Skip to content

Commit 2d03f83

Browse files
committed
mb/system76/rpl,mtl: Use Software Connection Manager
Support for Firmware Connection Manager is being removed by Intel. Barlow Ridge will require SCM. Use SCM on units with iTBT controller. Maple Ridge does not support SCM, so models with dTBT are not changed. Change-Id: Ib11c5e66e6877f93145dd6643d3436a16efe8ddf Signed-off-by: Tim Crawford <[email protected]>
1 parent 7c024f8 commit 2d03f83

File tree

2 files changed

+12
-4
lines changed

2 files changed

+12
-4
lines changed

src/mainboard/system76/mtl/Kconfig

Lines changed: 6 additions & 2 deletions
Original file line numberDiff line numberDiff line change
@@ -32,27 +32,31 @@ config BOARD_SYSTEM76_DARP10
3232
select MAINBOARD_USES_IFD_GBE_REGION
3333
select SOC_INTEL_ENABLE_USB4_PCIE_RESOURCES
3434
select SOC_INTEL_METEORLAKE_U_H
35+
select DEFAULT_SOFTWARE_CONNECTION_MANAGER
3536

3637
config BOARD_SYSTEM76_DARP10_B
3738
select BOARD_SYSTEM76_MTL_COMMON
3839
select EC_SYSTEM76_EC_FAN2
3940
select MAINBOARD_USES_IFD_GBE_REGION
4041
select SOC_INTEL_ENABLE_USB4_PCIE_RESOURCES
4142
select SOC_INTEL_METEORLAKE_U_H
43+
select DEFAULT_SOFTWARE_CONNECTION_MANAGER
4244

4345
config BOARD_SYSTEM76_LEMP13
4446
select BOARD_SYSTEM76_MTL_COMMON
4547
select DRIVERS_I2C_TAS5825M
4648
select HAVE_SPD_IN_CBFS
47-
select SOC_INTEL_METEORLAKE_U_H
4849
select SOC_INTEL_ENABLE_USB4_PCIE_RESOURCES
50+
select SOC_INTEL_METEORLAKE_U_H
51+
select DEFAULT_SOFTWARE_CONNECTION_MANAGER
4952

5053
config BOARD_SYSTEM76_LEMP13_B
5154
select BOARD_SYSTEM76_MTL_COMMON
5255
select DRIVERS_I2C_TAS5825M
5356
select HAVE_SPD_IN_CBFS
54-
select SOC_INTEL_METEORLAKE_U_H
5557
select SOC_INTEL_ENABLE_USB4_PCIE_RESOURCES
58+
select SOC_INTEL_METEORLAKE_U_H
59+
select DEFAULT_SOFTWARE_CONNECTION_MANAGER
5660

5761
if BOARD_SYSTEM76_MTL_COMMON
5862

src/mainboard/system76/rpl/Kconfig

Lines changed: 6 additions & 2 deletions
Original file line numberDiff line numberDiff line change
@@ -64,13 +64,15 @@ config BOARD_SYSTEM76_BONW15_B
6464

6565
config BOARD_SYSTEM76_DARP9
6666
select BOARD_SYSTEM76_RPL_COMMON
67-
select PCIEXP_HOTPLUG
6867
select SOC_INTEL_ALDERLAKE_PCH_P
68+
select SOC_INTEL_ENABLE_USB4_PCIE_RESOURCES
69+
select DEFAULT_SOFTWARE_CONNECTION_MANAGER
6970

7071
config BOARD_SYSTEM76_GALP7
7172
select BOARD_SYSTEM76_RPL_COMMON
72-
select PCIEXP_HOTPLUG
7373
select SOC_INTEL_ALDERLAKE_PCH_P
74+
select SOC_INTEL_ENABLE_USB4_PCIE_RESOURCES
75+
select DEFAULT_SOFTWARE_CONNECTION_MANAGER
7476

7577
config BOARD_SYSTEM76_GAZE18
7678
select BOARD_SYSTEM76_RPL_COMMON
@@ -84,6 +86,7 @@ config BOARD_SYSTEM76_LEMP12
8486
select HAVE_SPD_IN_CBFS
8587
select SOC_INTEL_ALDERLAKE_PCH_P
8688
select SOC_INTEL_ENABLE_USB4_PCIE_RESOURCES
89+
select DEFAULT_SOFTWARE_CONNECTION_MANAGER
8790

8891
config BOARD_SYSTEM76_ORYP11
8992
select BOARD_SYSTEM76_RPL_COMMON
@@ -92,6 +95,7 @@ config BOARD_SYSTEM76_ORYP11
9295
select EC_SYSTEM76_EC_DGPU
9396
select SOC_INTEL_ALDERLAKE_PCH_P
9497
select SOC_INTEL_ENABLE_USB4_PCIE_RESOURCES
98+
select DEFAULT_SOFTWARE_CONNECTION_MANAGER
9599

96100
config BOARD_SYSTEM76_ORYP12
97101
select BOARD_SYSTEM76_RPL_COMMON

0 commit comments

Comments
 (0)