VO000960RWUEV disk in stormfly-03 should be replaced as it is approaching wearout.
sudo smartctl -a /dev/sg1 -d cciss,3
=== START OF INFORMATION SECTION ===
Vendor: HPE
Product: VO000960RWUEV
Revision: HPD8
Compliance: SPC-4
User Capacity: 960,197,124,096 bytes [960 GB]
Logical block size: 512 bytes
Physical block size: 4096 bytes
LU is resource provisioned, LBPRZ=1
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
Logical Unit id: 0x58ce38ee2152c175
Serial number: 21J0A0C2TDBR
Device type: disk
Transport protocol: SAS (SPL-4)
Local Time is: Fri Jan 10 11:06:00 2025 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
Temperature Warning: Enabled
=== START OF READ SMART DATA SECTION ===
SMART Health Status: OK
Percentage used endurance indicator: 80%
Current Drive Temperature: 36 C
Drive Trip Temperature: 60 C
Accumulated power on time, hours:minutes 32319:16
Manufactured in week 07 of year 2021
Elements in grown defect list: 0
Error counter log:
Errors Corrected by Total Correction Gigabytes Total
ECC rereads/ errors algorithm processed uncorrected
fast | delayed rewrites corrected invocations [10^9 bytes] errors
read: 0 0 0 0 0 911110.608 0
write: 0 0 0 0 0 1415325.967 0
verify: 0 0 0 0 0 0.000 0
Non-medium error count: 640179