MQTT Topics

The base topic, as configured in the web GUI is prepended to all follwing topics. [dtuserial] will be replaced with the serial number of the DTU. [serial] will be replaced with the serial number of the inverter. [1-N] will be replaced with the number of the output phase (for AC values ) or input string (for DC values).

General DTU topics

Topic(new) Topic (old) R / W Description Value / Unit
[dtuserial]/ip dtu/ip R IP address of OpenDTU IP address
[dtuserial]/hostname dtu/hostname R Current hostname of the dtu (as set in web GUI) string
[dtuserial]/rssi dtu/rssi R WiFi network quality db value
[dtuserial]/status dtu/status R Indicates whether OpenDTU network is reachable online / offline
[dtuserial]/uptime dtu/uptime R Time in seconds since startup seconds
[dtuserial]/git_hash R git hash of the current software version string

Mapped to InfluxDB as measurement ("table") dtu:

dtu field value timestamp
[dtuserial] ... ... ...

Valid fields: hostname | ip | rssi | status | uptime

Output (AC) per DTU

Enabled inverter means, that only inverters with "Poll inverter data" enabled are considered.

Topic(new) Topic (old) R / W Description Value / Unit
[dtuserial]/ac/power ac/power R Sum of AC active power of all enabled inverters W
[dtuserial]/ac/yieldtotal ac/yieldtotal R Sum of energy converted to AC since reset watt hours of all enabled inverters Kilo watt hours (kWh)
[dtuserial]/ac/yieldday ac/yieldday R Sum of energy converted to AC per day in watt hours of all enabled inverters Watt hours (Wh)
[dtuserial]/ac/is_valid ac/is_valid R Indicator whether all enabled inverters where reachable 0 or 1

Mapped to InfluxDB as measurement ("table") output_per_dtu:

dtu field value timestamp
[dtuserial] ... ... ...

Valid fields: power | yieldtotal | yieldday | is_valid

Please note that yieldday does not provide the daily production but it provides the production since last start of the inverter. If it gets cloudy and the inverter looses power during the day and restarts later, yieldday will only count since this point in time. The value stays even if the inverter loses power (cached in the DTU). This means in the hours after midnight, you get the reading of the previous day.

To calculate the power production in a period (e.g., a day), it is better to subtract the first value of yieldtotal in a period from the last value of yieldtotal in that period.

Input (DC) per DTU

Topic(new) Topic (old) R / W Description Value / Unit
[dtuserial]/dc/power dc/power R Sum of DC power of all enabled inverters Watt (W)
[dtuserial]/dc/current -- R
[dtuserial]/dc/irradiation dc/irradiation R Produced power of all enabled inverter stripes with defined irradiation settings divided by sum of all enabled inverters irradiation %
[dtuserial]/dc/is_valid dc/is_valid R Indicator whether all enabled inverters where reachable 0 or 1

Mapped to InfluxDB as measurement ("table") input_per_dtu:

dtu field value timestamp
[dtuserial] ... ... ...

