Consider making i_x
and i_xx
SAPM parameters optional
#2402
Labels
Milestone
i_x
and i_xx
SAPM parameters optional
#2402
Is your feature request related to a problem? Please describe.$I_x$ and $I_{xx}$ points in addition to the usual SC/OC/MP points. These require additional parameters which may be hard to determine, as these points are not included in module characterization methodologies like IEC 61853-1. They are also not very useful; applications requiring such intermediate points are probably better off using a SDM.
The SAPM DC model produces what it calls the
Describe the solution you'd like$I_x$ and $I_{xx}$ parameters (
Make the
IXO
,IXXO
,C4
,C5
,C6
,C7
) optional inpvlib.pvsystem.sapm
, and any higher-level wrappers likeModelChain
.Describe alternatives you've considered
N/A
Additional context
#2393 (comment)
The text was updated successfully, but these errors were encountered: