Hi @pueroman, If you could provide a couple of data files with Stages power meter data included, that would make development / testing much easier for me (otherwise we'll just have to do the "try this" ... "didn't quite work" ... "try this one instead" cycle, which can be quite a bit slower). Ideally, you would provide data files that you don't mind making public (eg not a ride to/from your house?), in which case I'll include them in Bipolar's unit tests. But I can still use them for testing even if you don't want to make them public. To provide the data files, pick / record a session on flow.polar.com, look at the session number in the URL, then find all of the files in the export directory (eg Also, it sometimes helps if you make the corresponding activity public on flow.polar.com, just so I can compare the Bipolar outputs against whatever flow.polar.com is saying, but that isn't necessary. Cheers. |
Hi @pueroman, I got your test data via email. Thanks 😄 At a glance it looks good (ie it is valid Protocol Buffers data). Hopefully I'll get a chance to play with it this weekend 😄 Are you happy for me to include the test data in the Bipolar project's test data suite? (https://github.com/pcolby/bipolar/tree/master/test/polar/v2/testdata) That way it would be included in automated tests that run every time code is pushed to github (and when running tests locally). This isn't necessary, but does reduce the chance of whatever fixes I implement being broken some time in the future. I can still fix the issue without adding the data to the tests, so just let me know if you're happy for me to do so or not. Cheers. |
Hi, |
Ok great. I'll leave out the |
This includes data from a Stages Power meter, which the V800 only records on one side, resulting in Bipolar reporting incorrect power values (issue #57). This data will soon be used to test / prove the fixes to that issue. Note, this is a verbatim copy of a sub-set of data provided by @pueroman - specifically, the `*-route` and `*-finalize` data files have been omitted (neither are necessary for fixing issue #57).
This includes the "expected" outputs which exhibit the existing issue. The next change(s) should fix the issue, and show the difference that the fix introduces into the generated data.
Specifically, as the V800 only reports power for the left side when using Stages power meters, the total output power samples ought to be doubled. Note, this implementation has a positive side-effect of causing 0-value power samples to be included in the generated TCX files, where previously such samples where being erroneously discarded as "no data".
Specifically, as the V800 only reports power for the left side when using Stages power meters, the total output power samples ought to be doubled.
@pueroman, this is probably fixed now... the TCX output seems right (as loaded into Strava), but I don't have access to PPT right now (not near my Windows machine) to test the HRM ouput. I haven't yet set the HRM pedalling index, since that goes against the HRM spec. But it wouldn't be the first time PPT 5 needed something against the spec, so I'll enable that if testing shows its still needed. If you're keen, you can test the generated TCX and/or HRM output via the unit test output files:
Or if you happen to use Windows, you can try the latest build from AppVeyor (the Windows automated build system I use for Bipolar):
I should be able to test against PPT 5 later in the week. Then I'll look at doing an official release for Windows and OSX. Cheers. |
Did a quick test with PPT 5 (release 5.41.002). |
Righto. I'll enable the Power Pedalling Index |
We do this any time power data is available, even though we get no such pedalling index data from the V800. This is being done for PPT5's benefit (does anyone use HRM files with anything else?).
Done. You should be able to test latest file(s) from the same URL(s). Otherwise I'll take a look on the weekend. Cheers. |
Been able to do the tests today. Everything seems to be fine now. Also compared data with tcx file in golden cheetah. No errors found. |
That's great news! 😄 I'm going to update the Flow Sync hook for issue #60 and then do a release. |
When using Stages power meter instead polar or srm only one side of power (left power) is distributed.
Two problems when exporting to hrm-file:
d) Power = 1
e) Power Left Right Balance = 1
f) Power Pedalling Index = 1
(don't know why, but tested it with different files)
"currentPower = currentPowerLeft * 2" (checked by comparing with tcx-export from polar flow web)