Set port-group uplink to enhanced LAG when configured in nested VMware setups

Table of contents

Overview

VMware vSphere DVS >= 6.6.0 requires enhanced LAG always and acc-provision tool doesn't set port-group uplink to enhanced LAG when configured in nested VMware setup.

When provisioning ACI K8S configuration using acc-provision in a nested VMware environment, if the DVS uplink policy is configured with enhanced LAG, there will be connectivity issue between the k8s nodes and ACI. This is due to acc-provision script not configuring the proper Teaming and Failover policies on the DVS port-group.

Workaround : manually configure the eLag policy on the port-group pushed by the APIC.

  1. On vSphere, go to Networking -> {your DVS} -> {k8s port-group}
  2. Go to Configure -> Policies, click edit
  3. Under "Teaming and Failover" move the eLag policy to the Active Uplink and lower the other Uplinks to the Inactive Uplink

Mechanism

Add following configuration in the acc provision input file:

aci_config::
  vmm_domain:
    nested_inside
      elag_name: "fab-elag"  # elag name on APIC, this is required for ESXi vDS >= 6.6.0

Run acc-provision tool on updated acc provision input file

acc-provision -a -c <acc_provision_input_file> -f <flavor> -u <apic_username> -p <apic_password> -o aci_deployment.yaml

When elag_name is configured in acc provision input, now we are adding enhaced LAG policy to the Custom Trunk Port Group and also for vmm-vmware domain attachment under aci-containers-node EPG. This setting is set per port-group and consistently set for both Port-Groups.