Skip to content

Latest commit

 

History

History
140 lines (86 loc) · 4.52 KB

tz68_0_0.md

File metadata and controls

140 lines (86 loc) · 4.52 KB
layout title
documentation
TZ68 - ZWave

{% include base.html %}

TZ68 Wall Plug

This describes the Z-Wave device TZ68, manufactured by TKB Home with the thing type UID of tkb_tz68_00_000.

The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.

TZ68 product image

The TZ68 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.

Overview

The TKB TZ68 is a switch plug that can be placed between a wall outlet and electric devices, plugged in by cord. It can switch all loads up to 3500 W. The device is IP 20 rated and can therefore only be used in dry environments.

Inclusion Information

To confirm Inclusion hit the button on the device.

Exclusion Information

To confirm Exclusion hit the button on the device.

Channels

The following table summarises the channels available for the TZ68 -:

Channel Channel Id Category Item Type
Switch switch_binary Switch Switch

Switch

Switch the power on and off.

The switch_binary channel supports the Switch item and is in the Switch category.

Device Configuration

The following table provides a summary of the 2 configuration parameters available in the TZ68. Detailed information on each parameter can be found in the sections below.

Param Name Description
1 LED Behavior defines the behavior of the blue LED
2 Memory function Memory function behaviour control.
Switch All Mode Set the mode for the switch when receiving SWITCH ALL commands

Parameter 1: LED Behavior

defines the behavior of the blue LED

The following option values may be configured -:

Value Description
0 blue indicates off (default)
1 blue indicates on

The manufacturer defined default value is 1 (blue indicates on).

This parameter has the configuration ID config_1_1 and is of type INTEGER.

Parameter 2: Memory function

Memory function behaviour control. Control whether or not the plug shall remember it's state after power has been taken away. The following option values may be configured -:

Value Description
0 do not remember
1 do remember state (default)

The manufacturer defined default value is 1 (do remember state (default)).

This parameter has the configuration ID config_2_1 and is of type INTEGER.

Switch All Mode

Set the mode for the switch when receiving SWITCH ALL commands.

The following option values may be configured -:

Value Description
0 Exclude from All On and All Off groups
1 Include in All On group
2 Include in All Off group
255 Include in All On and All Off groups

This parameter has the configuration ID switchall_mode and is of type INTEGER.

Association Groups

Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.

The TZ68 supports 1 association group.

Group 1: Group1

Association group info report command class Profile:General lifeline ( Profile MSB=0,Profile LSB=1) Association group name report command class Group 1:lifeline

Association group 1 supports 5 nodes.

Technical Information

Endpoints

Endpoint 0

Command Class Comment
COMMAND_CLASS_NO_OPERATION_V1
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1 Linked to BASIC
COMMAND_CLASS_SWITCH_ALL_V1
COMMAND_CLASS_CONFIGURATION_V1
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1
COMMAND_CLASS_ASSOCIATION_V1
COMMAND_CLASS_VERSION_V1

Documentation Links


Did you spot an error in the above definition or want to improve the content? You can contribute to the database here.