Notifications
You must be signed in to change notification settings - Fork 1
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
Merge pull request #70 from FAIRmat-NFDI/update-configs-after-mpes-ch…
…anges Update configs and data after mpes changes
- Loading branch information
Showing
32 changed files
with
488 additions
and
488 deletions.
There are no files selected for viewing
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
Binary file not shown.
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -1,142 +1,142 @@ | ||
title: XPS Experiment | ||
start_time: 2022-04-08T11:47:02.0200Z | ||
end_time: 2022-04-08T12:32:06.0200Z | ||
program_name: SpecsLab 2 | ||
user: | ||
name: Lukas Pielsticker | ||
affiliation: Max Planck Institute for Chemical Energy Conversion | ||
email: [email protected] | ||
instrument: | ||
device_information: | ||
vendor: SPECS GmbH | ||
model: XPS setup | ||
identifier: null | ||
energy_resolution: | ||
type: calibrated | ||
resolution: | ||
value: 0.2 | ||
unit: eV | ||
source_xray: | ||
type: Synchrotron X-ray Source | ||
probe: x-ray | ||
device_information: | ||
vendor: null | ||
model: null | ||
identifier: null | ||
beam_xray: | ||
distance: | ||
value: 0.0 | ||
unit: mm | ||
analyser: | ||
description: hemispherical | ||
name: PHOIBOS 150 | ||
device_information: | ||
vendor: SPECS GmbH | ||
model: PHOIBOS 150 | ||
identifier: null | ||
collectioncolumn: | ||
scheme: angular dispersive | ||
device_information: | ||
vendor: null | ||
model: null | ||
identifier: null | ||
energydispersion: | ||
scheme: hemispherical | ||
energy_scan_mode: fixed_analyser_transmission | ||
diameter: | ||
unit: mm | ||
value: 150 | ||
device_information: | ||
vendor: null | ||
model: null | ||
identifier: null | ||
detector: | ||
amplifier_type: channeltron | ||
detector_type: Multi-anode | ||
manipulator: | ||
device_information: | ||
vendor: SPECS GmbH | ||
model: 5-axis manipulator | ||
identifier: null | ||
temperature_sensor: | ||
name: type K thermocouple | ||
measurement: temperature | ||
attached_to: sample | ||
type: type K thermocouple | ||
value: | ||
value: 298.0 | ||
unit: K | ||
sample_heater: | ||
name: Coherent Compact Evolution IR Diode LASER (DILAS) | ||
physical_quantity: temperature | ||
type: IR diode laser | ||
heater_power: | ||
value: 0.0 | ||
unit: W | ||
pid: | ||
setpoint: | ||
value: 298.0 | ||
unit: K | ||
cryostat: | ||
name: null | ||
physical_quantity: null | ||
type: null | ||
pid: | ||
setpoint: null | ||
drain_current_amperemeter: | ||
name: Amperemeter 1.0 | ||
measurement: current | ||
type: wire | ||
value: | ||
value: 0.0 | ||
unit: A | ||
sample_bias_voltmeter: | ||
name: XPS sample voltmeter | ||
measurement: voltage | ||
attached_to: sample | ||
type: oscilloscope | ||
value: | ||
value: 0.0 | ||
unit: V | ||
sample_bias_potentiostat: | ||
name: XPS sample potentiostat | ||
physical_quantity: voltage | ||
type: potentiostat | ||
pid: | ||
setpoint: | ||
value: 0.0 | ||
unit: V | ||
pressure_gauge: | ||
name: Atmion | ||
measurement: pressure | ||
type: hot-filament ionization gauge | ||
value: | ||
value: 0.000000001 | ||
unit: mbar | ||
value_log: | ||
value: | ||
value: null | ||
unit: null | ||
flood_gun: | ||
name: FG 22/35 | ||
physical_quantity: current | ||
type: low energy electron source | ||
current: | ||
value: 0.0 | ||
unit: A | ||
current_log: | ||
value: | ||
value: null | ||
unit: null | ||
sample: | ||
description: CoO powder | ||
