ZME_FT Floor Thermostat

This describes the Z-Wave device ZME_FT, manufactured by Z-Wave.Me with the thing type UID of zwaveme_zmeft_00_000.

ZME_FT product image

The ZME_FT supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

No device information is provided in the database. Consider updating the database to improve the documentation.

Channels

The following table summarises the channels available for the ZME_FT -:

Channel Channel Id Category Item Type
Sensor (temperature) sensor_temperature Temperature Number:Temperature
Thermostat mode thermostat_mode Temperature Number
Setpoint (heating) thermostat_setpoint Temperature Number:Temperature
Setpoint (furnace) thermostat_setpoint Temperature Number:Temperature

Sensor (temperature)

Indicates the current temperature.

The sensor_temperature channel supports the Number:Temperature item and is in the Temperature category.

Thermostat mode

Sets the thermostat.

The thermostat_mode channel supports the Number item and is in the Temperature category. The following state translation is provided for this channel to the Number item type -:

Value Label
0 Off
1 Heat
2 Cool
3 Auto
4 Aux Heat
5 Resume
6 Fan Only
7 Furnace
8 Dry Air
9 Moist Air
10 Auto Changeover
11 Heat Economy
12 Cool Economy
13 Away

Setpoint (heating)

Sets the thermostat setpoint.

The thermostat_setpoint channel supports the Number:Temperature item and is in the Temperature category.

Setpoint (furnace)

Sets the thermostat setpoint.

The thermostat_setpoint channel supports the Number:Temperature item and is in the Temperature category.

Device Configuration

The following table provides a summary of the 7 configuration parameters available in the ZME_FT. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Boost Dry mode duration
2 Button mode
3 Basic mode
4 Temperature control interval
5 Maximum allowed temperature deviation
6 Maximal allowed temperature In all modes the thermostat will switch off heating until temperature drops below this limit. For wooden and laminate floor maximal allowed temperature is 27 degree. For tile and concrete floor maximal allowed temperature value is 45 degree.
10 Typical click timeout Typical time used to differenciate click from hold

Parameter 1: Boost Dry mode duration

Values in the range 0 to 1800 may be set.

The manufacturer defined default value is 1800.

This parameter has the configuration ID config_1_2 and is of type INTEGER.

Parameter 2: Button mode

The following option values may be configured -:

Value Description
0 Toggle Normal Heating / Off
1 Toggle Normal Heating / Energy Save
2 Toggle Boost Dry

The manufacturer defined default value is 0 (Toggle Normal Heating / Off).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Parameter 3: Basic mode

The following option values may be configured -:

Value Description
0 Toggle Normal Heating / Off
1 Toggle Normal Heating / Energy Save
2 Toggle Boost Dry
3 Set Normal Heating set point temperature (in 0.1 C units)
4 Switch on/off relay directly (only if Thermostat Mode is in Off state)

The manufacturer defined default value is 0 (Toggle Normal Heating / Off).

This parameter has the configuration ID config_3_1 and is of type INTEGER.

Parameter 4: Temperature control interval

Values in the range 1 to 60 may be set.

The manufacturer defined default value is 18.

This parameter has the configuration ID config_4_1 and is of type INTEGER.

Parameter 5: Maximum allowed temperature deviation

Values in the range 1 to 60 may be set.

The manufacturer defined default value is 30.

This parameter has the configuration ID config_5_1 and is of type INTEGER.

Parameter 6: Maximal allowed temperature

In all modes the thermostat will switch off heating until temperature drops below this limit. For wooden and laminate floor maximal allowed temperature is 27 degree. For tile and concrete floor maximal allowed temperature value is 45 degree.

Values in the range 20 to 55 may be set.

The manufacturer defined default value is 27.

This parameter has the configuration ID config_6_1 and is of type INTEGER.

Parameter 10: Typical click timeout

Typical time used to differenciate click from hold

Values in the range 1 to 100 may be set.

The manufacturer defined default value is 50.

This parameter has the configuration ID config_10_1 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The ZME_FT supports 1 association group.

Group 1: Group 1

Unsolicited notifications about thermostat mode and setpoint temperature changes

Association group 1 supports 10 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SENSOR_MULTILEVEL_V4
COMMAND_CLASS_THERMOSTAT_MODE_V1
COMMAND_CLASS_THERMOSTAT_SETPOINT_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_PROTECTION_V1
COMMAND_CLASS_NODE_NAMING_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_VERSION_V1