The binary
data format parser parses binary protocols into metrics using
user-specified configurations.
[[inputs.file]]
files = ["example.bin"]
## Data format to consume.
## Each data format has its own unique set of configuration options, read
## more about them here:
## https://github.com/influxdata/telegraf/blob/master/docs/DATA_FORMATS_INPUT.md
data_format = "binary"
## Do not error-out if none of the filter expressions below matches.
# allow_no_match = false
## Specify the endianness of the data.
## Available values are "be" (big-endian), "le" (little-endian) and "host",
## where "host" means the same endianness as the machine running Telegraf.
# endianness = "host"
## Interpret input using the specified encoding
## Available values are "none" (raw bytes), "hex" and "base64"
# binary_encoding = "none"
## Multiple parsing sections are allowed
[[inputs.file.binary]]
## Optional: Metric (measurement) name to use if not extracted from the data.
# metric_name = "my_name"
## Definition of the message format and the extracted data.
## Please note that you need to define all elements of the data in the
## correct order with the correct length as the data is parsed in the order
## given.
## An entry can have the following properties:
## name -- Name of the element (e.g. field or tag). Can be omitted
## for special assignments (i.e. time & measurement) or if
## entry is omitted.
## type -- Data-type of the entry. Can be "int8/16/32/64", "uint8/16/32/64",
## "float32/64", "bool" and "string".
## In case of time, this can be any of "unix" (default), "unix_ms", "unix_us",
## "unix_ns" or a valid Golang time format.
## bits -- Length in bits for this entry. If omitted, the length derived from
## the "type" property will be used. For "time" 64-bit will be used
## as default.
## assignment -- Assignment of the gathered data. Can be "measurement", "time",
## "field" or "tag". If omitted "field" is assumed.
## omit -- Omit the given data. If true, the data is skipped and not added
## to the metric. Omitted entries only need a length definition
## via "bits" or "type".
## terminator -- Terminator for dynamic-length strings. Only used for "string" type.
## Valid values are "fixed" (fixed length string given by "bits"),
## "null" (null-terminated string) or a character sequence specified
## as HEX values (e.g. "0x0D0A"). Defaults to "fixed" for strings.
## timezone -- Timezone of "time" entries. Only applies to "time" assignments.
## Can be "utc", "local" or any valid Golang timezone (e.g. "Europe/Berlin")
entries = [
{ type = "string", assignment = "measurement", terminator = "null" },
{ name = "address", type = "uint16", assignment = "tag" },
{ name = "value", type = "float64" },
{ type = "unix", assignment = "time" },
]
## Optional: Filter evaluated before applying the configuration.
## This option can be used to mange multiple configuration specific for
## a certain message type. If no filter is given, the configuration is applied.
# [inputs.file.binary.filter]
# ## Filter message by the exact length in bytes (default: N/A).
# # length = 0
# ## Filter the message by a minimum length in bytes.
# ## Messages longer of of equal length will pass.
# # length_min = 0
# ## List of data parts to match.
# ## Only if all selected parts match, the configuration will be
# ## applied. The "offset" is the start of the data to match in bits,
# ## "bits" is the length in bits and "match" is the value to match
# ## against. Non-byte boundaries are supported, data is always right-aligned.
# selection = [
# { offset = 0, bits = 8, match = "0x1F" },
# ]
#
#
In this configuration mode, you explicitly specify the field and tags you want to scrape out of your data.
A configuration can contain multiple binary
subsections for e.g. the file
plugin to process the binary data multiple times. This can be useful
(together with filters) to handle different message types.
Please note: The filter
section needs to be placed after the entries
definitions due to TOML constraints as otherwise the entries will be assigned
to the filter section.
By specifying allow_no_match
you allow the parser to silently ignore data
that does not match any given configuration filter. This can be useful if
you only want to collect a subset of the available messages.
This specifies the endianness of the data. If not specified, the parser will
fallback to the "host" endianness, assuming that the message and Telegraf
machine share the same endianness.
Alternatively, you can explicitly specify big-endian format ("be"
) or
little-endian format ("le"
).
If this option is not specified or set to none
, the input data contains the
binary data as raw bytes. This is the default.
If set to hex
, the input data is interpreted as a string containing
hex-encoded data like C0 C7 21 A9
. The value is case insensitive and can
handle spaces and prefixes like 0x
or x
.
If set to base64
the input data is interpreted as a string containing
padded base64 data RDLAAA==
.
In both, filter
and entries
definitions, values can be extracted at non-byte
boundaries. You can for example extract 3-bit starting at bit-offset 8. In those
cases, the result will be masked and shifted such that the resulting byte-value
is right aligned. In case your 3-bit are 101
the resulting byte value is
0x05
.
This is especially important when specifying the match
value in the filter
section.
The entry array specifies how to dissect the message into the measurement name, the timestamp, tags and fields.
When setting the assignment
to "measurement"
, the extracted value
will be used as the metric name, overriding other specifications.
The type
setting is assumed to be "string"
and can be omitted similar
to the name
option. See string
type handling
for details and further options.
When setting the assignment
to "time"
, the extracted value
will be used as the timestamp of the metric. By default the current
time will be used for all created metrics.
The type
setting here contains the time-format can be set to unix
,
unix_ms
, unix_us
, unix_ns
, or an accepted
Go "reference time". Consult the Go time
package for details and additional examples on how to set the time format.
If type
is omitted the unix
format is assumed.
