edid-decode (hex):
00 ff ff ff ff ff ff 00 06 af 7b 17 00 00 00 00
01 11 01 03 80 21 15 78 0a 87 f5 94 57 4f 8c 27
27 50 54 00 00 00 01 01 01 01 01 01 01 01 01 01
01 01 01 01 01 01 7c 2e 90 a0 60 1a 1e 40 30 20
36 00 4b cf 10 00 00 19 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 fe 00 4a
54 33 33 31 00 42 31 35 34 53 57 31 00 00 00 fe
00 2a 3a 45 4d 6c 8b b1 ff 02 01 0a 20 20 00 e0
----------------
Block 0, Base EDID:
EDID Structure Version & Revision: 1.3
Vendor & Product Identification:
Manufacturer: AUO
Model: 6011
Made in: week 1 of 2007
Basic Display Parameters & Features:
Digital display
Maximum image size: 33 cm x 21 cm
Gamma: 2.20
RGB color display
First detailed timing is the preferred timing
Color Characteristics:
Red : 0.5800, 0.3398
Green: 0.3095, 0.5498
Blue : 0.1552, 0.1552
White: 0.3134, 0.3291
Established Timings I & II: none
Standard Timings: none
Detailed Timing Descriptors:
DTD 1: 1680x1050 59.883253 Hz 16:10 64.674 kHz 119.000000 MHz (331 mm x 207 mm)
Hfront 48 Hsync 32 Hback 80 Hpol N
Vfront 3 Vsync 6 Vback 21 Vpol N
Empty Descriptor
Alphanumeric Data String: 'JT331'
Alphanumeric Data String: '*:EMl'
Checksum: 0xe0
----------------
Warnings:
Block 0, Base EDID:
Detailed Timing Descriptor #1: DTD is similar but not identical to DMT 0x39.
Failures:
Block 0, Base EDID:
Empty Descriptor: Use Dummy Descriptor instead of all zeroes.
Alphanumeric Data String: Non-printable character.
Alphanumeric Data String: Non-printable character.
Missing Display Product Name.
Missing Display Range Limits Descriptor.
EDID conformity: FAIL