L2
46 Voltage L3
48 Tariff

About

ModBUS server for Hewalex and Intergas