# Tutorial for this video: https://www.youtube.com/watch?v=EA2pytl3MKg
import pandapower as pp
import pandapower.plotting as pplt
def faulty_example_network():
net = pp.create_empty_network()
pp.create_bus(net, name="110 kV bar", vn_kv=110, type='b', in_service='True')
pp.create_bus(net, name="20 kV bar", vn_kv=20, type='b')
pp.create_bus(net, name="bus 2", vn_kv=30, type='b')
pp.create_bus(net, name="bus 3", vn_kv=20, type='b')
pp.create_bus(net, name="bus 4", vn_kv=20, type='b')
pp.create_bus(net, name="bus 5", vn_kv=-20, type='b')
pp.create_bus(net, name="bus 6", vn_kv=20, type='b')
pp.create_ext_grid(net, 0, vm_pu=1)
pp.create_line(net, name="line 0", from_bus=1, to_bus=2, length_km=0, std_type="NAYY 4x150 SE")
pp.create_line(net, name="line 1", from_bus=2, to_bus=3, length_km=1, std_type="NAYY 4x150 SE")
pp.create_line(net, name="line 2", from_bus=3, to_bus=4, length_km=1, std_type="NAYY 4x150 SE")
pp.create_line(net, name="line 3", from_bus=4, to_bus=5, length_km=1, std_type="NAYY 4x150 SE")
pp.create_line(net, name="line 4", from_bus=5, to_bus=6, length_km=1, std_type="NAYY 4x150 SE")
pp.create_line(net, name="line 5", from_bus=6, to_bus=1, length_km=1, std_type="NAYY 4x150 SE")
pp.create_transformer_from_parameters(net, hv_bus=1, lv_bus=0, i0_percent=0.038, pfe_kw=11.6,
vkr_percent=0.322, sn_mva=40.0, vn_lv_kv=22.0,
vn_hv_kv=110.0, vk_percent=17.8)
pp.create_load(net, 2, p_mw=-1, q_mvar=0.200, name="load 0")
pp.create_load(net, 3, p_mw=1, q_mvar=0.200, name="load 1")
pp.create_load(net, 4, p_mw=1, q_mvar=0.200, name="load 2")
pp.create_load(net, 5, p_mw=1, q_mvar=0.200, name="load 3")
pp.create_load(net, 6, p_mw=1, q_mvar=0.200, name="load 4")
pp.create_switch(net, bus=1, element=0, et='l')
pp.create_switch(net, bus=2, element=0, et='l')
pp.create_switch(net, bus=2, element=1, et='l')
pp.create_switch(net, bus=3, element=1, et='l')
pp.create_switch(net, bus=3, element=2, et='l')
pp.create_switch(net, bus=4, element=2, et='l')
pp.create_switch(net, bus=4, element=3, et='l', closed=False)
pp.create_switch(net, bus=5, element=3, et='l')
pp.create_switch(net, bus=5, element=4, et='l', closed=False)
pp.create_switch(net, bus=6, element=4, et='l', closed=False)
pp.create_switch(net, bus=6, element=5, et='l')
pp.create_switch(net, bus=1, element=5, et='l')
return net
def diag():
net = faulty_example_network()
# pp.runpp(net)
# pplt.simple_plot(net, plot_line_switches=True)
pp.diagnostic(net)
if __name__ == "__main__":