layout | title |
---|---|
documentation |
YRD220 - ZWave |
{% include base.html %}
This describes the Z-Wave device YRD220, manufactured by ASSA ABLOY with the thing type UID of yale_yrd220_00_000
.
The device is in the category of Lock, defining Devices whose primary pupose is locking something.
The YRD220 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is unable to participate in the routing of data from other devices.
To include the lock in a Z-Wave Network (taken from the installation manual:
- Touch the lock screen to activate
- Enter the master pin and press #
- Press 7, then #
- Press 1, then #
The lock will now be in inclusion mode.
To exclude the lock from a Z-Wave Network (taken from the installation manual:
- Touch the lock screen to activate
- Enter the master pin and press #
- Press 7, then #
- Press 3, then #
The lock will now be in exclusion mode.
The following table summarises the channels available for the YRD220 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Door Lock | lock_door | Door | Switch |
Alarm | alarm_general | Door | Switch |
Alarm Raw | alarm_raw | String | |
Battery Level | battery-level | Battery | Number |
Lock and unlock the door.
The lock_door
channel supports the Switch
item and is in the Door
category.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
ON | Locked |
OFF | Unlocked |
Indicates if an alarm is triggered.
The alarm_general
channel supports the Switch
item and is in the Door
category. This is a read only channel so will only be updated following state changes from the device.
The following state translation is provided for this channel to the Switch
item type -:
Value | Label |
---|---|
OFF | OK |
ON | Alarm |
Provides alarm parameters as json string.
The alarm_raw
channel supports the String
item. This is a read only channel so will only be updated following state changes from the device.
This channel sets, and provides the alarm state as a JSON string. It is designed for use in rules.
Represents the battery level as a percentage (0-100%). Bindings for things supporting battery level in a different format (e.g. 4 levels) should convert to a percentage to provide a consistent battery level reading.
The battery-level
channel supports the Number
item and is in the Battery
category.
The following table provides a summary of the 7 configuration parameters available in the YRD220. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | Audio Volume | Sets the volume level of the beeps and voice prompts |
2 | Auto Re-lock | When enabled, the unit will automatically re-lock |
3 | Re-lock Time | Time after unlocking that the device will lock |
4 | Wrong Code Entry Limit | The number of invalid tries before the lock shutdowns and sends an alarm |
5 | Language | Language used by the voice prompts |
7 | Shutdown Time | Number of times the device is locked out after the invalid retries are exceeded |
8 | Operating Mode | Sets if the unit operates normal, or disables keypad and Z-Wave lock/unlock |
Lock Timeout | Sets the time after which the door will auto lock |
Sets the volume level of the beeps and voice prompts 1 = Silent
2 = Low
3 = High The following option values may be configured -:
Value | Description |
---|---|
1 | Silent |
2 | Low |
3 | High |
The manufacturer defined default value is 3
(High).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
When enabled, the unit will automatically re-lock 0 = Off
255 = On The following option values may be configured -:
Value | Description |
---|---|
0 | Off |
255 | On |
The manufacturer defined default value is 0
(Off).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Time after unlocking that the device will lock
Values in the range 5 to 255 may be set.
The manufacturer defined default value is 30
.
This parameter has the configuration ID config_3_1
and is of type INTEGER
.
The number of invalid tries before the lock shutdowns and sends an alarm
Values in the range 1 to 7 may be set.
The manufacturer defined default value is 5
.
This parameter has the configuration ID config_4_1
and is of type INTEGER
.
Language used by the voice prompts 1 = English
2 = Spanish
3 = French The following option values may be configured -:
Value | Description |
---|---|
1 | English |
2 | Spanish |
3 | French |
The manufacturer defined default value is 1
(English).
This parameter has the configuration ID config_5_1
and is of type INTEGER
.
Number of times the device is locked out after the invalid retries are exceeded
Values in the range 1 to 255 may be set.
The manufacturer defined default value is 30
.
This parameter has the configuration ID config_7_1
and is of type INTEGER
.
Sets if the unit operates normal, or disables keypad and Z-Wave lock/unlock 0 = Normal
1 = Vacation Mode (User Codes Disabled)
2 = Privacy Mode (User Codes and ZWave Codes Disabled The following option values may be configured -:
Value | Description |
---|---|
0 | Normal |
1 | Vacation Mode |
2 | Privacy Mode |
The manufacturer defined default value is 0
(Normal).
This parameter has the configuration ID config_8_1
and is of type INTEGER
.
Sets the time after which the door will auto lock.
This parameter has the configuration ID doorlock_timeout
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The YRD220 supports 1 association group.
Alarm reports are sent out to all devices in the association group
Association group 1 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_DOOR_LOCK_LOGGING_V1 | |
COMMAND_CLASS_SCHEDULE_ENTRY_LOCK_V1 | |
COMMAND_CLASS_DOOR_LOCK_V1 | |
COMMAND_CLASS_USER_CODE_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_ALARM_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_PROTECTION_V1 | |
COMMAND_CLASS_LOCK_V1 | |
COMMAND_CLASS_BATTERY_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 | |
COMMAND_CLASS_TIME_V1 | |
COMMAND_CLASS_TIME_PARAMETERS_V1 | |
COMMAND_CLASS_SECURITY_V1 |
Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.