forked from php/php-src
-
Notifications
You must be signed in to change notification settings - Fork 0
/
UPGRADING.INTERNALS
166 lines (135 loc) · 6.58 KB
/
UPGRADING.INTERNALS
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
PHP 7.4 INTERNALS UPGRADE NOTES
1. Internal API changes
a. php_sys_symlink() and php_sys_link()
b. zend_lookup_class_ex() and zend_fetch_class_by_name()
c. Function/property/class flags
d. Removed zend_check_private()
e. php_win32_error_to_msg() memory management
f. get_properties_for() handler / Z_OBJDEBUG_P
g. Required object handlers
h. Immutable classes and op_arrays
2. Build system changes
a. Abstract
b. Unix build system changes
c. Windows build system changes
3. Module changes
a. ext/xml
b. ext/hash
========================
1. Internal API changes
========================
a. php_sys_symlink() and php_sys_link() portability macros have been
added, which behave like POSIX's symlink() and link(), respectively, on
POSIX compliant systems and on Windows.
b. zend_lookup_class_ex() and zend_fetch_class_by_name() prototypes were
changed to accept optional lower-case class name as zend_string*,
instead of zval*.
c. Function/property/class flags changes
- ZEND_ACC_CTOR and ZEND_ACC_DTOR are removed. It's possible to check if
method is a constructor/destructor using the following condition
(func->common.scope->constructor == func).
- ZEND_ACC_IMPLEMENTED_ABSTRACT is removed (it was used only internally
during inheritance).
- ZEND_ACC_IMPLICIT_PUBLIC is removed (it was used only for reflection)
- ZEND_ACC_SHADOW property flag is removed. Instead of creating shadow
clone, now we use the same private property_info, and should also
check property_info->ce (in the same way as with methods).
- ZEND_ACC_ANON_BOUND is replaced with ZEND_ACC_LINKED. This flag is set
not only during anonymous classes declaration, but also during any
run-time or compile-time class declaration.
- ZEND_ACC_NO_RT_ARENA renamed into ZEND_ACC_HEAP_RT_CACHE. Now it's used
not only for closures, but also for pseudo-main op_arrays.
- ZEND_ACC_... flags are re-numbered.
d. zend_check_private() is removed. Use (func->common.scope == scope) instead.
e. Pointers returned by php_win32_error_to_msg() have to be freed using
php_win32_error_msg_free(). Same regarding php_win_err() vs.
php_win_err_free().
f. A new, optional object handler with the signature
HashTable *get_properties_for(zval *obj, zend_prop_purpose purpose)
has been introduced, where zend_prop_purpose (currently) takes one of:
ZEND_PROP_PURPOSE_DEBUG // var_dump etc.
ZEND_PROP_PURPOSE_ARRAY_CAST // (array) $obj
ZEND_PROP_PURPOSE_SERIALIZE // "O"-format serialization (__wakeup)
ZEND_PROP_PURPOSE_VAR_EXPORT // var_export (__set_state)
ZEND_PROP_PURPOSE_JSON // json_encode
The handler returns a non-null HashTable with increased refcounted, and
the return value must be released using zend_release_properties().
This handler serves the same general function as get_properties(), but
provides more control over different property uses, while also making
it possible to return a temporary property table.
get_properties() is still used in cases where none of the above purposes
apply, but overloading get_properties() is generally discouraged. If you
want to provide purposes for general usage rather than just debugging or
serialization, please prefer using properly declared properties.
get_debug_info() is superseded by get_properties_for() with the
ZEND_PROP_PURPOSE_DEBUG purpose, but remains available for backwards-
compatibility reasons. However, while it is fine to define this handler,
it should never be directly called by consuming code.
The Z_OBJDEBUG_P macro has been removed. It should be replaced by calls to
zend_get_properties_for() with the ZEND_PROP_PURPOSE_DEBUG purpose:
// OLD
int is_temp;
HashTable *ht = Z_OBJDEBUG_P(obj, is_temp);
// ...
if (is_temp) {
zend_hash_destroy(ht);
FREE_HASHTABLE(ht);
}
// NEW
HashTable *ht = zend_get_properties_for(obj, ZEND_PROP_PURPOSE_DEBUG);
// ...
zend_release_properties(ht);
g. The following object handlers are now required (must be non-NULL):
* free_obj
* dtor_obj
* read_property
* write_property
* read_dimension
* write_dimension
* get_property_ptr_ptr
* has_property
* unset_property
* has_dimension
* unset_dimension
* get_properties
* get_method
* get_constructor
* get_class_name
* get_gc
It is recommended to initialize object handler structures by copying the
std object handlers and only overwriting those you want to change.
h. Opcache may make classes and op_arrays immutable. Such classes are marked
by ZEND_ACC_IMMUTABLE flag, they are not going to be copied from opcache
shared memory to process memory and must not be modified at all.
Few related data structures were changed to allow addressing mutable data
structures from immutable ones. This access is implemented through
ZEND_MAP_PTR... abstraction macros and, basically, uses additional level of
indirection. op_array->run_time_cache, op_array->static_variables_ptr and
class_entry->static_members_table now have to be accessed through
ZEND_MAP_PTR... macros.
It's also not allowed to change op_array->reserved[] handles of immutable
op_arrays. Instead, now you have to reserve op_array handle using
zend_get_op_array_extension_handle() during MINIT and access its value
using ZEND_OP_ARRAY_EXTENSION(op_array, handle).
========================
2. Build system changes
========================
a. Abstract
- The hash extension is now always available, meaning the --enable-hash
configure argument has been removed.
b. Unix build system changes
- configure --help now also outputs --program-suffix and --program-prefix
information by using the Autoconf AC_ARG_PROGRAM macro.
- Obsolescent macros AC_FUNC_VPRINTF and AC_FUNC_UTIME_NULL have been
removed. Symbols HAVE_VPRINTF and HAVE_UTIME_NULL are no longer defined
since they are not needed on the current systems.
c. Windows build system changes
========================
3. Module changes
========================
a. ext/xml
- The public (internal) API of the ext/xml extension has been removed. All
functions and structures are private to the extension now.
b. ext/hash
- The hash extension is now always available, allowing extensions to rely
on its functionality to be available without compile time checks.