Both sensors reporting beer temp #400

Open
Hugo-Pereira opened this issue May 25, 2023 · 6 comments
Open

Both sensors reporting beer temp #400

Hugo-Pereira opened this issue May 25, 2023 · 6 comments

Comments

@Hugo-Pereira
Copy link

Hugo-Pereira commented May 25, 2023

Greetings!

On my latest brew, I'm experiencing the weirdest bug. After some time, brewpi starts registering the fridge temperature being the same as beer temperature. This is causing the heater to run way longer than it should, having my fermentation chamber reached more than 60ºC!
My wiring seems correct, and the brewpi bahaves correctly for hours, until randomly it decides to stop reading the fridge temperature.

See image attached. Look at what happens at around 20:20. I'm on version 4.2. What could be causing the issue?
image

Thanks in advance

@Daniel-Magg
Copy link

Daniel-Magg commented Jun 6, 2023

I have seen the same issue. Power cycling seems to fix the problem.
Would be nice if the system stopped heating/cooling, when the chamber sensor is either stuck or cannot be read.

@Hugo-Pereira
Copy link
Author

I changed the resistence on the temperature probes to 2k2 and the issue hasn't happened again on my tests. I'll report again how it goes on my next brew

@Daniel-Magg
Copy link

Daniel-Magg commented Jun 29, 2023

Ok, thanks, I might try that.

It happened to me yesterday again and I have observed that in the device list the value for the chamber temperature sensor was blank (after refreshing the device list). So it should be possible to detect this condition in SW and disable the control system.
I'm using the Thorrak PCBs (surface mount main PCB and RJ-45 breakout board).
My configuration is:
Device 0, device slot 0, HW type sensor, function Beer Temp
Device 1, device slot 1, HW type sensor, function Chamber Temp
Device 2, device slot 2, HW type sensor, function Room Temp
Device 3, device slot 3, HW type pin (inverted), function Chamber Cooler
Device 4, device slot 4, HW type pin (inverted), function Chamber Heater

@Hugo-Pereira
Copy link
Author

Yes I've also seen that on the device list.
Personally I'd love an option to reboot automatically.
E.g. if we're logging, and the device has been on for more than 1 hour, and we lost one of the probes, reboot.
Rebooting always fixed the issue, but only temporarily.

Lets hope the 2k2 fixes it though. I also added a capacitor on the probes for good measure.

@Hugo-Pereira
Copy link
Author

It's been 5 days and I've got no issues to report. Seems that the 2k2 resistor solved it! (Or the capacitor, or both)

@Hugo-Pereira
Copy link
Author

I thappened again. This time it took almost 2 weeks though, so it's an improvement (or maybe luck!)