Notifications
You must be signed in to change notification settings - Fork 2
/
check_smart_all_disks
executable file
·145 lines (125 loc) · 4.27 KB
/
check_smart_all_disks
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
#!/bin/bash
# $Id: check_smart_all_disks,v 1.23 2014/03/10 10:48:06 oernii Exp $
[[ $(id -u) -ne 0 ]] && echo "$0 needs to run as root to read SMART data." && exit 3
DEVS=`find /dev/disk/by-id/ -iname '*ata*' -and -not -iname '*part*' -and -not -iname '*QEMU_DVD-ROM*' -ls | gawk '{print $13}' | cut -f3 -d/ | sed -e 's/\(.*\)/\/dev\/\1/'|sort -u`
DEVS=`echo $DEVS`
if [ -f /etc/nagios/check_smart_devs ]
then
. /etc/nagios/check_smart_devs
# Example for SATA disks on MeraRaid
# DEVS="/dev/sda /dev/sdb /dev/sdc /dev/sdd /dev/sde /dev/sdf /dev/sdg /dev/sdh"
# Example for cciss devices:
# DEVS=/dev/disk/by-id/scsi-3600508b1001ca3f8143d49dd19bd2e1d
# DEVS="$DEVS /dev/disk/by-id/scsi-3600508b1001ca3f8143d49dd19bd2e1d"
# DEVS="$DEVS /dev/disk/by-id/scsi-3600508b1001ca3f8143d49dd19bd2e1d"
# DEVS="$DEVS /dev/disk/by-id/scsi-3600508b1001ca3f8143d49dd19bd2e1d"
# DEVS="$DEVS /dev/disk/by-id/scsi-3600508b1001ca3f8143d49dd19bd2e1d"
# DEVS="$DEVS /dev/disk/by-id/scsi-3600508b1001ca3f8143d49dd19bd2e1d"
# DEVS="$DEVS /dev/disk/by-id/scsi-3600508b1001ca3f8143d49dd19bd2e1d"
# DEVS="$DEVS /dev/disk/by-id/scsi-3600508b1001ca3f8143d49dd19bd2e1d"
#
# RAIDDEVS=8
# RAIDTYPE=cciss
fi
#DEVS=/dev/sda
OUT=`mktemp`
ERRORDEVICES=''
NAGIOS_OUTPUT=`mktemp`
SMARTCTL=smartctl
function check_ata_error_count()
{
$SMARTCTL --quietmode=errorsonly --log=error $1 > $OUT
if [[ `cat $OUT | wc -l` -eq 0 ]]
then
echo 0
else
echo "" >> $NAGIOS_OUTPUT
echo "ATA Error log: $1 [$devcnt]" >> $NAGIOS_OUTPUT
cat $OUT >> $NAGIOS_OUTPUT
NUM=`cat $OUT | grep 'ATA Error Count:'| sed -e 's/^ATA Error Count: \([0-9]\+\) .*/\1/g'`
#device_info $1
echo $NUM
fi
}
function check_health()
{
RET=`$SMARTCTL -H $1 | grep -vq ": PASSED"`
echo $?
}
function check_attribute()
{
LINE=`$SMARTCTL -A $1 | grep "$2"`
RET=`echo $LINE | gawk '{print $10}'`
if [[ $RET -gt 0 ]]
then
echo "" >> $NAGIOS_OUTPUT
echo $1 [$devcnt] $LINE >> $NAGIOS_OUTPUT
#device_info $1 >> $NAGIOS_OUTPUT
fi
echo $RET
}
function device_info()
{
echo ""
echo $1 [$devcnt]
$SMARTCTL -a $1 | egrep "Device Model|Serial Number|User Capacity|Power_On_Hours"
}
if [ -z "$DEVS" ]
then
echo "OK, No ATA/SATA devices found (virtual? hw-raid?)"
/bin/rm $OUT $NAGIOS_OUTPUT
exit 0
fi
let devcnt=0
for dev in $DEVS
do
if [[ x$RAIDTYPE != "x" ]]
then
SMARTCTL="smartctl --device=$RAIDTYPE,$devcnt"
fi
errors=`check_ata_error_count $dev`
health=`check_health`
attr1=`check_attribute $dev "Offline_Uncorrectable"`
attr2=`check_attribute $dev "Reported_Uncorrect"`
#attr3=`check_attribute $dev "Seek_Error_Rate"`
#attr4=`check_attribute $dev "UDMA_CRC_Error_Count"`
#attr5=`check_attribute $dev "Hardware_ECC_Recovered"`
attr6=`check_attribute $dev "Reallocated_Sector_Ct"`
attr7=`check_attribute $dev "Current_Pending_Sector"`
#attr8=`check_attribute $dev "Media_Wearout_Indicator"`
attr9=`check_attribute $dev "End-to-End_Error"`
let RESULTS[$devcnt]=0
if [ ! -z $errors ]; then let RESULTS[$devcnt]=${RESULTS[$devcnt]}+$errors; fi
if [ ! -z $health ]; then let RESULTS[$devcnt]=${RESULTS[$devcnt]}+$health; fi
if [ ! -z $attr1 ]; then let RESULTS[$devcnt]=${RESULTS[$devcnt]}+$attr1; fi
if [ ! -z $attr2 ]; then let RESULTS[$devcnt]=${RESULTS[$devcnt]}+$attr2; fi
#if [ ! -z $attr3 ]; then let RESULTS[$devcnt]=${RESULTS[$devcnt]}+$attr3; fi
#if [ ! -z $attr4 ]; then let RESULTS[$devcnt]=${RESULTS[$devcnt]}+$attr4; fi
#if [ ! -z $attr5 ]; then let RESULTS[$devcnt]=${RESULTS[$devcnt]}+$attr5; fi
if [ ! -z $attr6 ]; then let RESULTS[$devcnt]=${RESULTS[$devcnt]}+$attr6; fi
if [ ! -z $attr7 ]; then let RESULTS[$devcnt]=${RESULTS[$devcnt]}+$attr7; fi
#if [ ! -z $attr8 ]; then let RESULTS[$devcnt]=${RESULTS[$devcnt]}+$attr8; fi
if [ ! -z $attr9 ]; then let RESULTS[$devcnt]=${RESULTS[$devcnt]}+$attr9; fi
if [[ ${RESULTS[$devcnt]} -gt 0 ]]
then
ERRORDEVICES="$ERRORDEVICES $dev [$devcnt]"
fi
let TOTAL=$TOTAL+${RESULTS[$devcnt]}
let devcnt++
done
if [[ $TOTAL -gt 0 ]];
then
echo "WARNING: SMART Errors found on disks $ERRORDEVICES [TOTAL: $TOTAL]"
cat $NAGIOS_OUTPUT
echo ""
echo "Device info:"
for disk in `cat $NAGIOS_OUTPUT | grep ^/dev | cut -f1 -d" " | sort -u`
do
device_info $disk
done
/bin/rm $OUT $NAGIOS_OUTPUT
exit 1
else
/bin/rm $OUT $NAGIOS_OUTPUT
echo "OK, no SMART errors found on $DEVS"
fi