substance: | ||
molecular_formula_hill: CoO | ||
situation: vacuum | ||
history: | ||
sample_preparation: | ||
start_time: 2022-04-08T11:02:38.0200Z | ||
end_time: 2022-04-08T11:06:42.200Z | ||
description: From third party | ||
method: null | ||
title: XPS Experiment | ||
start_time: 2022-04-08T11:47:02.0200Z | ||
end_time: 2022-04-08T12:32:06.0200Z | ||
program_name: SpecsLab 2 | ||
user: | ||
name: Lukas Pielsticker | ||
affiliation: Max Planck Institute for Chemical Energy Conversion | ||
email: [email protected] | ||
instrument: | ||
device_information: | ||
vendor: SPECS GmbH | ||
model: XPS setup | ||
identifier: null | ||
energy_resolution: | ||
type: calibrated | ||
resolution: | ||
value: 0.2 | ||
unit: eV | ||
source_xray: | ||
type: Synchrotron X-ray Source | ||
probe: x-ray | ||
device_information: | ||
vendor: null | ||
model: null | ||
identifier: null | ||
beam_xray: | ||
distance: | ||
value: 0.0 | ||
unit: mm | ||
analyser: | ||
description: hemispherical | ||
name: PHOIBOS 150 | ||
device_information: | ||
vendor: SPECS GmbH | ||
model: PHOIBOS 150 | ||
identifier: null | ||
collectioncolumn: | ||
scheme: angular dispersive | ||
device_information: | ||
vendor: null | ||
model: null | ||
identifier: null | ||
energydispersion: | ||
scheme: hemispherical | ||
energy_scan_mode: fixed_analyser_transmission | ||
diameter: | ||
unit: mm | ||
value: 150 | ||
device_information: | ||
vendor: null | ||
model: null | ||
identifier: null | ||
detector: | ||
amplifier_type: channeltron | ||
detector_type: Multi-anode | ||
manipulator: | ||
device_information: | ||
vendor: SPECS GmbH | ||
model: 5-axis manipulator | ||
identifier: null | ||
temperature_sensor: | ||
name: type K thermocouple | ||
measurement: temperature | ||
attached_to: sample | ||
type: type K thermocouple | ||
value: | ||
value: 298.0 | ||
unit: K | ||
sample_heater: | ||
name: Coherent Compact Evolution IR Diode LASER (DILAS) | ||
physical_quantity: temperature | ||
type: IR diode laser | ||
heater_power: | ||
value: 0.0 | ||
unit: W | ||
pid: | ||
setpoint: | ||
value: 298.0 | ||
unit: K | ||
cryostat: | ||
name: null | ||
physical_quantity: null | ||
type: null | ||
pid: | ||
setpoint: null | ||
drain_current_amperemeter: | ||
name: Amperemeter 1.0 | ||
measurement: current | ||
type: wire | ||
value: | ||
value: 0.0 | ||
unit: A | ||
sample_bias_voltmeter: | ||
name: XPS sample voltmeter | ||
measurement: voltage | ||
attached_to: sample | ||
type: oscilloscope | ||
value: | ||
value: 0.0 | ||
unit: V | ||
sample_bias_potentiostat: | ||
name: XPS sample potentiostat | ||
physical_quantity: voltage | ||
type: potentiostat | ||
pid: | ||
setpoint: | ||
value: 0.0 | ||
unit: V | ||
pressure_gauge: | ||
name: Atmion | ||
measurement: pressure | ||
type: hot-filament ionization gauge | ||
value: | ||
value: 0.000000001 | ||
unit: mbar | ||
value_log: | ||
value: | ||
value: null | ||
unit: null | ||
flood_gun: | ||
name: FG 22/35 | ||
physical_quantity: current | ||
type: low energy electron source | ||
current: | ||
value: 0.0 | ||
unit: A | ||
current_log: | ||
value: | ||
value: null | ||
unit: null | ||
sample: | ||
description: CoO powder | ||
substance: | ||
molecular_formula_hill: CoO | ||
situation: vacuum | ||
history: | ||
sample_preparation: | ||
start_time: 2022-04-08T11:02:38.0200Z | ||
end_time: 2022-04-08T11:06:42.200Z | ||
description: From third party | ||
method: null | ||
|
Oops, something went wrong.