DUT stuck in Configuration Idle #74

Open
LobnaTarek opened this issue Jul 19, 2021 · 1 comment
Open

DUT stuck in Configuration Idle #74

LobnaTarek opened this issue Jul 19, 2021 · 1 comment
Assignees
Labels
Design Issue regarding the design team implementation issues

Comments

@LobnaTarek
Copy link
Collaborator

When environment is downstream the DUT stuck in the Configuration Idle state and remain sending idle data even after the environment received 8 consecutive idle data and sent 16 idle data after receiving 1 idle data, so as they don't transition to L0, the pl_linkup is not asserted which inform other device that linkup finished.

Parameters:
DUT is acting as upstream.
Width = 8.

image

@LobnaTarek LobnaTarek added the Design Issue regarding the design team implementation issues label Jul 19, 2021
@mohammedBadawi mohammedBadawi added the Fixed and awaits validation The issue is fixed and waits for the verification team to close the issue label Jul 20, 2021
@mohammedBadawi
Copy link
Collaborator

please validate

@ibrahemkhafaga ibrahemkhafaga removed the Fixed and awaits validation The issue is fixed and waits for the verification team to close the issue label Jul 21, 2021
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment