Skip to content

Commit 8ad3c1f

Browse files
committed
mb/system76/rpl,mtl: Use Software Connection Manager
Support for Firmware Connection Manager is being removed by Intel. Barlow Ridge will require SCM. Use SCM on units with iTBT controller. Maple Ridge does not support SCM, so models with dTBT are not changed. Change-Id: Ib11c5e66e6877f93145dd6643d3436a16efe8ddf Signed-off-by: Tim Crawford <[email protected]>
1 parent de34980 commit 8ad3c1f

File tree

2 files changed

+12
-4
lines changed

2 files changed

+12
-4
lines changed

src/mainboard/system76/mtl/Kconfig

Lines changed: 6 additions & 2 deletions
Original file line numberDiff line numberDiff line change
@@ -31,13 +31,15 @@ config BOARD_SYSTEM76_DARP10
3131
select MAINBOARD_USES_IFD_GBE_REGION
3232
select SOC_INTEL_ENABLE_USB4_PCIE_RESOURCES
3333
select SOC_INTEL_METEORLAKE_U_H
34+
select DEFAULT_SOFTWARE_CONNECTION_MANAGER
3435

3536
config BOARD_SYSTEM76_DARP10_B
3637
select BOARD_SYSTEM76_MTL_COMMON
3738
select EC_SYSTEM76_EC_FAN2
3839
select MAINBOARD_USES_IFD_GBE_REGION
3940
select SOC_INTEL_ENABLE_USB4_PCIE_RESOURCES
4041
select SOC_INTEL_METEORLAKE_U_H
42+
select DEFAULT_SOFTWARE_CONNECTION_MANAGER
4143

4244
config BOARD_SYSTEM76_DARP11
4345
select BOARD_SYSTEM76_MTL_COMMON
@@ -57,15 +59,17 @@ config BOARD_SYSTEM76_LEMP13
5759
select BOARD_SYSTEM76_MTL_COMMON
5860
select DRIVERS_I2C_TAS5825M
5961
select HAVE_SPD_IN_CBFS
60-
select SOC_INTEL_METEORLAKE_U_H
6162
select SOC_INTEL_ENABLE_USB4_PCIE_RESOURCES
63+
select SOC_INTEL_METEORLAKE_U_H
64+
select DEFAULT_SOFTWARE_CONNECTION_MANAGER
6265

6366
config BOARD_SYSTEM76_LEMP13_B
6467
select BOARD_SYSTEM76_MTL_COMMON
6568
select DRIVERS_I2C_TAS5825M
6669
select HAVE_SPD_IN_CBFS
67-
select SOC_INTEL_METEORLAKE_U_H
6870
select SOC_INTEL_ENABLE_USB4_PCIE_RESOURCES
71+
select SOC_INTEL_METEORLAKE_U_H
72+
select DEFAULT_SOFTWARE_CONNECTION_MANAGER
6973

7074
if BOARD_SYSTEM76_MTL_COMMON
7175

src/mainboard/system76/rpl/Kconfig

Lines changed: 6 additions & 2 deletions
Original file line numberDiff line numberDiff line change
@@ -63,13 +63,15 @@ config BOARD_SYSTEM76_BONW15_B
6363

6464
config BOARD_SYSTEM76_DARP9
6565
select BOARD_SYSTEM76_RPL_COMMON
66-
select PCIEXP_HOTPLUG
6766
select SOC_INTEL_ALDERLAKE_PCH_P
67+
select SOC_INTEL_ENABLE_USB4_PCIE_RESOURCES
68+
select DEFAULT_SOFTWARE_CONNECTION_MANAGER
6869

6970
config BOARD_SYSTEM76_GALP7
7071
select BOARD_SYSTEM76_RPL_COMMON
71-
select PCIEXP_HOTPLUG
7272
select SOC_INTEL_ALDERLAKE_PCH_P
73+
select SOC_INTEL_ENABLE_USB4_PCIE_RESOURCES
74+
select DEFAULT_SOFTWARE_CONNECTION_MANAGER
7375

7476
config BOARD_SYSTEM76_GAZE18
7577
select BOARD_SYSTEM76_RPL_COMMON
@@ -83,6 +85,7 @@ config BOARD_SYSTEM76_LEMP12
8385
select HAVE_SPD_IN_CBFS
8486
select SOC_INTEL_ALDERLAKE_PCH_P
8587
select SOC_INTEL_ENABLE_USB4_PCIE_RESOURCES
88+
select DEFAULT_SOFTWARE_CONNECTION_MANAGER
8689

8790
config BOARD_SYSTEM76_ORYP11
8891
select BOARD_SYSTEM76_RPL_COMMON
@@ -91,6 +94,7 @@ config BOARD_SYSTEM76_ORYP11
9194
select EC_SYSTEM76_EC_DGPU
9295
select SOC_INTEL_ALDERLAKE_PCH_P
9396
select SOC_INTEL_ENABLE_USB4_PCIE_RESOURCES
97+
select DEFAULT_SOFTWARE_CONNECTION_MANAGER
9498

9599
config BOARD_SYSTEM76_ORYP12
96100
select BOARD_SYSTEM76_RPL_COMMON

0 commit comments

Comments
 (0)