Valid fields: power | irradiation | is_valid | current

Inverter specific topics

Topic(new) Topic (old) R / W Description Value / Unit
[dtuserial]/inverters/[serial]/name [serial]/name R Name of the inverter as configured in web GUI String
[dtuserial]/inverters/[serial]/devinfo/bootloaderversion [serial]/device/bootloaderversion R Bootloader version of the inverter
[dtuserial]/inverters/[serial]/devinfo/fwbuildversion [serial]/device/fwbuildversion R Firmware version of the inverter
[dtuserial]/inverters/[serial]/devinfo/fwbuilddatetime [serial]/device/fwbuilddatetime R Build date / time of inverter firmware
[dtuserial]/inverters/[serial]/devinfo/hwpartnumber [serial]/device/hwpartnumber R Hardware part number of the inverter
[dtuserial]/inverters/[serial]/devinfo/hwversion [serial]/device/hwversion R Hardware version of the inverter
[dtuserial]/inverters/[serial]/devinfo/maxpower R
[serial]/status/reachable R Indicates whether the inverter is reachable 0 or 1
[dtuserial]/inverters/[serial]/producing [serial]/status/producing R Indicates whether the inverter is producing AC power 0 or 1
[dtuserial]/inverters/[serial]/last_update [serial]/status/last_update R Unix timestamp of last inverter statistics udpate seconds since JAN 01 1970 (UTC)
[dtuserial]/inverters/[serial]/temperature [serial]/0/temperature R Temperature of inverter in degree celsius Degree Celsius (°C)
[dtuserial]/inverters/[serial]/limit_relative [serial]/status/limit_relative R Current applied production limit of the inverter % of total possible output
[dtuserial]/inverters/[serial]/limit_absolute [serial]/status/limit_absolute R Current applied production limit of the inverter Watt (W)
[dtuserial]/inverters/[serial]/uptime R
[dtuserial]/inverters/[serial]/status R

Mapped to InfluxDB as measurement ("table") inverter:

dtu inverter field value timestamp
[dtuserial] [serial] ... ... ...

Valid fields: name | bootloaderversion | fwbuildversion | fwbuilddatetime | hwpartnumber | hwversion | maxpower | producing | last_update | temperature | limit_relative | limit_absolute | uptime | status

Output (AC) per inverter

Topic(new) Topic (old) R / W Description Value / Unit
[dtuserial]/inverters/[serial]/ac/current [serial]/0/current R AC current in ampere Ampere (A)
[dtuserial]/inverters/[serial]/ac/power [serial]/0/power R AC active power in watts Watt (W)
[dtuserial]/inverters/[serial]/ac/yieldday [serial]/0/yieldday R Energy converted to AC per day in watt hours Watt hours (Wh)
[dtuserial]/inverters/[serial]/ac/yieldday [serial]/0/yieldtotal R Energy converted to AC since reset watt hours Kilo watt hours (kWh)
[dtuserial]/inverters/[serial]/ac/frequency [serial]/0/frequency R AC frequency in hertz Hertz (Hz)

Mapped to InfluxDB as measurement ("table") output_per_inverter:

dtu inverter field value timestamp
[dtuserial] [serial] ... ... ...

Valid fields: current | power | yieldday | yieldday | frequency

Input (DC) per inverter

Totals:

Topic(new) Topic (old) R / W Description Value / Unit
[dtuserial]/inverters/[serial]/dc/power [serial]/0/powerdc R DC power in watts Watt (W)
[dtuserial]/inverters/[serial]/dc/current R DC current Ampere (A)
[dtuserial]/inverters/[serial]/dc/irradiation R

Mapped to InfluxDB as measurement ("table") input_per_inverter:

dtu inverter field value timestamp
[dtuserial] [serial] ... ... ...

Valid fields: power

Output (AC) per inverter and phase

Topic(new) Topic (old) R / W Description Value / Unit
[dtuserial]/inverters/[serial]/phase/[1-N]/current [serial]/0/current R AC current in ampere Ampere (A)
[serial]/0/efficiency R Ratio AC Power over DC Power in percent %
[serial]/0/frequency R AC frequency in hertz Hertz (Hz)
[dtuserial]/inverters/[serial]/phase/[1-N]/power [serial]/0/power R AC active power in watts Watt (W)
[dtuserial]/inverters/[serial]/phase/[1-N]/powerfactor [serial]/0/powerfactor R Power factor in percent %
[dtuserial]/inverters/[serial]/phase/[1-N]/reactivepower [serial]/0/reactivepower R AC reactive power in VAr VAr
[dtuserial]/inverters/[serial]/phase/[1-N]/voltage [serial]/0/voltage R AC voltage in volt Volt (V)
[dtuserial]/inverters/[serial]/phase/[1-N]/yieldday [serial]/0/yieldday R Energy converted to AC per day in watt hours Watt hours (Wh)
[dtuserial]/inverters/[serial]/phase/[1-N]/yieldtotal [serial]/0/yieldtotal R Energy converted to AC since reset watt hours Kilo watt hours (kWh)
[dtuserial]/inverters/[serial]/phase/[1-N]/name R

Mapped to InfluxDB as measurement ("table") output:

dtu inverter phase field value timestamp
[dtuserial] [serial] [1-N] ... ... ...

Valid fields: current | power | powerfactor | reactivepower | voltage | yieldday | yieldday

Input (DC) per inverter and string

Topic(new) Topic (old) R / W Description Value / Unit
[dtuserial]/inverters/[serial]/string/[1-N]/current [serial]/[1-4]/current R DC current of specific input in ampere Ampere (A)
[dtuserial]/inverters/[serial]/string/[1-N]/name [serial]/[1-4]/name R Name of the DC input channel as configured in web GUI
[dtuserial]/inverters/[serial]/string/[1-N]/irradiation [serial]/[1-4]/irradiation R Ratio DC Power over set maximum power (in web GUI) %
[dtuserial]/inverters/[serial]/string/[1-N]/power [serial]/[1-4]/power R DC power of specific input in watt Watt (W)
[dtuserial]/inverters/[serial]/string/[1-N]/voltage [serial]/[1-4]/voltage R DC voltage of specific input in volt Volt (V)
[dtuserial]/inverters/[serial]/string/[1-N]/yieldday [serial]/[1-4]/yieldday R Energy converted to AC per day on specific input Watt hours (Wh)
[dtuserial]/inverters/[serial]/string/[1-N]/yieldtotal [serial]/[1-4]/yieldtotal R Energy converted to AC since reset on specific input Kilo watt hours (kWh)
[dtuserial]/inverters/[serial]/string/[1-N]/maxpower R

Mapped to InfluxDB as measurement ("table") input:

dtu inverter string field value timestamp
[dtuserial] [serial] [1-N] ... ... ...

Valid fields: current | name | irridiation | power | voltage | yieldday | yieldtotal

Topics to set values

Topic(new) Topic R / W Description Value / Unit
[dtuserial]/inverters/[serial]/cmd/limit_persistent_relative [serial]/cmd/limit_persistent_relative W Set the inverter limit as a percentage of total production capability. The value will survive the night without power. The updated value will show up in the web GUI and limit_relative topic immediatly. %
[dtuserial]/inverters/[serial]/cmd/limit_persistent_absolute [serial]/cmd/limit_persistent_absolute W Set the inverter limit as a absolute value. The value will survive the night without power. The updated value will set immediatly within the inverter but show up in the web GUI and limit_relative topic after around 4 minutes. If you are using a already known inverter (known Hardware ID), the updated value will show up within a few seconds. Watt (W)
[dtuserial]/inverters/[serial]/cmd/limit_nonpersistent_relative [serial]/cmd/limit_nonpersistent_relative W Set the inverter limit as a percentage of total production capability. The value will reset to the last persistent value at night without power. The updated value will show up in the web GUI and limit_relative topic immediatly. The value must be published non-retained, otherwise it will be ignored! %
[dtuserial]/inverters/[serial]/cmd/limit_nonpersistent_absolute [serial]/cmd/limit_nonpersistent_absolute W Set the inverter limit as a absolute value. The value will reset to the last persistent value at night without power. The updated value will set immediatly within the inverter but show up in the web GUI and limit_relative topic after around 4 minutes. If you are using a already known inverter (known Hardware ID), the updated value will show up within a few seconds. The value must be published non-retained, otherwise it will be ignored! Watt (W)
[dtuserial]/inverters/[serial]/cmd/power [serial]/cmd/power W Turn the inverter on (1) or off (0) 0 or 1
[dtuserial]/inverters/[serial]/cmd/restart [serial]/cmd/restart W Restarts the inverters (also resets YieldDay) 1

Not mapped to InfluxDB!