BandPass filter poles do not match the description on schematic #4

Open
kevinjwalters opened this issue Jan 16, 2024 · 1 comment
Open

Comments

@kevinjwalters
Copy link

kevinjwalters commented Jan 16, 2024

The v0.3 schematic describes the active filter as a BandPass filter (72Hz - 720Hz).

If I calculate the poles of the filter I get 159.15 and 723.43, the lower value does not match, why is that? I found an online bode plotter http://sim.okawa-denshi.jp/en/optool.php and it agrees with the frequencies I calculate.

udl-muscle-bioamp-v0 3-bpfilter-values

udl-muscle-bioamp-v0 3-bpfilter-bodeplot

@lorforlinux
Copy link
Member

Hey @kevinjwalters, we are using 2.2uF on the production board of Muscle BioAmp Shield. Thus you are seeing 72Hz-720Hz on the specifications. I will update the schematic to reflect this production change.