The cause of the Firmware Update Verification Failure
is that the processors LOCKBITS were set. These need to be reset to NOLOCK
status.
##Things You Will Need
- AVRstudio 6.1 or later.
- AVRISP mkII Programmer (NOT A CLONE OR A KNOCKOFF)
- Windows Machine
- Launch AVRStudio 6.1
- Go to the
Tools
menu then theDevice Programming
- Now for the
Tool
selectAVRISP mkII
from the drop down menu. - Then select
ATxmega192A3
from the Device drop down menu. - Click
Apply
- Now select the
Lock bits
from the vertical list on the left. - Set ALL Values to
NOLOCK
. (See image below to see how this should look with the correctLOCKBITS
set.) - Click
Program
##Conclusion
With your LOCKBITS
correctly set you should be able to make it through the whole firmware update process.
Getting Started Pages
- Home
- What is TinyG?
- Getting Started
- Connecting TinyG
- Configuring TinyG
- Sending Gcode Files
- Flashing TinyG
- Chilipeppr
Reference Pages
- TinyG Help Page
- TinyG Tuning
- TinyG Command Line
- TinyG JSON
- Gcode Support
- Homing and Limits
- Inch and MM Units
- Alarms and Exceptions
- Coordinate Systems
- Status Codes
- Status Reports
- Power Management
- Feedhold and Resume
- Licensing
- TinyG v8 Data Sheet
Discussion Topics
- Test-Drive-TinyG
- Jerk Controlled Motion
- Gcode Parsing
- Shapeoko Setup
- OX CNC TinyG Guide
- Creating Gcode Files
- Milling With Noisy Spindles
- Stepper Motors and Power Supplies
- Text Wrappers and Transaction IDs
- Using External Drivers
- TinyG Projects
Chilipeppr
- Chilipeppr
- Chilipeppr Advanced Usage
- Chilipeppr Archive and Restore Parameters
- ChiliPeppr PCB Auto Level
- Automatic Z Homing When Milling PCBs
Troubleshooting
Developer Pages