%% PS2000Constants
%
% The PS2000Constants class defines a number of constant values that
% can be used to define the properties of an Oscilloscopes device or
% for passing as parameters to function calls.
%
% The properties in this file are divided into the following
% sub-sections:
%
% * Timebases
% * ETS Mode Properties
% * Analogue offset values
% * Maximum/Minimum Waveform Frequencies
% * Function/Arbitrary Waveform Parameters
% * Maximum and minimum ADC count values
% * PicoScope 2000 Series Models using this driver
%
% Ensure that the location of this class file is on the MATLAB Path.
%
% Copyright: © 2013-2017 Pico Technology Ltd. All rights reserved.
classdef PS2000Constants
properties (Constant)
PS2000_MAX_TIMEBASE = 19;
PS2105_MAX_TIMEBASE = 20;
PS2104_MAX_TIMEBASE = 19;
PS2200_MAX_TIMEBASE = 23;
PS2000_MAX_OVERSAMPLE = 256;
PS2105_MAX_ETS_CYCLES = 250;
PS2105_MAX_ETS_INTERLEAVE = 50;
PS2104_MAX_ETS_CYCLES = 125;
PS2104_MAX_ETS_INTERLEAVE = 25;
PS2203_MAX_ETS_CYCLES = 250;
PS2203_MAX_ETS_INTERLEAVE = 50;
PS2204_MAX_ETS_CYCLES = 250;
PS2204_MAX_ETS_INTERLEAVE = 40;
PS2205_MAX_ETS_CYCLES = 250;
PS2205_MAX_ETS_INTERLEAVE = 40;
PS2000_MIN_ETS_CYCLES_INTERLEAVE_RATIO = 1;
PS2000_MAX_ETS_CYCLES_INTERLEAVE_RATIO = 10;
PS2000_MIN_SIGGEN_FREQ = single(0.0);
PS2000_MAX_SIGGEN_FREQ = single(100000.0);
PS2000_MIN_SIGGEN_OFFSET_MV = -2000; % -2 Volts
PS2000_MAX_SIGGEN_OFFSET_MV = 2000; % +2 Volts
PS2000_MIN_SIGGEN_PKTOPK_MV = 0; % 0
PS2000_MAX_SIGGEN_PKTOPK_MV = 4000; % +/- 2 Volts
PS2000_SIGGEN_ZERO_VOLTAGE_DC = 0;
PS2000_AWG_DDS_FREQUENCY = 48e6; % DDS Frequency of 48MHz.
% Although the PS2000 uses an 8-bit ADC, it is usually possible to
% oversample (collect multiple readings at each time) by up to 256.
% the results are therefore ALWAYS scaled up to 16-bits, even if
% oversampling is not used.
%
% The maximum and minimum values returned are therefore as follows:
PS2000_MAX_VALUE = 32767;
PS2000_MIN_VALUE = -32767;
PS2000_LOST_DATA = -32768;
MAX_CHANNELS = 4;
% PicoScope Models
MODEL_NONE = 'NONE';
MODEL_PS2104 = '2104';
MODEL_PS2105 = '2105';
MODEL_PS2202 = '2202';
MODEL_PS2203 = '2203';
MODEL_PS2204 = '2204';
MODEL_PS2205 = '2205';
MODEL_PS2204A = '2204A';
MODEL_PS2205A = '2205A';
end