impac_private_dict = {
0x30091001: ("FL", "1", "Measured Distal Target Distance", ""), # noqa
0x30091002: ("FL", "1", "Specified Primary Ambient Meterset", ""), # noqa
0x30091003: ("FL", "1", "Delivered Primary Ambient Meterset", ""), # noqa
0x30091004: ("FL", "1", "Current Temperature", ""), # noqa
0x30091005: ("FL", "1", "Current Pressure", ""), # noqa
0x30091006: ("FL", "1", "TP Correction Factor", ""), # noqa
0x30091007: ("FL", "1", "Measured Uncollimated Field Diameter", ""), # noqa
0x30091008: ("FL", "1", "Measured SOBP Width", ""), # noqa
0x30091010: ("FL", "1", "Table Top Vertical Correction", ""), # noqa
0x30091011: ("FL", "1", "Table Top Longitudinal Correction", ""), # noqa
0x30091012: ("FL", "1", "Table Top Lateral Correction", ""), # noqa
0x30091013: ("FL", "1", "Patient Support Angle Correction", ""), # noqa
0x30091014: ("FL", "1", "Patient Support Pitch Angle Correction", ""), # noqa
0x30091015: ("FL", "1", "Patient Support Roll Angle Correction", ""), # noqa
0x30091016: ("IS", "1", "Number of Paintings Fully Delivered", ""), # noqa
0x30091017: ("IS", "1", "Treatment Termination Scan Spot Index", ""), # noqa
0x30091047: ("FL", "2-n", "Line Scan Metersets Delivered", ""), # noqa
0x300B1001: ("FL", "1", "Distal Target Distance Tolerance", ""), # noqa
0x300B1002: ("FL", "1", "Maximum Collimated Field Diameter", ""), # noqa
0x300B1003: ("CS", "1", "Beam Check Flag", ""), # noqa
0x300B1004: ("FL", "1", "Planned Distal Target Distance", ""), # noqa
0x300B1005: ("CS", "1", "Treatment Delivery Status", ""), # noqa
0x300B1006: ("CS", "1", "Treatment Machine Mode", ""), # noqa
0x300B1007: ("CS", "1", "Position Correction Flag", ""), # noqa
0x300B1008: ("SH", "1", "Beam Line Data Table Version", ""), # noqa
0x300B1009: ("CS", "1", "Respiratory Gating Flag", ""), # noqa
0x300B100A: ("FL", "1", "Respiratory Gating Cycle", ""), # noqa
0x300B100B: ("FL", "1", "Flat Top Length", ""), # noqa
0x300B100C: ("FL", "1", "Spill Length", ""), # noqa
0x300B100D: ("FL", "1", "Uncollimated Field Diameter Tolerance", ""), # noqa
0x300B100E: ("FL", "1", "Nominal SOBP Width", ""), # noqa
0x300B1011: ("FL", "1", "Nominal SOBP Width Tolerance", ""), # noqa
0x300B1012: ("FL", "1", "TP Corrected Meterset Tolerance", ""), # noqa
0x300B1013: ("IS", "1", "Number of Pieces", ""), # noqa
0x300B1014: ("FL", "1-n", "Change Check Data Before", ""), # noqa
0x300B1015: ("FL", "1-n", "Change Check Data After", ""), # noqa
0x300B1016: ("FL", "1", "Beam Intensity", ""), # noqa
0x300B1017: ("FL", "1", "Peak Range", ""), # noqa
0x300B1018: ("DS", "1", "Planned Patient Support Angle", ""), # noqa
0x300B101A: ("FL", "1", "Planned Table Top Roll Angle", ""), # noqa
0x300B1020: ("DS", "2", "Respiratory Phase Gating Duty Cycle", ""), # noqa
0x300B1090: ("SH", "2", "Line Spot Tune ID", ""), # noqa
0x300B1092: ("IS", "1", "Number of Line Scan Spot Positions", ""), # noqa
0x300B1094: ("FL", "2-n", "Line Scan Position Map", ""), # noqa
0x300B1096: ("FL", "2-n", "Line Scan Meterset Weights", ""), # noqa
0x300B1098: ("FL", "2", "Line Scanning Spot Size", ""), # noqa
0x300B109A: ("IS", "1", "Number of Line Scan Paintings", ""), # noqa
}