PAN08 roller shutter

This describes the Z-Wave device PAN08, manufactured by Zipato with the thing type UID of zipato_pan08_00_000.

The device is in the category of Blinds, defining Roller shutters, window blinds, etc..

PAN08 product image

The PAN08 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

Roller shutter micromodule

Inclusion Information

Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer.

Pressing Include button three times within 2 seconds will enter inclusion mode. 

Exclusion Information

Put the Z-Wave Controller in exclusion mode.

Pressing Include button three times within 2 seconds will enter exclusion mode.

Node ID has been excluded.

Channels

The following table summarises the channels available for the PAN08 -:

Channel Channel Id Category Item Type
Blinds Control blinds_control Blinds Rollershutter
Scene Number scene_number Number
Electric meter (kWh) meter_kwh Energy Number
Electric meter (amps) meter_current Energy Number
Electric meter (volts) meter_voltage Energy Number
Electric meter (watts) meter_watts Energy Number
Electric meter (power factor) meter_powerfactor Energy Number
Alarm alarm_general Door Switch

Blinds Control

Provides start / stop control of blinds.

The blinds_control channel supports the Rollershutter item and is in the Blinds category.

Scene Number

Triggers when a scene button is pressed.

The scene_number channel supports the Number item.

Electric meter (kWh)

Indicates the energy consumption (kWh).

The meter_kwh channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (amps)

Indicates the instantaneous current consumption.

The meter_current channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (volts)

Indicates the instantaneous voltage.

The meter_voltage channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (watts)

Indicates the instantaneous power consumption.

The meter_watts channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Electric meter (power factor)

Indicates the instantaneous power factor.

The meter_powerfactor channel supports the Number item and is in the Energy category. This is a read only channel so will only be updated following state changes from the device.

Alarm

Indicates if an alarm is triggered.

The alarm_general channel supports the Switch item and is in the Door category. This is a read only channel so will only be updated following state changes from the device.

The following state translation is provided for this channel to the Switch item type -:

Value Label
OFF OK
ON Alarm

Device Configuration

The following table provides a summary of the 4 configuration parameters available in the PAN08. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 Watt meter report interval (5s) Interval (x5 seconds) to send out watt meter report
2 KWH Meter Report Interval (10min) Interval (x10 minutes) to send out KWH Meter Report
3 Threshold for Load Caution (10mA) Threshold (x0.01A) of current for Load Caution
4 Threshold of KWh for Load Caution

Parameter 1: Watt meter report interval (5s)

Interval (x5 seconds) to send out watt meter report

Values in the range 1 to 32767 may be set.

The manufacturer defined default value is 720.

This parameter has the configuration ID config_1_2 and is of type INTEGER.

Parameter 2: KWH Meter Report Interval (10min)

Interval (x10 minutes) to send out KWH Meter Report

Values in the range 1 to 32767 may be set.

The manufacturer defined default value is 6.

This parameter has the configuration ID config_2_2 and is of type INTEGER.

Parameter 3: Threshold for Load Caution (10mA)

Threshold (x0.01A) of current for Load Caution

Values in the range 1 to 1100 may be set.

The manufacturer defined default value is 1100.

This parameter has the configuration ID config_3_2 and is of type INTEGER.

Parameter 4: Threshold of KWh for Load Caution

Values in the range 1 to 10000 may be set.

The manufacturer defined default value is 10000.

This parameter has the configuration ID config_4_2 and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The PAN08 supports 1 association group.

Group 1: Blind Control

Association group 1 supports 1 node.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V3
COMMAND_CLASS_SCENE_ACTIVATION_V1
COMMAND_CLASS_SCENE_ACTUATOR_CONF_V1
COMMAND_CLASS_METER_V3
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_ZWAVEPLUS_INFO_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_ALARM_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1