For the unix
format and derivatives, the underlying value is assumed
to be a 64-bit integer. The bits
setting can be used to specify other
length settings. All other time-formats assume a fixed-length string
value to be extracted. The length of the string is automatically
determined using the format setting in type
.
The timezone
setting allows to convert the extracted time to the
given value timezone. By default the time will be interpreted as utc
.
Other valid values are local
, i.e. the local timezone configured for
the machine, or valid timezone-specification e.g. Europe/Berlin
.
When setting the assignment
to "tag"
, the extracted value
will be used as a tag. The name
setting will be the name of the tag
and the type
will default to string
. When specifying other types,
the extracted value will first be interpreted as the given type and
then converted to string
.
The bits
setting can be used to specify the length of the data to
extract and is required for fixed-length string
types.
When setting the assignment
to "field"
or omitting the assignment
setting, the extracted value will be used as a field. The name
setting
is used as the name of the field and the type
as type of the field value.
The bits
setting can be used to specify the length of the data to
extract. By default the length corresponding to type
is used.
Please see the string and bool
specific sections when using those types.
Strings are assumed to be fixed-length strings by default. In this case, the
bits
setting is mandatory to specify the length of the string in bit.
To handle dynamic strings, the terminator
setting can be used to specify
characters to terminate the string. The two named options, fixed
and null
will specify fixed-length and null-terminated strings, respectively.
Any other setting will be interpreted as hexadecimal sequence of bytes
matching the end of the string. The termination-sequence is removed from
the result.
By default bool
types are assumed to be one bit in length. You can
specify any other length by using the bits
setting.
When interpreting values as booleans, any zero value will be false
,
while any non-zero value will result in true
.
Parts of the data can be omitted by setting omit = true
. In this case,
you only need to specify the length of the chunk to omit by either using
the type
or bits
setting. All other options can be skipped.
Filters can be used to match the length or the content of the data against
a specified reference. See the examples section for details.
You can also check multiple parts of the message by specifying multiple
section
entries for a filter. Each section
is then matched separately.
All have to match to apply the configuration.
Using the length
option, the filter will check if the data to parse has
exactly the given number of bytes. Otherwise, the configuration will not
be applied.
Similarly, for length_min
the data has to have at least the given number
of bytes to generate a match.
Selections can be used with or without length constraints to match the content
of the data. Here, the offset
and bits
properties will specify the start
and length of the data to check. Both values are in bit allowing for non-byte
aligned value extraction. The extracted data will the be checked against the
given match
value specified in HEX.
If multiple selection
entries are specified all of the selections must
match for the configuration to get applied.
In the following example, we use a binary protocol with three different messages in little-endian format
+--------+------+------+--------+--------+------------+--------------------+--------------------+
| ID | type | len | addr | count | failure | value | timestamp |
+--------+------+------+--------+--------+------------+--------------------+--------------------+
| 0x0201 | 0x0A | 0x18 | 0x7F01 | 0x2A00 | 0x00000000 | 0x6F1283C0CA210940 | 0x10D4DF6200000000 |
+--------+------+------+--------+--------+------------+--------------------+--------------------+
+--------+------+------+------------+
| ID | type | len | value |
+--------+------+------+------------+
| 0x0201 | 0x0B | 0x04 | 0xDEADC0DE |
+--------+------+------+------------+
+--------+------+------+------------+------------+--------------------+
| ID | type | len | value x | value y | timestamp |
+--------+------+------+------------+------------+--------------------+
| 0x0201 | 0x0C | 0x10 | 0x4DF82D40 | 0x5F305C08 | 0x10D4DF6200000000 |
+--------+------+------+------------+------------+--------------------+
All messages consists of a 4-byte header containing the message type in the 3rd byte and a message specific body. To parse those messages you can use the following configuration
[[inputs.file]]
files = ["messageA.bin", "messageB.bin", "messageC.bin"]
data_format = "binary"
endianness = "le"
[[inputs.file.binary]]
metric_name = "messageA"
entries = [
{ bits = 32, omit = true },
{ name = "address", type = "uint16", assignment = "tag" },
{ name = "count", type = "int16" },
{ name = "failure", type = "bool", bits = 32, assignment = "tag" },
{ name = "value", type = "float64" },
{ type = "unix", assignment = "time" },
]
[inputs.file.binary.filter]
selection = [{ offset = 16, bits = 8, match = "0x0A" }]
[[inputs.file.binary]]
metric_name = "messageB"
entries = [
{ bits = 32, omit = true },
{ name = "value", type = "uint32" },
]
[inputs.file.binary.filter]
selection = [{ offset = 16, bits = 8, match = "0x0B" }]
[[inputs.file.binary]]
metric_name = "messageC"
entries = [
{ bits = 32, omit = true },
{ name = "x", type = "float32" },
{ name = "y", type = "float32" },
{ type = "unix", assignment = "time" },
]
[inputs.file.binary.filter]
selection = [{ offset = 16, bits = 8, match = "0x0C" }]
The above configuration has one [[inputs.file.binary]]
section per
message type and uses a filter in each of those sections to apply
the correct configuration by comparing the 3rd byte (containing
the message type). This will lead to the following output
metricA,address=383,failure=false count=42i,value=3.1415 1658835984000000000
metricB value=3737169374i 1658847037000000000
metricC x=2.718280076980591,y=0.0000000000000000000000000000000006626070178575745 1658835984000000000
where metricB
uses the parsing time as timestamp due to missing
information in the data. The other two metrics use the timestamp
derived from the data.