AGC (Automatic Gain Control) of BK4819

Registers used by AGC

BK4819 Registers_V1.1.pdf

Register Default Description
REG_7E<15> 0 AGC fix mode:
1: Fix
0: Auto
REG_7E<14:12> 0b011 AGC fix index:
011: Max.

100: Min.
REG_7E<11:6> Signal strength indicator
(not in the docs, my interpretation)
REG_10<15:0> 0x0038 RX AGC Gain Table[0] (Index for max. to min.: 3, 2, 1, 0, -1)
<9:8>: LNA Gain Short
11: 0 dB; 10: -11 dB; 01: -16 dB; 00: -19 dB
<7:5>: LNA Gain
111: 0 dB; 110: -2 dB; 101: -4 dB; 100: -6 dB;
011: -9 dB; 010: -14 dB; 001: -19 dB; 000: -24 dB
<4:3>: MIXER Gain
11: 0 dB; 10: -3 dB; 01: -6 dB; 00: -8 dB
<2:0>: PGA Gain
111: 0 dB; 110: -3 dB; 101: -6 dB; 100: -9 dB;
011: -15 dB; 010: -21 dB; 001: -27 dB; 000: -33 dB
REG_11<15:0> 0x025a RX AGC Gain Table[1]
The description is the same as REG_10.
REG_12<15:0> 0x037b RX AGC Gain Table[2]
The description is the same as REG_10.
REG_13<15:0> 0x03de RX AGC Gain Table[3]
The description is the same as REG_10.
REG_14<15:0> 0x0000 RX AGC Gain Table[-1]
The description is the same as REG_10.
REG_49<13:7> 0x50 RF AGC high threshold, 1 dB/LSB
REG_49<6:0> 0x30 RF AGC low threshold, 1 dB/LSB
REG_7B<15:0> 0xae34 RSSI table
REG_7C<15:0> 0x8000 RSSI table

How it works

AGC fix index (3-bits signed integer, 0b111/0x7 is -1, values from 3 to -1) is an index in the RX AGC Gain Table. The LNA short, LNA, MIXER, PGA gains are setup according to the current value from the table item pointed by the index.

In fix mode the index is user configurable and doesn't change on its own.

In auto mode the RF chip compares the signal strength (REG_7E<11:6>) to the high and low thresholds (REG_49<13:7>, REG_49<6:0>). If signal is higher than "high threshold" it decreases the AGC fix index, if it is lower than "low threshold" then it increases it. This way it tries to keep the signal strength between given threshold levels, thus preventing distortion and clipping.

This is in theory. In practice there are some issues. At least in AM mode it doesn't work as it should. Lets assume we have a very strong signal. AGC is in fix mode, index is set to 3, and value at index 3 is set to 0. The RSSI (read from other register) is around 170.
When auto mode is activated (default values in gains table) the index goes to -1, gains at index -1 are 0, so we should get 170 as before. Instead we get RSSI over 300. All of this can be simulated using another radio, even if it only transmits in FM.

Register REG_7B<15:0> also plays some role. When it is set to 0x8420 the RSSI will go down to 170 in the fix mode. But if 0x318C value is used it won't.

Another thing, the index sometimes goes to -2 !!??

EDIT:

REG_7B and REG_7C are probably RSSI correction values for gain indexes 2 to -1. This probably has to be adjusted so switching gain index doesn't cause change in RSSI value for the same strength of signal. I was wrong about AGC not working correctly for AM. I didn't have AM transmitter at the time so I was looking at RSSI values. The RSSI corrections are applied when gain index changes, that is why I was getting different RSSI values when I was changing gains at index 3, compared to the same gain set at index -1. AGC for AM works, the downside is that there are only 4 gain steps compared to 40 or more steps in AM-fix. Volume of AM signal depends on its strength so the more granular adjustments of gains the better. Also the AGC adjustment tends to oscillate when signal is in between two ranges.

1o11 AM fix issue with strong signals

There is an issue with original implementation. AGC is turned on so it regulates the index. If strong signal is received the AGC will change the index to -1 before AM-fix can react. The AM-fix always modifies gain table at index 3, AGC is locked at -1, so the AM-fix will have no effect on actual gains settings, and the signal will be clipped. One person noticed that when it happens toggling monitor function instantly fixes the issue. This is because toggling monitor resets the AGC and it momentarily switches to index 3 which applies AM-fix gain settings, that brings down the signal strength and the AGC will stay on index 3. I fixed it by disabling AGC in AM mode.