layout | title |
---|---|
documentation |
ZEN22 - ZWave |
{% include base.html %}
This describes the Z-Wave device ZEN22, manufactured by Zooz with the thing type UID of zooz_zen22_00_000
.
The device is in the category of Wall Switch, defining Any device attached to the wall that controls a binary status of something, for ex. a light switch.
The ZEN22 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
- Manual or remote on/off and dimming control from your mobile device or computer (when included to a Z-Wave gateway controller)
- Universal 3-way capability – works with existing 3-way switches as long as neutral is present
- Z-Wave Plus with improved 500 chip for faster and safer wireless communication
- Works with LED, CFL, and incandescent bulbs
- Remembers and restores on/off / brightness status after power failure
- Based on universal multilevel switch command class - supported by most Z-Wave controllers
- May be associated and grouped with other Z-Wave devices for advanced home automation
- Customizeable LED indicator
- Air-gap switch for added safety
- Modern paddle design
- Built-in Z-Wave signal repeater for a stronger, more reliable network
- Bring your Z-Wave gateway hub or controller as close to the switch as possible
- Put your Z-Wave controller into inclusion mode
- Tap the upper paddle of the switch 3 times very quickly to finalize the inclusion process
- A new dimming device will appear on your controller's device list
- Bring your Z-Wave gateway hub or controller as close to the switch as possible
- Put your Z-Wave controller into exclusion mode
- Tap the lower paddle of the switch 3 times very quickly to finalize the exclusion process
- The device will disappear from your controller's device list
The following table summarises the channels available for the ZEN22 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Dimmer | switch_dimmer | DimmableLight | Dimmer |
The brightness channel allows to control the brightness of a light. It is also possible to switch the light on and off.
The switch_dimmer
channel supports the Dimmer
item and is in the DimmableLight
category.
The following table provides a summary of the 3 configuration parameters available in the ZEN22. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Paddle Control | Choose Paddle Functionality |
2 | LED Indicator Control | Choose LED Functionality |
3 | Enable / Disable LED Indicator | Enable or disable the LED indicator |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
Choose Paddle Functionality
The following option values may be configured -:
Value | Description |
---|---|
0 | Upper paddle turns on, lower paddle turns off |
1 | Upper paddle turns off, lower paddle turns on |
The manufacturer defined default value is 1
(Upper paddle turns off, lower paddle turns on).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Choose LED Functionality
The following option values may be configured -:
Value | Description |
---|---|
0 | LED on when switch off, LED off when switch off |
1 | LED on when switch on, LED off when switch off |
The manufacturer defined default value is 0
(LED on when switch off, LED off when switch off).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Enable or disable the LED indicator
The following option values may be configured -:
Value | Description |
---|---|
0 | LED indicator is enabled |
1 | LED indicator is disabled |
The manufacturer defined default value is 0
(LED indicator is enabled ).
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The ZEN22 supports 1 association group.
The Lifeline association group reports device status to a hub and is not designed to control other devices directly. When using the Lineline group with a hub, in most cases, only the lifeline group will need to be configured and normally the hub will perform this automatically during the device initialisation.
Association group 1 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_MULTILEVEL_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1 | |
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1 | |
COMMAND_CLASS_ZWAVEPLUS_INFO_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_POWERLEVEL_V1 | |
COMMAND_CLASS_ASSOCIATION_V2 | |
COMMAND_CLASS_VERSION_V2 |