Skip to content

HeewonChung92/CardiacRehabExercise

Repository files navigation

Cardiac Rehab Exercise

The data presents an efficient self-cardiac rehabilitation(CR) exercise system. The system consists of a wearable device, a smartphone application, and a medical station. A patient performs self-CR exercise with the worn wearable device which enables the patient to do self-CR exercise by informing current exercise stage and recommending appropriate exercise intensity in real-time.

The exercise stage order consists of warm-up, main exercise, rest, and cool-down as recommended by ACSM guidelines. A patient performs the self-CR exercise with the worn wearable device on wrist. The wearable device measures instantaneous HRs during the exercise, and informs a patient an appropriate exercise intensity based on the comparison between the current HR and the Target Heartrate Zone(THZ) in real-time.

The system was validated with 16 healthy subjects: a CR specialist remotely monitors the exercise records and prescribes the CR exercise through a medical station, which automatically ransmits the prescription to a patient's wearable device via smartphone application.

Cardiac Rehabilitation Exercise Data with Matlab

Heewon Chung, Hooseok Lee, and Jinseok Lee (Professor) a member of BAMI LAB.
https://sites.google.com/site/bamilab/biosignal-lab
Last updated 2018.09.11 (September 11, 2018)

CR Exercise Experiment Protocol

Measurements were taken using an ECG placed on the chest together with a PPG placed on the wrist during CR Exercise. ECG data were recorded simultaneously using a 24-hour Holter monitor (SEER Light; GE Healthcare, Milwaukee, WI, USA). PPG and motion data were recorded using a wearable device which we developed. Participants were asked to perform the exercise according to the exercise protocol, we have designed.

  1. Stay (Resting) : 1minutes
  2. Walking : 2minutes, treadmill (3km/h)
  3. Running : 3minutes, treadmill (7km/h)
  4. Walking : 2minutes, treadmill (3km/h)
  5. Running : 3minutes, treadmill (8km/h)
  6. Walking : 2minutes, treadmill (3km/h)
  7. Stay (Resting) : 1minutes

Matlab Data

This database contains wrist PPGs recorded during stay, walking, and running. Accelerometers and Gyroscopes are collected to remove the motion artifact from the PPGs. A reference chest ECG is included to allow a gold-standard comparison of heart rate during CR exercise.

ECG sampling rate : 125Hz
PPG sampling rate : 50Hz
Acc sampling rate : 50Hz
Gyro sampling rate : 50Hz

Data Description

bpmECG : ECG heart rate
timeECG : ECG times
sigPPG : PPG signal
sigAcc : Accelerometer signal
sigGyro : Gyroscope signal

About

Cardiac Rehabilitation Exercise Data

Topics

Resources

Stars

Watchers

Forks

Releases

No releases published

Packages

No packages published