This describes the Z-Wave device TZ68, manufactured by TKB Home with the thing type UID of tkb_tz68_00_000
.
The device is in the category of Power Outlet, defining Small devices to be plugged into a power socket in a wall which stick there.
The TZ68 supports routing. This allows the device to communicate using other routing enabled devices as intermediate routers. This device is also able to participate in the routing of data between other devices in the mesh network.
The TKB TZ68 is a switch plug that can be placed between a wall outlet and electric devices, plugged in by cord. It can switch all loads up to 3500 W. The device is IP 20 rated and can therefore only be used in dry environments.
To confirm Inclusion hit the button on the device.
To confirm Exclusion hit the button on the device.
The following table summarises the channels available for the TZ68 -:
Channel | Channel Id | Category | Item Type |
---|---|---|---|
Switch | switch_binary | Switch | Switch |
Switch the power on and off.
The switch_binary
channel supports the Switch
item and is in the Switch
category.
The following table provides a summary of the 2 configuration parameters available in the TZ68. Detailed information on each parameter can be found in the sections below.
Param | Name | Description |
---|---|---|
1 | LED Behavior | defines the behavior of the blue LED |
2 | Memory function | Memory function behaviour control. |
Switch All Mode | Set the mode for the switch when receiving SWITCH ALL commands |
defines the behavior of the blue LED
The following option values may be configured -:
Value | Description |
---|---|
0 | blue indicates off (default) |
1 | blue indicates on |
The manufacturer defined default value is 1
(blue indicates on).
This parameter has the configuration ID config_1_1
and is of type INTEGER
.
Memory function behaviour control. Control whether or not the plug shall remember it's state after power has been taken away. The following option values may be configured -:
Value | Description |
---|---|
0 | do not remember |
1 | do remember state (default) |
The manufacturer defined default value is 1
(do remember state (default)).
This parameter has the configuration ID config_2_1
and is of type INTEGER
.
Set the mode for the switch when receiving SWITCH ALL commands.
The following option values may be configured -:
Value | Description |
---|---|
0 | Exclude from All On and All Off groups |
1 | Include in All On group |
2 | Include in All Off group |
255 | Include in All On and All Off groups |
This parameter has the configuration ID switchall_mode
and is of type INTEGER
.
Association groups allow the device to send unsolicited reports to the controller, or other devices in the network. Using association groups can allow you to eliminate polling, providing instant feedback of a device state change without unnecessary network traffic.
The TZ68 supports 1 association group.
Association group info report command class Profile:General lifeline ( Profile MSB=0,Profile LSB=1) Association group name report command class Group 1:lifeline
Association group 1 supports 5 nodes.
Command Class | Comment |
---|---|
COMMAND_CLASS_NO_OPERATION_V1 | |
COMMAND_CLASS_BASIC_V1 | |
COMMAND_CLASS_SWITCH_BINARY_V1 | Linked to BASIC |
COMMAND_CLASS_SWITCH_ALL_V1 | |
COMMAND_CLASS_CONFIGURATION_V1 | |
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V1 | |
COMMAND_CLASS_ASSOCIATION_V1 | |
COMMAND_CLASS_VERSION_V1 |